• Title/Summary/Keyword: Parallel flow type heat exchanger

Search Result 22, Processing Time 0.03 seconds

Analysis of Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Refrigerator using the Hardy-Cross Method (Hardy-Cross법을 이용한 $CO_2$ 냉동기용 내부열교환기의 열전달 특성 연구)

  • Kang Hee-Dong;Kim Ook Joong;Seo Tae-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The heat transfer characteristics of an internal heat exchanger for $CO_2$ refrigeration cycle are numerically investigated. The numerical model is verified using the published experimental results for the concentric tube type internal heat exchanger. The Hardy-Cross Method gives very good agreement between the calculation and experimental results on the heat transfer rates and exit temperatures. Also, appropriate combination of heat transfer correlations is found. The operating parameters of the heat exchanger are calculated at transcritical region of $CO_2.$ The heat transfer rate of the counter flow type heat exchanger shows the $32\%$ greater than that of the parallel flow type heat exchanger. The increase of heat exchanger length enhances the heat transfer rate. The thermodynamic characteristics and heat transfer coefficient of $CO_2$ in the internal heat exchanger are estimated.

A Study on the Performance Characteristics of Fin-type Heat Exchanger for the Automobile Air-Conditioners (자동차 공조용 핀형 열교환기의 성능특성에 관한 연구)

  • 홍경한;전상신;이승재;박찬수;권일욱;김재열;김병철;하옥남
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.100-105
    • /
    • 2004
  • Fin-tube type(Fin-type) heat exchanger has been tested in order to replace the heat exchanger of parallel flow type(P.F -type) which is now widly used in automobile air conditioning system The following conclusions are drawn by the comparison of the characteristics of the heat exchangers. Evaporator and condenser capacities and COP(Coefficience of performance) were varied as with the compressor speed, outdoor air temperature and air flow rate changed, which much influenced on the characteristics of the air conditioning system Evaporator and condenser capacities were increased with increasing compressor speed and outdoor air temperature. Evaporator and condenser pressures of Fin-type were decreased by 7% and 5% respectively compared with those of P.F-type. The COP of Fin-type was decreased with increasing outdoor air temperature and compressor speed. The COP of P.F-type was decreased by 14% compared with that of Fin-type.

Performance Analysis of Moving Bed Heat Exchanger of Solid Particles in a Vertical Pipe (고체입자 이동층을 이용한 수직 전열관 열교환기의 성능해석)

  • Park, Sang-Il;Choe, Gyeong-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2916-2923
    • /
    • 1996
  • A numerical analysis of the moving bed heat exchanger of solid particles inside the vertical pipe was performed using finite difference method. Also, the theoretical solutions were obtained for comparison when the wall heat flux or the wall temperature was assumed constant. The comparison showed that their results agreed well each other. The moving bed heat exchanger was classified as countercurrent-flow, parallel-flow, and cross-flow types according to the gas flow direction. For each type, the thermal efficiency of heat exchanger was calculated as a function of non-dimensional parameters such as the characteristic length of heat exchanger, Biot number and the ratio of thermal capacities of gas and solid particles.

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

The Heat Transfer Performance with Pumping Power for a Particle Bed Heat Exchanger (입자층(粒子層)을 이용한 열교환기(熱交換器)에서 소요동력(所要動力)에 따른 전열특성(傳熱特性)에 관(關)한 연구(硏究))

  • Yoo, J.O.;Yang, H.J.;Cho, Y.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.351-359
    • /
    • 1992
  • In order to improve the performance of heat exchanger, fluidized bed is often employed. The experiments are carried out in fluidized double pipe parallel flow heat exchanger in which finned tube is vertically immersed. And the heat transfer coefficients between the heated tube and fluidized bed of alumina beads(dp=0.41, 0.54, 0.65, 0.77mm) are calculated as a function of air fluidized velocity and pumping power. The effects of particle size, static bed height and pumping power on the heat transfer coefficients are investigated. And the heat transfer coefficients are compared with that of single phase forced convection heat exchanger. In particular, the heat transfer performance of each type heat exchanger is evaluated in relation to the pumping power.

  • PDF

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods (대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

Thermal-hydraulic Design of A Printed-Circuit Steam Generator for Integral Reactor (일체형원자로 인쇄기판형 증기발생기 열수력학적 설계)

  • Kang, Han-Ok;Han, Hun Sik;Kim, Young-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.77-83
    • /
    • 2014
  • The vessel of integral reactor contains its major primary components such as the fuel and core, pumps, steam generators, and a pressurizer, so its size is proportional to the required space for the installation of each component. The steam generators take up the largest volume of internal space of reactor vessel and their volumes is substantial for the overall size of reactor vessel. Reduction of installation space for steam generators can lead to much smaller reactor vessel with resultant decrease of overall cost for the components and related facilities. A printed circuit heat exchanger is one of the compact types of heat exchangers available as an alternative to conventional shell and tube heat exchangers. Its name is derived from the procedure used to manufacture the flat metal plates that form the core of the heat exchanger, which is done by chemical milling. These plates are then stacked and diffusion bonded, converting the plates into a solid metal block containing precisely engineered fluid flow passages. The overall heat transfer area and pressure drops are evaluated for the steam generator based on the concept of the printed circuit heat exchanger in this study. As the printed circuit heat exchanger is known to have much larger heat transfer area density per unit volume, we can expect significantly reduced steam generator compared to former shell and tube type of steam generator. For the introduction of new steam generator, two design requirements are considered: flow area ratio between primary and secondary flow paths, and secondary side parallel channel flow oscillation. The results show that the overall volume of the steam generator can be significantly reduced with printed circuit type of steam generator.

Experimental of Study on Heat Transfer and Pressure drop of PF Heat Exchangers (PF 열교환기의 열전달과 압력강하 특성 실험 연구)

  • Um, Y.S.;Seo, D.N.;Park, K.M.;Lee, S.J.;Kim, D.H.;Kwon, Y.C.
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.519-524
    • /
    • 2008
  • In the present study, the air-side heat transfer and pressure drop characteristics of the fin-tube and PF heat exchangers have been experimentally investigated under the cooling standard condition. Fin type of PF heat exchanger is a triangler and squarer form. The experimental data of the slit fin-tube and two kinds of PF heat exchangers are measured using the air-enthalpy calorimeter and the constant temperature water bath. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. The heat transfer rate and pressure drop of PF-2 heat exchanger of the squarer fin is larger than that of PF-1 heat exchanger of the triangler fin. As the inlet air temperature increases, the heat transfer rate decreases and the pressure drop is nearly uniform.

  • PDF

Flow-Induced Noise and Vibration Due to von Karman Streets in Tube-Bank Ducts of Gas Air Heat Exchangers (열공급 보일러 배가스 열교환기 덕트에서 발생하는 과도 소음 현상)

  • Kim, Yeon-Whan;Koo, Jae-Raeyang;Bae, Yong-Chae;Lee, Hyun;Kim, Sung-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.339-345
    • /
    • 2002
  • When a flow passes a series of parallel ones, vortexes will be formed in the wake after the cylinder. This paper treats the problems of vibration and noise in tube bank of gas flow duct of heat exchanger thermal suppling boiler in combine cycle thermal power plants. The boiler burner type has recently been changed to low Nox burner and begun commercial operation. After more load up operation then 70%, high level noise and vibration were generated at gas flow duct of heat exchanger.

  • PDF