• Title/Summary/Keyword: Parallel connecting

Search Result 155, Processing Time 0.021 seconds

Effects of Neck and Pelvic Exercise Using Swiss Ball on Spinal Curve in Adults with Forward Head Posture (전방머리자세 대상자에 대한 목운동과 골반운동이 척추 굽이에 미치는 효과)

  • Bae, Won-Sik;Jang, Chel
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.193-201
    • /
    • 2021
  • Purpose : The purpose of this study was to compare the effect of pelvic exercise on the CVA and spinal curve in adults with forward head posture compared to the group using only neck exercise when pelvic exercise was performed in parallel with conventional neck exercise. Methods : GPS 400 and Formetric were used to identify craniovertebral angle (CVA), thoracic kyphosis, lumbar lordosis, and pelvic torsion and were measured by an experienced research manager. Forward head posture (FHP) was selected for people whose angle between the line connecting the ear ball and the seventh cervical spine and the horizontal line is 50 degrees or less. The 30 selected students were randomly divided into 15 experimental groups and 15 control groups. Mackenzie exercise and sling exercise were performed for neck exercise in both the experimental group and the control group, and pelvic exercise using a Swiss ball was additionally performed in the experimental group. All data collected in this study were analyzed using SPSS statistics 21.0. Cervical vetebral angle (CVA), thoracic kyphosis, lumbar lordosis, and pelvic torsion were compared at 0 weeks, 3 weeks, and 6 weeks for each measurement factor using ANOVA with repeated measures. For the statistical significance test, the significance level of α was set to .05. Results : The changes of pelvic torsion, thoracic kyphosis and CVA due to pelvic exercise using Swiss Ball and neck exercise were changed over time, but lumbar lordosis were not changed. And there were no significant differences among the groups. Conclusion : In conclusion, the pelvic correction exercise is considered to be an effective exercise for correcting the FHP and requires regular pelvic correction exercises. We expect the results to be used in clinical trials.

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

  • Ozcan Akkal;Ismail Hakki Korkmaz;Funda Bayindir
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.179-188
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 ㎛, the values of 104 ㎛ and 171 ㎛ were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.

Development of an Automatic Measuring Program for the Craniovertebral Angle Using Photographic Image (사진 영상을 이용한 머리척추각 자동 측정 프로그램 개발)

  • Soo-Young Ye;Jong-Soon Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: The prevalent use of mobile devices may contribute to musculoskeletal disorders, such as forward head posture (FHP), among users. The measurement of the craniovertebral angle (CVA) using photographic images is frequently employed in assessing FHP. Although manual CVA measurement using photographic images is reliable in clinical settings, computer programs or mobile applications to support tele-physical therapy are not yet fully developed. Therefore, in the current study, we propose an automatic method for extracting CVA from photographic images of FHP subjects to facilitate tele-physical therapy. Methods: To develop the automatic CVA measuring computer program, photographic images were obtained from 10 FHP participants. The location information obtained from the markers attached to the tragus and the spinous process of the seventh cervical vertebra were used as coordinates. Using these coordinates, straight line 1 was generated by connecting the seventh spinous process of the cervical vertebra and the tragus, while straight line 2 was drawn parallel to the coordinate obtained from the seventh spinous process of the cervical vertebra. The arc tangent function was used to calculate the angle between the two straight lines. The automatic CVA measurement computer program utilizing photographic images was developed using MATLAB (ver. 2016b). Results: The results showed that the automatic CVA measurement computer program demonstrated stable repeatability and high accuracy. Conclusion: The proposed approach was able to automatically estimate the CVA using photographic images. The developed computer program can potentially be used for easier and more reliable clinical assessment of FHP.

The Effect of the Discontinuity Spacing/Length Ratio on Step-Path Failure of Jointed Rock Slopes (절리 암반 사면의 계단 경로 파괴에 미치는 불연속면 간격/길이 비의 영향)

  • Woon Sang Yoon
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.317-327
    • /
    • 2024
  • When a non-persistent joint system is formed in a large-scale rock slope, slope failure may occur due to presence of a the stepped sliding surface. Such a surface can be divided into joint-to-joint sliding surfaces or joint-to-rock bridge sliding surfaces. In the latter case, the rock bridge provides shear resistance parallel to the joint and tensile resistance perpendicular to the joint. The load of the sliding rock can lead to failure of the rock bridge, thereby connecting the two joints at each ends of the bridge and resulting in step-path failure of the slope. If each rock bridge on a slope has the same length, the tensile strength is lower than the shear strength, resulting in the rock bridges oriented perpendicular to the joint being more prone to failure. In addition, the smaller the ratio of discontinuity spacing to length, the greater the likelihood of step-path failure. To assess the risk of stepped sliding on a rock slope with non-persistent joints, stability analysis can be performed using limit equilibrium analysis or numerical analysis. This involves constructing a step-path failure surface through a systematic discontinuity survey and analysis.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

