• Title/Summary/Keyword: Parallel Lines

Search Result 399, Processing Time 0.026 seconds

Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines (병행 배전선로에서의 통신선 유도전압 계산)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seong-Heon;Kim, Seong-Arm;Weon, Bong-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

A New fault Location Algorithm for 765㎸ Untransposed Parallel Transmission Lines (765㎸ 비연가 송전선로에서 고장점 표정 알고리즘)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.168-174
    • /
    • 2004
  • This paper describes a new fault location algorithm based on the voltage equation at the relaying point using 6-phase current for untransposed 765㎸ parallel transmission lines. The proposed method uses the voltage and current collected at only the local end. By means of 3-phase circuit analysis theory to compensate the mutual coupling effects between parallel lines, the fault location is derived. The fault distance is determined by solving the 2nd distance equation based on KVL(Kirchhoff's Voltage Law). Extensive simulation results using EMTP(Electromagnatic Transients Program) have verified that the error of the fault location achieved is up to 4.56(%) in untransposed parallel transmission lines.

A study on the relationship between 'parallel' and 'identical' in school mathematics (학교수학에 나타나는 '평행'과 '일치'의 관계)

  • Nam, JinYoung;Cho, Seongmin
    • Communications of Mathematical Education
    • /
    • v.27 no.1
    • /
    • pp.81-97
    • /
    • 2013
  • In this study, we investigated how the relationship between 'parallel' lines and 'identical' lines is stated in mathematics textbooks of the 2007 revised national curriculum. In school mathematics, 'parallel' lines and 'identical' lines are explicitly distinguished in the perspective of 'coincidence', whereas 'identical' lines are implicitly regarded as a special case of 'parallel' in the perspective of 'slope'. These different treatments could bring out a confusion as was in the mock mathematics test for 2012 College Scholastic Ability Test. To resolve this confusion, it needs to be considered that the relationship between 'parallel' lines and 'identical' lines are more clearly stated in the context of 'slope' such as in some textbooks for the 4th and 5th curriculum and a textbook of Japan.

A Note on Dealing with Some Contents of Geometry in the Middle School Mathematics (중학교 수학에서 기하 내용 취급에 관한 연구)

  • 김흥기
    • Journal of Educational Research in Mathematics
    • /
    • v.14 no.1
    • /
    • pp.111-127
    • /
    • 2004
  • In this note we examined some terms, parallel lines and angles in elementary school mathematics and middle school mathematics respectively. Since some terms are represented early in elementary school mathematics and not repeated after, some students are not easy to apply the terms to their lesson. Also, since the relation between parallel lines and angles are treated intuitively in 7-th grade, applying the relation for a proof in 8-th grade would be meaningless. For the variety of mathematics education, it is desirable that the relation between parallel lines and angles are treated as postulate. Also, for out standing students, it is desirable that we use deductive reasoning to prove the relation between parallel lines and angles as a theorem. In particular, the treatments of vertical angles and the relation between parallel lines and angles in 7-th grade text books must be reconsidered. Proof is very important in mathematics, and the deductive reasoning is necessary for proof. It would be efficient if some properties such as congruence of vertical angles and the relation between parallel lines and angles are dealt in 8-th grade for proof.

  • PDF

A Monocular Vision Based Technique for Estimating Direction of 3D Parallel Lines and Its Application to Measurement of Pallets (모노 비전 기반 3차원 평행직선의 방향 추정 기법 및 파렛트 측정 응용)

  • Kim, Minhwan;Byun, Sungmin;Kim, Jin
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.11
    • /
    • pp.1254-1262
    • /
    • 2018
  • Many parallel lines may be shown in our real life and they are useful for analyzing structure of objects or buildings. In this paper, a vision based technique for estimating three-dimensional direction of parallel lines is suggested, which uses a calibrated camera and is applicable to an image being captured from the camera. Correctness of the technique is theoretically described and discussed in this paper. The technique is well applicable to measurement of orientation of a pallet in a warehouse, because a pair of parallel lines is well detected in the front plane of the pallet. Thereby the technique enables a forklift with a well-calibrated camera to engage the pallet automatically. Such a forklift in a warehouse can engage a pallet on a storing rack as well as one on the ground. Usefulness of the suggested technique for other applications is also discussed. We conducted an experiment of measuring a real commercial pallet with various orientation and distance and found for the technique to work correctly and accurately.

