• 제목/요약/키워드: Parallel flow type$H_2O$

검색결과 8건 처리시간 0.019초

하수처리수이용 흡수식냉동사이클의 해석 (Analysis of Absorption Refrigeration Cycles to Utilize Treated Sewage)

  • 이용화
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.288-298
    • /
    • 1996
  • The gas-fired absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cycles with parallel or series flow type has been performed. The working fluid is Lithium Bromide and water solution. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The efficiency of a couple of cycles has been studied and simulation results show that higher coefficient of performance could be obtained for parallel flow type. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficent of performance in the paralledl flow type.

  • PDF

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

공랭형 병렬방식 2중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System with Parallel Flow Type)

  • 오명도;김선창;김영인;이홍원
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2099-2109
    • /
    • 1993
  • A gas-fired 4RT absorption heat pump was designed as an air-conditioner for domestic use during the summer. The absorption heat pump is air-cooled. double-effect, $LiBr-H_{2}O$ system with parallel flow type. The performance of the absorption heat pump in the cooling mode of operation was investigated through cycle modeling and simulation to obtain the system characteristics with parameter changes. System parameters considered in this analysis were the inlet temperature of cooling air to the absorber, the working solution concentrations, the ratio of the amount of the weak solution from the absorber, and the LTD's of each heat exchange component. The optimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance.

H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH)

  • 권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

Simulation of $H_2O/LiBr$ Triple Effect Absorption Systems with a Modified Reverse Flow

  • Jo, Young-Kyong;Kim, Jin-Kyeong;Kang, Yang-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.114-121
    • /
    • 2007
  • In this study, a modified reverse flow type, one of the triple effect absorption cycles, is studied for performance improvement. The cycle simulation is carried out by using EES(Engineering Equation Solver) program for the working fluid of $H_2O/LiBr$ solution. The split-ratios of solution flow rate, UA of each component, pumping mass flow rate of solution are considered as key parameters. The results show that the optimal SRH (split ratio of high side) and SRL (split ratio of low side) values are 0.596 and 0.521, respectively. Under these conditions, the COP is maximized to 2.1. The optimal pumping mass flow rate is selected as 3 kg/s and the corresponding UAEV A is 121 kW/K in the present system. The present simulation results are compared to the other literature results from Kaita's (2002) and Cho's (1998) triple effect absorption systems. The present system has a lower solution temperature and a higher COP than the Kaita's modified reverse flow, and it also gives a higher COP than the Cho's parallel flow by adjusting split ratios.

하수열을 이용한 냉난방시스템에 관한 연구 (Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle)

  • 이용화;신현준;윤희철;박현건
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.

공냉식 흡수식 냉동기의 특성 해석 (Characteristic analysis of air-cooled absorption refrigeration machine)

  • 권오경;문춘근;양영명;유선일;윤정인
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 1998년도 추계학술발표회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the study of developing air-cooled absorption system which uses a new working solution instead of LiBr solution to improve the performance of system. The absorption chiller-heater considered was an air-cooled, double-effect, $H_2O/LiBr+HO(CH_2)_3$ system of parallel flow type. In this study, we found out the characteristic of new working solution through the cycle simulation and compared the result that of LiBr solution to evaluate. The new working fluid has a wider working range with $8\%$ higher crystallization limit at the saturated refrigerant pressure of 0.8kPa. The optimum designs and operating conditions of air-cooled absorption system were suggested based on this cycle simulation analysis. It was demonstrated that new working fluid substantially improves the performance of the absorption refrigeration machine and is expected to increase the COP by as much as $5\%$.

  • PDF

시간 경과에 따른 YBCO 초전도 복합체의 포획 자기장 감쇄 (The Trapped Field Decay of YBCO Superconductor Composite with Times)

  • 이만수;장건익;전병혁;하동우;손명환;한영희;박병준
    • Progress in Superconductivity
    • /
    • 제12권2호
    • /
    • pp.82-87
    • /
    • 2011
  • We studied the trapped field properties of bulk Y-Ba-Cu-O superconductors by applying 3 T of the permanent or $Nb_3Ti$ superconducting magnet. The 28 mm circular type of YBCO bulk superconductor was prepared and then hole at the center of bulk, parallel to the c-axis, was mechanically drilled. Typical size of hole in YBCO bulk was 10 mm in diameter. In order to examine the trapped field variation in terms of different impregnated materials, a hole in YBCO bulk was filled with resin and indium respectively. The trapped field decay due to flux flow was determined in terms of time. Our preliminary result indicates the trapped field value measured on the YBCO without hole after 30 minute by applying 3 T, was 6,500 G, which is much higher than that, 4,500 G, measured on YBCO with hole. Also, we confirmed that the tendency of a trapped field decrement with time was almost the same regardless of the impregnated materials in YBCO.