The New Conflict of Laws Act of the Republic of Korea (개정 국제사법(國際私法)의 소개 : 국제거래(國際去來)에 미치는 영향을 중심으로)

  • Suk, Kwang-Hyun
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.20
    • /
    • pp.23-62
    • /
    • 2003
  • The Law amending the Conflict of Laws Act of the Republic of Korea ("Korea"), which had taken two years to prepare, was promulgated on April 7, 2001 and finally took effect as of July 1, 2001. Accordingly, the old earlier Conflict of Laws Act which was called "Seoboesabeop" in Korean ("Prior Act"Old Act) was replaced by the new Conflict of Laws Act called "Gukjesabeop" in Korean ("New Act"). In fact the Old Act Prior Act was promulgated in 1962, but it was regarded as outdated from the moment of its promulgation. However, since the Old Act because it was modeled after the chapter of the Private International Law of the Einfuehrungsgesetz zum Buergerlichen Gesetzbuch (EGBGB) of the Federal Republic of Germany ("German PIL") and the Japanese Private International Law ("Japanese PIL") which had been promulgated toward the end of the 19th century., the Old Act was viewed as outdated from the moment of its promulgation. As a result of the drastic change of the environment for international trade of which that has taken took place in parallel with the global information technology revolution on a global basis, the scope of issues to be addressed which should be resolved by the conflict of laws principles has been remarkably expanded, and various new issues of an entirely which are quite new in its type and nature have arisen been raised. In the field of conflict of laws in its narrow sense, a revolution or crisis of the traditional conflict of laws has been brought about by the advent in the United States rise of a the new methodology for of the conflict of laws, of the United States of America and in the process of overcoming the such crisis the conflict of laws of the European continent has undergone substantial changes such as the diversification of the connecting principles, the expansion of the principle of party autonomy and the consideration of the value of the substantive law to protect socio-economically weaker parties of. The Prior Act, which was based on However, with the mechanical connecting principles and contained various outdated the inappropriate provisions, the Old Act could not cope with the issues raised by the internationalization and globalization of the Korean society. Furthermore In addition, the Old Act Prior Act was regarded as insufficient in that it lacked rules on international jurisdiction to adjudicate, or international adjudicatory jurisdiction, whereas the expectation of the public was that the Conflict of Laws a Act should function as the "Basic Law of the International Legal Relationships"encompassing rules on international jurisdiction given the increase of international disputes. Furthermore the private international law has also attracted more attention from the Korean At the beginning of the new Millennium, thanks to the promulgation of the New Act, I believe that Korea has succeeded in achieving the modest goal of reflecting in the its codification substantial parts of the major developments of the private international law which the leading advanced continental European countries had achieved during the last century. The New Act has followed the approach of the traditional conflict of laws of the European continent. It is a product of the efforts to eliminate the then existing problems of the Prior Old Act and to adapt the Korean private international law regime to the standard of international conventions and national laws of advanced countries. Unlike the Prior Old Act which was heavily dependent upon the prior Japanese PIL and the prior German PIL, the New Act has been prepared by taking into full account the Rome Convention, the Swiss PIL, the new German PIL which took effect in 1986 and various conventions adopted by the Hague Conference. Therefore, the New Act has substantially reduced dependence upon the Japanese PIL and the German PIL, and has gained relatively greater universal validity. The fact that the New Act expressly declares that the determination of international jurisdiction is a matter of conflict of laws is a clear sign that it has departed from the German tradition which confines the conflict of laws principles to choice of laws rules, and moved toward a broader and more practical approach widely accepted in the area of conflict of laws. It is hoped, and I am personally confident, that the New Act will be able to achieve its intended objectives in the 21st century as the basic law for the ever-increasing legal relationships with a foreign element.

  • PDF

A research on improving signal to noise ratio for magnetic resonance imaging through increasing filling factor inside surface coil (자기공명 검사시 코일 내 filling factor 증가를 통한 신호대 잡음비의 향상에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5299-5304
    • /
    • 2012
  • MRI signals are significantly reduced by the magnetic field inhomogenity result from human body itself being consisted of various materials like air, fat, muscle, bone and blood vessels. In this study we used silicon which is tissue equivalent to compensate wound body shapes. Objects were eight adults who do not have any special symptoms. Feet were scanned because of their complicated structures and consequently signal reduction occurs a lot. Thirty images were acquired from the middle of arcus pedis longitudinalis including five distal phalanges parallel to the line connecting metatarsal bone and phalanges. SNR data from bones and soft tissues were compared before and after sticking silion between toes and paired t test was performed. It was came out that SNR data from bone and soft tissue were both significantly higher after applying silicon on both T1 and T2 weighted images and it was statistically meaningful having positive corelation. As a result, this study dramatically increases SNR without affecting object by increasing the object volume inside the surface coil.

