• Title/Summary/Keyword: Paper Heat exchanger

Search Result 477, Processing Time 0.024 seconds

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

Applicability Evaluation of Methodology for Evaluating High Cycle Thermal Fatigue of a Mixing Tee in Nuclear Power Plants (원전 혼합배관 고주기 열피로 평가방법론의 적용성 평가)

  • Kim, Sun-Hye;Sung, Hee-Dong;Choi, Jae-Boong;Huh, Nam-Su;Park, Jeong-Soon;Choi, Young-Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.44-50
    • /
    • 2011
  • Turbulent mixing of hot and cold coolants is one of the possible causes of high cycle thermal fatigue in piping systems of nuclear power plants. A typical situation for such mixing appears in turbulent flow through a T-junction. Since the high cycle thermal fatigue caused by thermal striping was not considered in the piping fatigue design in several nuclear power plants, it is very important to evaluate the effect of thermal striping on the integrity of mixing tees. In the present work, before conducting detailed evaluation, three thermal striping evaluation methodology suggested by EPRI, JSME and NESC are analyzed. Then, a by-pass pipe connected to the shutdown cooling system heat exchanger is investigated by using these evaluation methodology. Consequently, the resulting thermal stresses and the fatigue life of the mixing tee are reviewed and compared to each other. Futhermore, the limitation of each methodology are also presented in this paper.

Fabrication of SiCN microstructures for super-high temperature MEMS using PDMS mold and its characteristics (PDMS 몰드를 이용한 초고온 MEMS용 SiCN 미세구조물 제작과 그 특성)

  • Chung, Gwiy-Sang;Woo, Hyung-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.53-57
    • /
    • 2006
  • This paper describes a novel processing technique for fabrication of polymer-derived SiCN (silicone carbonitride) microstructures for super-temperature MEMS applications. PDMS (polydimethylsiloxane) mold is fabricated on SU-8 photoresist using standard UV photolithographic process. Liquid precursor is injected into the PDMS mold. Finally, solid polymer structure is cross-linked using HIP (hot isostatic pressure) at $400^{\circ}C$, 205 bar. Optimum pyrolysis and annealing conditions are determined to form a ceramic microstructure capable of withstanding over $1400^{\circ}C$. The fabricated SiCN ceramic microstructure has excellent characteristics, such as shear strength (15.2 N), insulation resistance ($2.163{\times}10^{14}{\Omega}$) and BDV (min. 1.2 kV) under optimum process condition. These fabricated SiCN ceramic microstructures have greater electric and physical characteristics than bulk Si wafer. The fabricated SiCN microstructures would be applied for supertemperature MEMS applications such as heat exchanger and combustion chamber.

Simulation and Energy Cost Calculation of Encapsulated Ice Storage System (캡슐형 빙축열시스템에 대한 운전 시뮬레이션 및 에너지비용 분석)

  • Lee, K.H.;Joo, Y.J.;Choi, B.Y.;Kim, S.J.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.63-73
    • /
    • 1999
  • Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.

  • PDF

A Study on the Spray Freeze Dryer for Extracting Valuable Material of the Deep Seawater (해양심층수 물질추출용 분무동결건조기에 관한 연구(1))

  • PARK SEONG-JE;HONG YONG-JU;KIM HYO-BONG;KIM HYEON-JU;SHIN PHIL-KWON
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1-6
    • /
    • 2004
  • This paper shows the study on the design and another applications of the spray-freeze dryer for the production of valuable material powders. Powder production and handling has been an integral part of material extracting processing and pharmaceutical processing because of the wide use of oral dosage forms. There are a few commonly used powder preparation methods including mechanical milling, precipitaion, spray drying, freeze drying, and so on. In general, methods available for preparing inhalation powders are limited due to certain inhalation powder's sensitive nature to the processing environments. This is particularly true for preparing dry powder aerosols where the aerodynamic particle size($<5{\mu}m$) and the size distribution are pivotal. Supercritical fluid antisolvent and spray freeze drying have recently emerged as promising techniques for producing powders for use in microcapsulation. However, the aerosol applications of these powders are yet to be explored. The purpose of this study is to test the feasibility of using spray freeze-dried valuable material powders for aerosolization.

  • PDF

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

An Experimental and Field Study on Thermal Performance of Thermosyphon Solar Hot Water System (자연대류형 태양열 온수 급탕 시스템의 열성능 및 실증실험)

  • Kang, Y.H.;Kwak, H.Y.;Jeon, H.S.
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.16-26
    • /
    • 1991
  • This paper studies development of a solar thermosyphon hot water system which is suitable to korean climate and life style, to save energy consumed for domestic water heating. The system consists of two flat plate collectors(or three flat plate collectors) connected in parallel and a storage tank of 300 liter capacity with heat exchanger and the optimum system was designed through the comparative measurements of five different storage tanks. The developed system manufactured with domestic materials were installed in residential buildings in seven cities(Seoul, Pusan, Taegu, Kwangju, Taejeon, Kangneung, Cheju) for demonstration and field test and results show possibility for commercialization.

  • PDF

Design of Retarder Control Logic for Cooling System of Commercial Vehicle (상용차의 냉각 시스템을 고려한 리타더 제어로직 설계)

  • Lee, Chang-Kyu;Jeong, Jong-Kyu;Kim, Gwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.668-669
    • /
    • 2016
  • The retarder as a hydraulic brake system in order to assist a service brakes in commercial vehicle is operated by automatic and manual mode due to driver. Braking energy by retarder operation is transmitted to the engine radiator of vehicle cooling system, passing through the retarder oil heat exchanger. At this moment, the retarder ECU performs the function that is controlled a braking torque with consideration for automatic and manual mode, temperature of retarder oil/water, engine coolant temperature, vehicle speed, and etc. In this paper, it deals with the design of retarder control logic and the results of retarder braking performance test regarding a cooling system of retarder and vehicle.

  • PDF

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.

Fin and Temperature Effect of Frost in Ambient Air Vaporizer

  • Lee, Seong-Woo;Choi, Sung-Woong
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.211-216
    • /
    • 2022
  • Since liquefied natural gas (LNG) is imported in a liquid state of about -162℃ to increase transportation efficiency in Korea, it must be vaporized in a gaseous state to supply it to consumers. Among them, ambient air vaporizer (AAV) has caught attention due to eco-friendly and low costs characteristics. However, there is a disadvantage that the performance of the heat exchanger is deteriorated due to frost due to mist and icing when used for a long time. In this paper, frost generation model in AAV vaporizer was investigated with numerically to examine utilizing the vaporizer performance with the frost generation behavior. The frost generation behavior of AAV vaporizers was examined with humidity, fin characteristic, and temperature effects. As for the LNG discharge temperature, the 12 fin vaporizer showed the highest discharge temperature when the atmospheric temperature was 25℃, and the 8 fin vaporizer had the lowest LNG discharge temperature when the atmospheric temperature was 0℃. In the case of frost formation, in the case of the 12 fin vaporizer, it was formed the most at the atmospheric temperature of 25℃, and the least was formed in the vaporizer at the 0℃ condition of the atmospheric temperature of 8 fins.