• Title/Summary/Keyword: Park Evaluation

Search Result 16,398, Processing Time 0.042 seconds

Nondestructive Evaluation for Degraded 2.25Cr-1Mo Steel though Surface SH-wave (표면SH파를 이용한 2.25Cr-1Mo강의 열화.손상 평가)

  • Kim, Hyun-Mook;Park, Ik-Keun;Park, Un-Su;Ahn, Hyung-Keun;Kim, Chung-Soek
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.280-285
    • /
    • 2000
  • It is very important to evaluate the surface or subsurface microstructure because of their influences on mechanical properties of materials. Surface SH-wave which is horizontally polarized shear wave traveling along near surface and subsurface layer is an attractive technique for material evaluation. The destructive method is widely used for the estimation of material degradation but it has a great difficulty in preparing specimens from in-service industrial facilities. In this study, nondestructive evaluation for degraded structural materials used at high temperature though surface SH-wave method is discussed. 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $650^{\circ}$ were evaluated though ultrasonic nondestructive evaluation techniques investigating the change of sound velocity, attenuation coefficient and amplitude spectra. In addition, it has verified experimentally the frequency-dependence of attenuation coefficient though wavelet analysis method.

  • PDF

Development a Tool for Evaluating Nurses' Performance in Hospital Units (간호단위 성과평가도구 개발)

  • Park, Sung Ae;Kim, Jin Hyun;Park, Kwang Ok;Kim, Myoung Sook;Kim, Se Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.15 no.2
    • /
    • pp.5-21
    • /
    • 2009
  • Purpose: This study was aimed to develop a tool for evaluating nurses' performance by using Balanced Score Card (BSC) in hospital units. Methods: Preliminary survey was done in 10 hospitals to investigate evaluation criteria for nurses' performance. For the main study, each of 14 nursing managers evaluated 2 nursing units (total of 28 nursing units) to verify the sensitivity of the tool criteria. The evaluation result drawn from the preliminary BSC tool was analyzed to verify the sensitivity and validity of the tool. Results: As a result, nurses' performance evaluation tool consisted of 4 categories, 8 objectives, and 14 criteria was developed. Conclusion: The BSC tool for nurses' performance evaluation provides meaningful data in evaluating nursing performance in hospital units.

Evaluation Criteria of IT Business Value : The Difference Between Ex Ante and Post Implementation Evaluation (IT 비즈니스 가치 평가관점 : 사전-사후 평가시점 및 정보시스템 유형별 차이)

  • Park, So-Hyun;Lee, Kuk-Hie
    • Journal of Information Technology Applications and Management
    • /
    • v.15 no.1
    • /
    • pp.203-224
    • /
    • 2008
  • The purpose of this study is to investigate the evaluation perspectives of IT business value and empirically analyze the differences of evaluation perspectives between ex ante evaluation and post implementation evaluation, and among various information system types. 4 evaluation perspectives which have been used in the previous studies and in the field of industry practices are financial, customer, internal process, and growth, which are based on the BSC model. Data of 98 information systems have been collected from 89 companies including manufacturers, banks, insurances, and stock trading companies. As results of multi-way MANOVA test, 3 out of 8 hypothesis have been accepted statistically. While the order of importance of 4 perspectives in ex ante evaluation is customer, financial, internal process, and growth, the order of post implementation evaluation appears to be much different : that is, internal process, customer, financial, and growth. These findings provide insights for both IT practitioners and researchers.

  • PDF

Characteristics and Administration Method of Course Evaluation in Engineering Education (공학교육 강의 평가의 특성과 운영 방법에 대한 사례 연구)

  • Kim Young-Uk;Kim In-Taek;Park Kang;Park Yong-Won
    • Journal of Engineering Education Research
    • /
    • v.7 no.1
    • /
    • pp.64-73
    • /
    • 2004
  • Universities have to offer efficient education through measuring and evaluating courses precisely. Course evaluation gives instructors a chance of understanding quality and issues arisen in courses, and students a chance of the effective learning. This study investigates general characteristics and administration method of course evaluation in engineering education. The investigation includes elements of course evaluation, various evaluation methods, effective administration methods, and validation of the evaluation. A survey was undertaken to the students at Myongji University regarding course evaluation. The study summarized the results of the survey.