Bacillus thuringiensis Cry4A and Cry4B Mosquito-larvicidal Proteins: Homology-based 3D Model and Implications for Toxin Activity

  • Angsuthanasombat, Chanan;Uawithya, Panapat;Leetachewa, Somphob;Pornwiroon, Walairat;Ounjai, Puey;Kerdcharoen, Teerakiat;Katzenmeier, Gerd;Panyim, Sakol
    • BMB Reports
    • /
    • v.37 no.3
    • /
    • pp.304-313
    • /
    • 2004
  • Three-dimensional (3D) models for the 65-kDa activated Cry4A and Cry4B $\delta$-endotoxins from Bacillus thuringiensis subsp. israelensis that are specifically toxic to mosquito-larvae were constructed by homology modeling, based on atomic coordinates of the Cry1Aa and Cry3Aa crystal structures. They were structurally similar to the known structures, both derived 3D models displayed a three-domain organization: the N-terminal domain (I) is a seven-helix bundle, while the middle and C-terminal domains are primarily comprise of anti-parallel $\beta$-sheets. Circular dichroism spectroscopy confirmed the secondary structural contents of the two homology-based Cry4 structures. A structural analysis of both Cry4 models revealed the following: (a) Residues Arg-235 and Arg-203 are located in the interhelical 5/6 loop within the domain I of Cry4A and Cry4B, respectively. Both are solvent exposed. This suggests that they are susceptible to tryptic cleavage. (b) The unique disulphide bond, together with a proline-rich region within the long loop connecting ${\alpha}4$ and ${\alpha}5$ of Cry4A, were identified. This implies their functional significance for membrane insertion. (c) Significant structural differences between both models were found within domain II that may reflect their different activity spectra. Structural insights from this molecular modeling study would therefore increase our understanding of the mechanic aspects of these two closely related mosquito-larvicidal proteins.

De-duplication of Parity Disk in SSD-Based RAID System (SSD 기반의 RAID 시스템에서 패리티 디스크의 중복 제거)

  • Yang, Yu-Seok;Lee, Seung-Kyu;Kim, Deok-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.105-113
    • /
    • 2013
  • RAID systems have been widely used by connecting several disks in parallel structure. to resolve the delay and bottleneck of data I/O. Recently, SSD based RAID systems are emerging since SSDs have better I/O performance than HDD. However, endurance and power consumption problems due to frequent write operation in SSD based RAID system should be resolved. In this paper, we propose a de-duplication method of parity disk in SSD based RAID system with expensive update cost. The proposed method segments chunk of parity data into small pieces and removes duplicate data, therefore, it can reduce wear-leveling and power consumption by decreasing write operation for duplicated parity data. Experimental results show that bit update rate of the proposed method is 16% in total disk, 31% in parity disk less than that of existing method in RAID-6 system using EVENODD erasure code, and the power consumption of the proposed method is 30% less than that of existing method. Besides the proposed method is 12% in total disk, 32% in parity disk less than that of existing method in RAID-5 system, and the power consumption of the proposed method is 36% less than that of existing method.

Development of Program for Discretionary Activity Focused on Multiple Activity with Everyday-Life Materials to Enhance Scientific Creativity for Grade 6-7 Students and Exploring the Influence (과학창의력 신장을 위한 ‘일상생활 소재 다중활동’ 중심의 6~7학년 ‘재량활동’)

  • 김형석;정용재;곽성일;하은선;이선양;이현정
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.4
    • /
    • pp.344-356
    • /
    • 2004
  • In this study, we developed the program for 'Discretionary Activity' focusing on the multiple activities with everyday-life materials to enhance scientific creativity (MAEM-SC), which was specifically for students in the 6-7th grade according to the 7th curriculum in Korea. As important factors for scientific creativity, we selected the ability to find out the context relevant to scientific problems, the ability to connect the problem context to scientific knowledge, the ability to invent the ways to solve the problem scientifically, and ability to concentrate on the scientific problem solving activity. The topics of the program were drawn from common and familiar things in our everyday contexts, such as human body, everyday tools, food, play and toys, and everyday episodes. The multiple activities here mean the activities which are systematically constructed with the various types of activities with a specific intention. The multiple activities were designed in three types, that is, series type, parallel type, and combination type. Each of them consists of the several activities as follows: estimating and measuring, carrying out an experiment using body, inventing implement (tools), thinking statistically, writing creatively with scientific themes, and connecting one concept to another concept etc. Through a trial of the program, we found that this program has some positive influence on the enhancement both of the ability to find out the context relevant to scientific problems and the ability to connect it to the students' existing scientific knowledge.

  • PDF