Study on the analysis of Crosstalk at Interconnects in Integrated Circuits (집적회로의 다층 금속 배선에서의 혼신 특성 해석에 관한 연구)

  • 김연태;최익준;권오섭;원태영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.29-40
    • /
    • 2004
  • This paper reports the frequency characteristics and the time response of parallel adjacent-transmission lines, crossed adjacent-transmission lines and parallel adjacent-transmission lines which are on the different planes by using FDTD-PML method. In the parallel adjacent-transmission lines, the crosstalks as a function of horizontal distance are calculated and in the crossed adjacent- transmission lines, the crosstalks as a function of vertical distance are simulated. Also, the crosstalks as functions of horizontal and vertical distances are measured and analyzed in the parallel adjacent-transmission lines which are on the different planes.

Analysis of Induced Voltage on Telecommunication Line in Parallel Distribution System

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Lee, Soon-Jeong;Kim, Chul-Hwan;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.726-732
    • /
    • 2014
  • A current flowing through a distribution conductor produces induced voltage, which is harmful to a telecommunication line. Previous research on induced voltage has been focused on single-circuit lines in the distribution system. However, the double-circuit lines, referred to as parallel distribution lines, are widely used in distribution systems because they have significant economic and environmental advantages over single-circuit lines. Therefore, a study on the induced voltage in double-circuit lines is needed. This paper presents a method of calculating the induced voltage in a parallel distribution system using four-terminal parameters and vector analysis. The calculation method is verified by the Electromagnetic Transient Program (EMTP) simulation.

Equivalent Circuit Design of 2.4 GHz Band LTCC Bandpass Filters Using Multilayer Inter-Digital Resonators (적층 Inter-Digital 공진기를 이용한 2.4 GHz 대역 LTCC 대역통과 여파기의 등가회로 설계)

  • Sung Gyu-Je
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.78-83
    • /
    • 2005
  • LTCC filters have been widely used to wireless terminals. They generally adopt the multilayer structure. Some of multilayer LTCC filters are made of symmetrical parallel-coupled lines and anti-symmetrical parallel-coupled lines to reduce the length of resonators. The equivalent circuit of parallel-coupled lines was analyzed and applied to bandpass filters using multilayer parallel-coupled line resonators. The three-pole bandpass filter with the center frequency of 2.45 GHz is designed by using the proposed equivalent circuit and the measured results have good agreement with the design results.

A Study on Compound Technique for Increasing the Bandwidth of Microstrip Antennas using the Paralle Coupled Lines (평행 결합 선로를 이용한 복합 광대역 기법 적용 마이크로스트립 안테나에 관한 연구)

  • 김정일;한만군;윤영중
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.713-721
    • /
    • 2001
  • In this paper, parasitic patches gap-coupled microstrip antenna and stacked microstrip patch antenna combined with parallel coupled lines, which are a kind of wideband impedance matching network, are proposed to get the wider bandwidth. The iterative method using a distributed network is proposed to design the parallel coupled lines as a wideband impedance matching network. Measurements show that the proposed antennas provide wider bandwidths ~1.6 times and ~1.5 times those of conventional parasitic gap-coupled microstrip patch antenna and stacked microstrip patch antenna. In addition, measured radiation patterns show no serious variation of radiation patterns though the parallel coupled lines is added. The antenna gain is, however, lowered about 1 dB and 0.5 dB by the coupling loss in the parallel coupled lines.

  • PDF