Rapid determination and quantification of hair-growth compounds in adulterated products by ultra HPLC coupled to quadrupole-orbitrap MS

  • Lee, Ji Hyun;Park, Han Na;Kang, Gihaeng;Kim, Nam Sook;Park, Seongsoo;Lee, Jongkook;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, a number of adulterated products, which are advertised as hair-growth enhancer have been emerged among those who suffer hair loss disease. For continuous control of illegal products, in this study, a rapid and sensitive method for simultaneous screening of 12 compounds that enhance hair-growth was established to protect public health by ultrahigh-performance liquid chromatography coupled to quadrupole-orbitrap mass spectrometry (UHPLC-Q-Orbitrap-MS). Fragmentation pathways of them were proposed based on $MS^2$ spectral data obtained using the established method. In this analysis, the LODs and LOQs ranged from 0.05 to 50 ng/mL and from 0.17 to 167 ng/mL, respectively. The square of the linear correlation coefficient ($R^2$) was determined as more than 0.995. The intra- and inter-assay accuracies were respective 88-112 % and 88-115 %. Their precision values were measured within 5 % (intra-day) and 10 % (inter-day). Mean recoveries of target compounds in adulterated products ranged from 84 to 115%. The relative standard deviation of stability was less than 12 % at $4^{\circ}C$ for 48 h. The method was employed to screen 14 dietary supplements advertised to be effective for the treatment of hair loss. Some of the products (~21 %) were proven to contain synthetic drugs that promote hair growth such as triaminodil, minoxidil, and finasteride.

Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

  • Lee, Ji Hyun;Cho, So-Hyun;Park, Han Na;Park, Hyoung Joon;Kim, Nam Sook;Park, Sung Kwan;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.171-178
    • /
    • 2018
  • Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell $120SB-C_{18}$ column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

Product elements for the safety assessment (안전성 평가를 위한 제품요소)

  • Park, Ji-Yong;Cho, Am
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.04a
    • /
    • pp.239-245
    • /
    • 2008
  • In this study has investigated and considered product planning methods at the existing product design process and being used the safety evaluation methods at the product planning stage, and has deduced the 16 safety evaluation elements to have to be considered for executing the safety evaluation at the product planning stage. When the safety evaluation is executed from the product planning stage, more safe products will be designed.

  • PDF

Development of a New Approach to Determine the Potency of Bacille Calmette-Guérin Vaccines Using Flow Cytometry

  • Gweon, Eunjeong;Choi, Chanwoong;Kim, Jaeok;Kim, Byungkuk;Kang, Hyunkyung;Park, Taejun;Ban, Sangja;Bae, Minseok;Park, Sangjin;Jeong, Jayoung
    • Osong Public Health and Research Perspectives
    • /
    • v.8 no.6
    • /
    • pp.389-396
    • /
    • 2017
  • Objectives: To circumvent the limitations of the current golden standard method, colony-forming unit (CFU) assay, for viability of Bacille Calmette-$Gu{\acute{e}}rin$ (BCG) vaccines, we developed a new method to rapidly and accurately determine the potency of BCG vaccines. Methods: Based on flow cytometry (FACS) and fluorescein diacetate (FDA) as the most appropriate fluorescent staining reagent, 17 lots of BCG vaccines for percutaneous administration and 5 lots of BCG vaccines for intradermal administration were analyzed in this study. The percentage of viable cells measured by flow cytometry along with the total number of organisms in BCG vaccines, as determined on a cell counter, was used to quantify the number of viable cells. Results: Pearson correlation coefficients of FACS and CFU assays for percutaneous and intradermal BCG vaccines were 0.6962 and 0.7428, respectively, indicating a high correlation. The coefficient of variation value of the FACS assay was less than 7%, which was 11 times lower than that of the CFU assay. Conclusion: This study contributes to the evaluation of new potency test method for FACS-based determination of viable cells in BCG vaccines. Accordingly, quality control of BCG vaccines can be significantly improved.