• 제목/요약/키워드: ParkingLot

Search Result 429, Processing Time 0.028 seconds

A Low Power Parking Management System for Intelligent Building (인텔리전트 빌딩을 위한 저 전력 주차관리 시스템)

  • Lee, Chang-Ki;Im, Hyung-Kyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1479-1485
    • /
    • 2012
  • The parking management system can increase driver's convenience with detailed parking information service in the parking lot. At the same time, parking management system consumes non-negligible electrical energy with large amount of sensors, displays and control modules. With the increase in the demand for green and sustainable building design all over the world, it becomes a meaningful issue for parking management system to reduce operating power. This paper presents the preliminary design and estimated results of a parking management system which is optimized to reduce the power consumption mainly on detectors and displays. The system design is based on pre-developed wireless parking detectors, Park Tile and Park Disk. The system has a number of parking space detectors, vehicle count detectors, information displays, guidance terminals and other control units. We have performed system architecture design, communication network design, parking information service scenario planning, battery life regulation and at last operating power estimation. The estimated operating power was 0.93KW per parking-slot, which is 20% of traditional systems. The estimated annual maintenance cost was 18% of traditional systems.

A Study on Understanding Parking Turnover through Parking Survey (주차 시설 현황 조사를 통한 주차 회전율 파악에 관한 연구)

  • Lee, Hyun-Chang;Shin, Seong-Yoon;Shin, Kwang-Seong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2645-2650
    • /
    • 2014
  • This paper researches on securing parking spaces and improving parking performance, by use of vehicle license plate investigation for average parking time and parking turnover ratio. Even though general surveys on vehicle license plate investigation are performed by the person, our survey is performed by the machine, CCTV. Unusually, our method checks average parking time and parking turnover ratio at time intervals of the survey. So, it is easy to check whether a parking lot is effectively used and its traffic flows smoothly or not. In our experiment, we exclude a method to recognize characters by use of 4-direction projection.

A Comparative Analysis of Path Planning and Tracking Performance According to the Consideration of Vehicle's Constraints in Automated Parking Situations (자율주차 상황에서 차량 구속 조건 고려에 따른 경로 계획 및 추종 성능의 비교 분석)

  • Kim, Minsoo;Ahn, Joonwoo;Kim, Minsung;Shin, Minyong;Park, Jaeheung
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.3
    • /
    • pp.250-259
    • /
    • 2021
  • Path planning is one of the important technologies for automated parking. It requires to plan a collision-free path considering the vehicle's kinematic constraints such as minimum turning radius or steering velocity. In a complex parking lot, Rapidly-exploring Random Tree* (RRT*) can be used for planning a parking path, and Reeds-Shepp or Hybrid Curvature can be applied as a tree-extension method to consider the vehicle's constraints. In this case, each of these methods may affect the computation time of planning the parking path, path-tracking error, and parking success rate. Therefore, in this study, we conduct comparative analysis of two tree-extension functions: Reeds-Shepp (RS) and Hybrid Curvature (HC), and show that HC is a more appropriate tree-extension function for parking path planning. The differences between the two functions are introduced, and their performances are compared by applying them with RRT*. They are tested at various parking scenarios in simulation, and their advantages and disadvantages are discussed by computation time, cross-track error while tracking the path, parking success rate, and alignment error at the target parking spot. These results show that HC generates the parking path that an autonomous vehicle can track without collisions and HC allows the vehicle to park with lower alignment error than those of RS.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Study on the Changes in Evapotranspiration according to the Decentralized Rainwater Management (분산식 빗물관리시설 적용에 따른 증발산 변화 연구)

  • Han, Young-Hae;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.12 no.5
    • /
    • pp.3-10
    • /
    • 2012
  • In this study, the influence of decentralized rainwater management over the changes in evapotranspiration was analyzed. The analysis method was obtained by establishing the decentralized rainwater management plan according to different scenarios, and subsequently examined evapotranspiration in the plan. Scenario 1 refers to the analysis of the existing situation, in which was 100% of a parking lot is asphalt pavement. In Scenario 2, the pavement of the parking surface in the parking lot is replaced with lawn blocks. In Scenario 3, some asphalt pavement was removed to establish a flower-bed type infiltration system to allow rainwater to permeate. In Scenario 4, infiltration and storage of rain water would be achieved by transforming the parking surface into lawn blocks, keeping the asphalt for the parking road while establishing a vegetation strip. The amount of evapotranspiration of the target site was analyzed with a water budget analysis program (CAT) using the 2001 meteorological data for each scenario According to the analysis values of S2 and S3, it was found that evapotranspiration is critically affected by the amount of area replaced with pervious area in the total target site. An energy equivalent to 680kWh is required for 1 ton of water to evaporate. Hence, it can be seen that the active inducement of evapotranspiration in urban area makes a positive contribution not only to heat island mitigation, but also to the small-scale water circulation process in a city.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

An Experimental Study on Material Property of Parking Zone Flooring Occupancy Surface Finishing Used to Environment-friendly.High-liquidity Ceramic Resin Mortar (친환경.고유동 세라믹 수지 모르타르를 이용한 주차장 바닥용 표면 마감의 재료적 특성에 관한 실험적 연구)

  • Lee, Sun-Gyu;Moon, You-Seok;Lee, Hyung-Jun;Lee, Wan-Hwi;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.829-832
    • /
    • 2008
  • Since the early 1980s, the building is dramatically higher increases. Therefore, the shortage of parking spaces as a social problem has been pointed out. The parking lot utilization of underground space is increasing by like this problem solving countermeasure. However, Most of the organic material is used for construction in the parking lot on the floor. The existing parking zone flooring occupancy surface finishing is harmful gases and environmental hormones cause of the worker. The study on the safety of the worker consider using environment-friendly?high-liquidity ceramic resin mortar materials to evaluate the characteristics and physical properties.

  • PDF

Stereo vision distance measurement algorithm using Laser point for Image processing based Automatic car-parking system (영상처리기반 자동주차 시스템을 위한 레이저 포인터를 이용한 스테레오 비전 거리측정 알고리즘)

  • Kim, Yoon-Ho;Lim, Myoung-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.373-376
    • /
    • 2007
  • As a part of automatic car parking, this paper have devised the distance measurement algorism using stereo vision system which measure between object and parking lot. In this simulation, laser pointer is used for detecting edge of designated object and real distance is measured by searching the position of laser pointer and measuring the distance. Which are 1 / 1.5 / 2 / 2.5 / 3m and adjusted correction had applied in order for use in car parking system.

  • PDF

A Study on Ventilation Performance driven by Wind Force in Underground Parking Lots of Apartment - Influence of Opening Size and Surrounding Building - (공동주택 지하주차장의 풍력환기 성능에 관한 연구 - 환기구 면적 및 주변건물의 영향 -)

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.29-34
    • /
    • 2012
  • As a series of studies about natural ventilation driven by wind in basement parking lots of apartment, the influence of opening size and surrounding buildings on ventilation rate was analyzed. Natural ventilation in underground parking lots almost rely on wind than temperature difference. To investigate natural ventilation driven by wind, wind tunnel tests by using scale model and tracer gas method were conducted. $CO_2$-gas concentration was measured, natural ventilation rates were calculated. The experimental results showed that the natural ventilation rate is more reliable to wind direction and surrounding building than opening size and distance between buildings. It was verified that surrounding buildings play a principal role in increasing air flow rate by accelerating wind speed, and growing turbulence intensity. And it showed that ventilation performance is able to be increased by oblique wind to entrance ramp than head on wind in underground parking lots with surrounding buildings.