The Therapeutic Effects of an Early Exercise Program After Mastectomy (유방 절제술 후 조기 운동프로그램의 치료 효과)

  • Lee, Gyu-Wan;Yi, Chung-Hwi;Cho, Sang-Hyun;Park, Jung-Mi
    • Physical Therapy Korea
    • /
    • v.8 no.1
    • /
    • pp.35-50
    • /
    • 2001
  • The purposes of this study were to investigate the therapeutic effects of an early exercise program after mastectomy and to provide the early exercise program protocol for patients who had undergone mastectomy. The subjects were seventy women who were diagnosed with breast cancer. They were randomly as signed either to a experimental group (n=35) that received early postoperative exercise program or to a control group (n=35) that received only education by nurses. Data were obtained for each patient from goniometric measurements of shoulder flexion, abduction, external rotation, 10 elements of functional performance, and subjective pain evaluation using visual analogue scale (VAS). All variables were measured preoperatively, three days postoperatively, and one month postoperatively. Data were compared by groups using independent t-test and Mann-Whitney U test for parametric or non-parametric data, respectively. There were no significant differences between the groups for all variables preoperatively and at three days postoperatively. But there were significant differences at one month postoperatively. The experimental group showed a statistically significant increases in shoulder flexion, abduction, and external rotation and in the pain VAS at one month postoperatively (p<.05). Also, at one month postoperatively, the experimental group had less difficulty with three elements of functional performance-doing up a 'back' zippered article of clothing, reaching the ipsilateral scapula, and contralateral scapula with the fingers on the operated side-than the control group (p<.05). The results of this study suggest that, after mastectomy, the early exercise program conducted by a well-trained physical therapist can make a significant contribution to the return of more normal shoulder function and activities of daily living and to an increased quality of life.

  • PDF

Automatic Identification of the Lumen Border in Intravascular Ultrasound Images (혈관 내 초음파 영상에서 내강 경계면 자동 분할)

  • Park, Jun-Oh;Ko, Byoung-Chul;Park, Hee-Jun;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.19B no.3
    • /
    • pp.201-208
    • /
    • 2012
  • Accurately segmenting lumen border in intravascular ultrasound images (IVUS) is very important to study vascular wall architecture for diagnosis of the cardiovascular diseases. After each of IVUS image is transformed to a polar coordinated image, initial points are detected using wavelet transform. Then, lumen border is initialized as the set of important points using non parametric probability density function and smoothing function by removing outlier initial points occurred by noises and artifacts. Finally, polynomial curve fitting is applied to obtain real lumen border using filtered important points. The evaluation of proposed method was performed with related method and the proposed method produced accurate lumen contour detection when compared to another method in most types of IVUS images.

Evaluation on Applicability of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steel Considering Local Buckling (국부좌굴을 고려한 건축구조용 고성능강(HSA800) 조립각형강관 압축재의 적용성 평가)

  • Yoo, Jung Han;Kim, Joo Woo;Yang, Jae Guen;Kang, Joo Won;Lee, Dong Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.223-231
    • /
    • 2013
  • Recently, high-performance steels have been increasingly used for structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper offers a series of basic study for the design specification of structural members using high performance steel, that is material properties of HSA800 (High-performance rolled steel for building structures). Built-up square tube stub columns with variables of width-to-thickness ratios are planned as a parametric study in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio. In addition, the buckling behaviors of stub columns obtained finite element (FE) analysis were compared with those from experimental tests. The verified FE model was used for parametric study and checked applicability of high-strength steel on current design specification.

