References
- N. C. Baek, 2001, "Development of Off-Peak Electric Water Heater using Heat Pump", Energy R&D, Vol. 11, pp. 3-7.
- J. Y. Lee, J. T. Chung, J. S. Woo, and J, M. Choi, 2010, "Influence of the Secondary Fluid Flow Rate on the Performance of a GSHP System", Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 22, No. 10, pp. 649-656.
- Z. Lian, S. Park, H, Qi, 2005, "Analysis on Energy Consumption of Water-Loop Heat Pump System in China", Applied Thermal Engineering, Vol. 25, pp. 73-85. https://doi.org/10.1016/j.applthermaleng.2004.06.002
- J. M. Choi, S. H. Kang, J. M. Moon, and R. H. Kim, 2009, "Daily Heating Performance of a Ground Source Multi-heat Pump at Heating Mode", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 21, No. 9, pp. 527-535.
- C. Chen, F. Sun, L. Feng, M.. Liu, 2005, "Underground Water-Source Loop Heat-Pump Air-Conditioning System Applied in a Residential Building in Beijing", Applied Energy, Vol. 82, pp. 331-344. https://doi.org/10.1016/j.apenergy.2004.12.002
- A. Hepbasli, 2002, "Performance Evaluation of a Vertical Ground-source Heat Pump System in Izmir", Turky, Int. Journal of Energy Res., Vol. 26, pp. 1121-1139. https://doi.org/10.1002/er.839
- A. Hepbasli, O. Akdemir, E. Hancioglu, 2003, "Experimental Study of a Closed Loop Vertical Ground Source Heat Pump System", Energy Conversion and Management, Vol. 44, pp. 527-548. https://doi.org/10.1016/S0196-8904(02)00073-0
- B. H. Sohn, C. S. Cho, H. J. Shin, and H. J. An, 2005, "Cooling and Heating Performance Evaluation of a GSHP System", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 1, pp. 71-81.
- D. A. Cha, O. K. Kwon, and C. S. Park, 2012, "A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods", Transactions of the Korea Society of Geothermal Energy Engineers, Vol. 8, No. 2, pp. 9-15.
- D. A. Cha, O. K. Kwon, and C. S. Park, 2012, "A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods", Korea Journal of Air-Conditioning and Refrigeration Engineering, Vol. 24, No. 8, pp. 605-611. https://doi.org/10.6110/KJACR.2012.24.8.605
- D. H. Han, K. J. Lee, 2003, "Experiments on the Characteristics of Evaporation of R410A in Brazed Plate Heat Exchangers with Different Geometric Configurations", Applied Thermal Engineering, Vol. 23, pp. 1209-1225 https://doi.org/10.1016/S1359-4311(03)00061-9
- Y. S. Kim, 1999, "An Experimental study on Evaporation Heat Transfer Characteristics and Pressure Drop in the Plate heat Exchanger", MS thesis, Yonsei University, Seoul, Korea
- M. K. Seo, J. H. Park and Y. S. Kim, 2001, "A Study on the Performance Analysis in the Plate and Shell Heat Exchanger", Journal of The Korean Society for Power System Engineering, Vol. 5, No. 1, pp. 35-43.
- ARI Standard 480-2001, "Remote Type Refrigerant-Cooled Liquid Coolers"