• 제목/요약/키워드: Parameter Calibration

검색결과 410건 처리시간 0.028초

원형 지그를 이용한 레이저-비젼 센서의 가상 공간 교정에 관한 연구 (Virtual Space Calibration for Laser Vision Sensor Using Circular Jig)

  • 김진대;조영식;이재원
    • 한국정밀공학회지
    • /
    • 제20권12호
    • /
    • pp.73-79
    • /
    • 2003
  • Recently, the tole-robot operations to an unstructured environment have been widely researched. The human's interaction with the tole-robot system can be used to improve robot operation and performance for an unknown environment. The exact modeling based on real environment is fundamental and important process for this interaction. In this paper, we propose an extrinsic parameter calibration and data augmentation method that only uses a circular jig in the hand-eye laser virtual environment. Compared to other methods, easier estimation and overlay can be done by this algorithm. Experimental results using synthetic graphic demonstrate the usefulness of the proposed algorithm.

Assessment of three optimization techniques for calibration of watershed model

  • Birhanu, Dereje;Kim, Hyeonjun;Jang, Cheolhee;Park, Sanghyun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.428-428
    • /
    • 2017
  • In this study, three optimization techniques efficiency is assessed for calibration of the GR4J model for streamflow simulation in Selmacheon, Boryeong Dam and Kyeongancheon watersheds located in South Korea. The Penman-Monteith equation is applied to estimate the potential evapotranspiration, model calibration, and validation is carried out using the readily available daily hydro-meteorological data. The Shuffled Complex Evolution-University of Arizona(SCE-UA), Uniform Adaptive Monte Carlo (UAMC), and Coupled Latin Hypercube and Rosenbrock (CLHR) optimization techniques has been used to evaluate the robustness, performance and optimized parameters of the three catchments. The result of the three algorithms performances and optimized parameters are within the recommended ranges in the tested watersheds. The SCE-UA and CLHR outputs are found to be similar both in efficiency and model parameters. However, the UAMC algorithms performances differently in the three tested watersheds.

  • PDF

The effect of micro parameters of PFC software on the model calibration

  • Ajamzadeh, M.R.;Sarfarazi, Vahab;Haeri, Hadi;Dehghani, H.
    • Smart Structures and Systems
    • /
    • 제22권6호
    • /
    • pp.643-662
    • /
    • 2018
  • One of the methods for investigation of mechanical behavior of materials is numerical simulation. For simulation, its need to model behavior is close to real condition. PFC is one of the rock mechanics software that needs calibration for models simulation. The calibration was performed based on simulation of unconfined compression test and Brazilian test. Indeed the micro parameter of models change so that the UCS and Brazilian test results in numerical simulation be close to experimental one. In this paper, the effect of four micro parameters has been investigated on the uniaxial compression test and Brazilian test. These micro parameters are friction angle, Accumulation factor, expansion coefficient and disc distance. The results show that these micro parameters affect the failure pattern in UCS and Brazilian test. Also compressive strength and tensile strength are controlled by failure pattern.

개념적 수문분할모형의 보정에 미치는 수문기후학적 조건의 영향 (Effects of Hydro-Climate Conditions on Calibrating Conceptual Hydrologic Partitioning Model)

  • 최정현;서지유;원정은;이옥정;김상단
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.568-580
    • /
    • 2020
  • Calibrating a conceptual hydrologic model necessitates selection of a calibration period that produces the most reliable prediction. This often must be chosen randomly, however, since there is no objective guidance. Observation plays the most important role in the calibration or uncertainty evaluation of hydrologic models, in which the key factors are the length of the data and the hydro-climate conditions in which they were collected. In this study, we investigated the effect of the calibration period selected on the predictive performance and uncertainty of a model. After classifying the inflows of the Hapcheon Dam from 1991 to 2019 into four hydro-climate conditions (dry, wet, normal, and mixed), a conceptual hydrologic partitioning model was calibrated using data from the same hydro-climate condition. Then, predictive performance and post-parameter statistics were analyzed during the verification period under various hydro-climate conditions. The results of the study were as follows: 1) Hydro-climate conditions during the calibration period have a significant effect on model performance and uncertainty, 2) calibration of a hydrologic model using data in dry hydro-climate conditions is most advantageous in securing model performance for arbitrary hydro-climate conditions, and 3) the dry calibration can lead to more reliable model results.