A Study on Evaluation Index of the Panelizing Optimization for Architectural Freeform Surfaces (비정형 파라메트릭 건축부재형성 및 BIM 데이터 변환 프로세스 모델에 관한 연구)

  • Ryu, Jeong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.287-294
    • /
    • 2017
  • BIM technology has been used in the domestic AEC field since the middle 2000s. BIM has proved its worth in cutting-edge buildings, mega-buildings and freeform buildings in particular. Many freeform buildings could not be completed due to the low level of construction technique. However, many successful cases emerged after adopting digital technology, including BIM which encouraged architects to challenge freeform designs. The modeling software that can generate the freeform shape are not usually able to build the efficient BIM data type in the AEC industry. In this study a process model of the parametric freeform construction member generation and conversion to BIM data is shown and the prototype system is demonstrated.

Evaluation of SPECT Analysis in Patients with Transient Global Amnesia

  • Choe, Bo-Young;Kim, Euy-Neyng;Chung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.1
    • /
    • pp.45-53
    • /
    • 2002
  • Objectives: This study investigated alterations in regional cerebral blood flow (rCBF) in patients with transient global amnesia (TGA) using statistical parametric mapping 99 (SPM99). Methods: Noninvasive rCBF measurements using 99mTc-ethyl cysteinate dimer (ECD) SPECT were performed on 8 patients with TGA who have ongoing symptoms and 17 age matched controls. The relative rCBF maps in patients with TGA and controls were compared. Results: In patients with TGA, significant decreased rCBF was found along the L superior temporal extending to L parietal region of the brain and L thalamus. There were areas of increased rCBF in the R temporal, R frontal region and R thalamus. Conclusion: We could demonstrate decreased perfusion in left cerebral hemisphere and increased perfusion in right cerebral hemisphere in patients with TGA using SPM99. The imbalanced change of rCBF between bilateral cerebral hemisphere in patients with TGA might suggest that imbalanced neuronal activity between the bilateral hemispheres may have strong relationship to the pathogenesis of the TGA. For quantitative SPECT analysis in TGA patients, we recommend SPM99 rather than the ROI method because of its definitive advantages.

  • PDF

Prediction Technique of Vibration Induced Settlement -On the Basis of Case Studies (지반 진동에 의한 주변침하 예측기법 사례 연구를 중심으로)

  • 김동수;이진선
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.103-116
    • /
    • 1996
  • Man-made vibrations from traffic and construction activities are important because they may cause damage to structures. The current literature provides that damages in the urban areas were not caused by direct transmission of vibration, but rather through subsequent settlement caused by soil densification. In this paper. prediction technique of ground borne vibration induced settlement was introduced on the basis of case studies. In situ application technique of the settlement prediction model developed in laboratary was described, and the predicted settlement was compared with the measured settlement from case studies. The settlement from case studies hlatched well with the settlement calculated from the model. The parametric studies of settlement in typical urban site conditions were performed to determine the sensitive parameters and to develop reliable vibration monitoring and interpretation schemes. These demonstrated the potential usefulness of the model for the evaluation and prediction of the vibration induced in-situ settlement of sands.

  • PDF

Reduced Regional Cerebral Blood Flow in Patients with Traumatic Brain Injury Who Had No Structural Abnormalities on Magnetic Resonance Imaging : A Quantitative Evaluation of Tc-99m-ECD SPECT Findings (정상 MRI 소견을 보이는 외상성 뇌손상 환자에서 국소뇌혈류량의 이상)

  • Kim, Nam-Hee;Chung, Young-Ki
    • Korean Journal of Biological Psychiatry
    • /
    • v.9 no.2
    • /
    • pp.152-158
    • /
    • 2002
  • Background & Purpose:Neuropsychological disorders after traumatic brain injury(TBI) are poorly correlated with structural lesions detected by structural neuroimaging techniques such as computed tomography(CT) scan or magnetic resonance imaging(MRI). It is well known that patients with TBI have cognitive and behavioral disorders even in the absence of structural lesions of the brain. This study investigated whether there are abnormalities of regional cerebral blood flow(rCBF) in TBI patients without structural abnormality on MRI, using technetium 99m ethyl cysteinate dimer(Tc-99m-ECD) single photon emission computed tomography(SPECT) scans. Materials and Methods:Twenty-eight TBI patients without structural abnormality on MRI(mild, n=13/moderate, n=9/severe, n=6) and fifteen normal controls were scanned by SPECT. A voxel-based analysis using statistical parametric mapping(SPM) was performed to compare the patients with the normal controls. Results:rCBF was reduced in the right uncus and the right lateral orbitofrontal gyrus in the TBI patients. However, no increase of rCBF was noted in the patients in comparison to the normal controls. Conclusions:These results suggest that the TBI patients, even in the absence of structural lesion of the brain, may have dysfunction of the brain, particularly of the orbitofrontal and anterior pole of the temporal cortex. They also suggest that SPECT can be a useful method to identify brain dysfunctions in combination with structural brain imaging and neuropsychological tests.

  • PDF

Comparative Analysis of Factors in Country Risk between Cambodia and Vietnam (캄보디아와 베트남의 국가위험도 영향요인 비교 분석)

  • Lee, Changkeun;Choo, Yongsik
    • Journal of the Korean Regional Science Association
    • /
    • v.34 no.2
    • /
    • pp.65-77
    • /
    • 2018
  • The purpose of this study is to compare and analyze factors in country risk between Cambodia and Vietnam. OECD and the Export-Import Ban of Korea assess country risk of Cambodia more highly than Vietnam. As results of the parametric tests for evaluation factors on the basis of country risk classification, the economic growth rate, the foreign trade index, and the foreign exchange reserves among the economic risks with the corruption index as the political and social risk have statistically significant effect on the difference between country risks of two countries. However, discriminant factor analysis indicates that the economic growth rate, the foreign exchange reserves, and the corruption index are key variables, which represent the difference between country risks of Cambodia and Vietnam. Consequently, the government of Cambodia needs to try to root out the corruption and to expand trade through increasing export for lowering the country risk to the level of Vietnam. Vietnam would also need to focus on attaining the sustainable high economic growth rate and increasing the foreign exchange reserves.

Evaluation on Flexural Performance of Precast Decks with Ribbed Joint by FEM (유한요소해석에 의한 요철형 이음단면을 갖는 프리캐스트 바닥판의 휨성능 평가)

  • Oh, Hyun-Chul;Chung, Chul-Hun;Kang, Myoung-Gu;Park, Se-Jin;Shin, Dong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.85-94
    • /
    • 2016
  • In this study, a non-linear FEM model is presented to predict the static flexural performance of precast bridge decks with ribbed joint and is verified with previous experiment results through comparison. The several theory of material properties were applied to each mechanical properties in FEM model and FEM model's input variables were determined through experiment result and parametric study. The FEM results showed good accuracy in predicting the structural performance of the specimens and FEM model's average error rate was 5%. Also, each specimen's cracking aspect and failure mode can be predicted through FEM's plastic strain distribution. Thus, this FEM model can be used effectively for predicting the ultimate behavior and parametric study to development of design formula for joint.

Revaluation of Nominal Flexural Strength of Composite Girders in Positive Bending Region (정모멘트부 강합성거더의 공칭휨강도 재평가)

  • Youn, Seok Goo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.165-178
    • /
    • 2013
  • This paper presents a research work for the evaluation of the nominal flexural strength of composite girders in positive bending region. Current predicting equations for the nominal flexural strength of composite girders in the 2012 version of the Korea Bridge Design Codes based on Limit State Design Method are able to apply for the composite girders with conventional structural steels. For applying composite girders with high yield strength steels of HSB800 as well as HSB600, there is a need for improving the current predicting equations. In order to investigate the nominal flexural strength of composite girders, previous research works are carefully reviewed and parametric study using a moment-curvature analysis program is conducted to evaluate the ultimate moment capacity and the ductility of a wide range of composite girders. Based on the results of the parametric study, less conservative nominal flexural strength design equations are proposed for conventional composite girders. In addition, new design equations for predicting the nominal flexural strength of composite girders with HSB600 and HSB800 high-performance steels are provided.