QUAL2Kw 모형을 이용한 자동보정 방법 비교분석과 섬강의 수질관리 대안 평가 (Comparative analysis of auto-calibration methods using QUAL2Kw and assessment on the water quality management alternatives for Sum River)

  • 조재현
    • 환경영향평가
    • /
    • 제25권5호
    • /
    • pp.345-356
    • /
    • 2016
  • 본 연구에서는 GA와 QUAL2K를 통합한 QUAL2Kw 모형을 이용해서 수질모형 매개변수의 자동 보정 방법을 비교 분석하였다. 발전 속도가 빠른 원주시의 배출 오염부하의 영향을 크게 받는 섬강에 QUAL2Kw 모형을 적용하였고, 전 구간 단일 매개변수를 적용하는 방법과 구간별 매개변수를 적용하는 두가지 방법으로 자동보정 방법을 비교 분석하였다. CV(RMSE)의 오차와 GA의 적합도 분석결과 구간별 매개변수 방법이 단일 매개변수 방법보다 정밀도가 다소 높은 것으로 나타났으므로 본 연구에서는 구간별 매개변수 방법으로 계산한 자동보정 결과를 채택하였다. 검보정된 QUAL2Kw 모형을 섬강 수질관리를 위한 세가지 시나리오에 대해 적용해서 수질 개선 효과를 분석하였다. 원주하수처리장 방류수질을 개선하는 시나리오 1에서는 중권역 대표지점인 섬강 4-1지점의 BOD와 TP 농도가 각각 17.7%, 29.1% 감소되었고, 원주천 유입직후 섬강에서는 BOD와 TP 농도가 각각 50.4%, 40.5% 감소하여 섬강 수질 개선효과가 크다. 원주취수장을 폐쇄하고 섬강 이외의 수계에서 원주 일대에 광역상수도를 공급하는 시나리오 2에서는 섬강 중하류부의 유량이 증가함에 따라 섬강 본류의 수질이 소폭 개선된다. 원주천 합류 직후 섬강에서 BOD가 0.18mg/L, TP가 0.0063mg/L 감소하였다. 시나리오 3에서는 시나리오 1과 시나리오 2의 대안을 동시에 계획하는 것으로서 시나리오 1보다 섬강 수질이 소폭 더 개선된다. 시나리오별 수질 예측결과 원주하수처리장의 방류수질을 개선하는 것이 섬강 수질개선에 가장 효과적인 것으로 나타났다. 특히 원주천 합류직후 섬강 수질이 크게 개선된다. 원주취수장을 폐쇄하고 타 수계에서 광역상수도를 통해 원주 지역에 상수도를 공급하는 방안도 섬강 수질을 소폭 개선할 수 있다.

Default Bayesian testing for the scale parameters in two parameter exponential distributions

  • Kang, Sang Gil;Kim, Dal Ho;Lee, Woo Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제24권4호
    • /
    • pp.949-957
    • /
    • 2013
  • In this paper, we consider the problem of testing the equality of the scale parameters in two parameter exponential distributions. We propose Bayesian testing procedures for the equality of the scale parameters under the noninformative priors. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. Thus, we propose the default Bayesian testing procedures based on the fractional Bayes factor and the intrinsic Bayes factors under the reference priors. Simulation study and an example are provided.

Calibration of the depth measurement system with a laser pointer, a camera and a plain mirror

  • Kim, Hyong-Suk;Lin, Chun-Shin;Gim, Seong-Chan;Chae, Hee-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1994-1998
    • /
    • 2005
  • Characteristic analysis of the depth measurement system with a laser, a camera and a rotating mirror has been done and the parameter calibration technique for it has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. The calibration techniques to minimize the effect of such major parameters are proposed.

  • PDF

100GHz 이상의 밀리미터파 HEMT 소 제작 및 개발을 위한 GaAs기반 0.1$\mu\textrm{m}$ $\Gamma$-게이트MHEMT의 DC/RF 특성에 대한 calibration 연구 (A Study on the Calibration of GaAs-based 0.1-$\mu\textrm{m}$ $\Gamma$-gate MHEMT DC/RF Characteristics for the Development and Fabrication of over-100-GHz Millimeter-wave HEMT devices)

  • 손명식;이복형;이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.751-754
    • /
    • 2003
  • Metamorphic HEMTs (MHEMTs) have emerged as excellent challenges for the design and fabrication of high-speed HEMTs for millimeter-wave applications. Some of improvements result from improved mobility and larger conduction band discontinuity in the channel, leading to more efficient modulation doping, better confinement, and better device performance compared with pseudomorphic HEMTs. We have studied the calibration on the DC and RF characteristics of the MHEMT device using I $n_{0.53}$G $a_{0.47}$As/I $n_{0.52}$A1$_{0.48}$As modulation-doped heterostructure on the GaAs wafer. For the optimized device performance simulation, we calibrated the device performance of 0.1-${\mu}{\textrm}{m}$ $\Gamma$-gate MHEMT fabricated in our research center using the 2D ISE-DESSIS device simulator. With this calibrated parameter set, we have obtained very good reproducibility. The device simulation on the DC and RF characteristics exhibits good reproducibility for our 0.1-${\mu}{\textrm}{m}$ -gate MHEMT device compared with the measurements. We expect that our calibration result can help design over-100-GHz MHEMT devices for better device performance.ormance.

  • PDF

Temperature Calibration of a Specimen-heating Holder for Transmission Electron Microscopy

  • Kim, Tae-Hoon;Bae, Jee-Hwan;Lee, Jae-Wook;Shin, Keesam;Lee, Joon-Hwan;Kim, Mi-Yang;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • 제45권2호
    • /
    • pp.95-100
    • /
    • 2015
  • The in-situ heating transmission electron microscopy experiment allows us to observe the time- and temperature-dependent dynamic processes in nanoscale materials by examining the same specimen. The temperature, which is a major experimental parameter, must be measured accurately during in-situ heating experiments. Therefore, calibrating the thermocouple readout of the heating holder prior to the experiment is essential. The calibration can be performed using reference materials whose phase-transformation (melting, oxidation, reduction, etc.) temperatures are well-established. In this study, the calibration experiment was performed with four reference materials, i.e., pure Sn, Al-95 wt%Zn eutectic alloy, NiO/carbon nanotube composite, and pure Al, and the calibration curve and formula were obtained. The thermocouple readout of the holder used in this study provided a reliable temperature value with a relative error of <4%.

다중목적 최적화기 법을 이용한 SWAT 모형 수분매개변수의 자동보정 (Auto-calibration for the SWAT Model Hydrological Parameters Using Multi-objective Optimization Method)

  • 김학관;강문성;박승우;최지용;양희정
    • 한국농공학회논문집
    • /
    • 제51권1호
    • /
    • pp.1-9
    • /
    • 2009
  • The objective of this paper was to evaluate the auto-calibration with multi-objective optimization method to calibrate the parameters of the Soil and Water Assessment Tool (SWAT) model. The model was calibrated and validated by using nine years (1996-2004) of measured data for the 384-ha Baran reservoir subwatershed located in central Korea. Multi-objective optimization was performed for sixteen parameters related to runoff. The parameters were modified by the replacement or addition of an absolute change. The root mean square error (RMSE), relative mean absolute error (RMAE), Nash-Sutcliffe efficiency index (EI), determination coefficient ($R^2$) were used to evaluate the results of calibration and validation. The statistics of RMSE, RMAE, EI, and $R^2$ were 4.66 mm/day, 0.53 mm/day 0.86, and 0.89 for the calibration period and 3.98 mm/day, 0.51 mm/day, 0.83, and 0.84 for the validation period respectively. The statistical parameters indicated that the model provided a reasonable estimation of the runoff at the study watershed. This result was illustrated with a multi-objective optimization for the flow at an observation site within the Baran reservoir watershed.