Fin and Temperature Effect of Frost in Ambient Air Vaporizer

  • Lee, Seong-Woo (Graduate School of Mechanical System Engineering, Gyeongsang National University) ;
  • Choi, Sung-Woong (Department of Mechanical System Engineering, Gyeongsang National University)
  • 투고 : 2022.03.02
  • 심사 : 2022.08.04
  • 발행 : 2022.08.31

초록

Since liquefied natural gas (LNG) is imported in a liquid state of about -162℃ to increase transportation efficiency in Korea, it must be vaporized in a gaseous state to supply it to consumers. Among them, ambient air vaporizer (AAV) has caught attention due to eco-friendly and low costs characteristics. However, there is a disadvantage that the performance of the heat exchanger is deteriorated due to frost due to mist and icing when used for a long time. In this paper, frost generation model in AAV vaporizer was investigated with numerically to examine utilizing the vaporizer performance with the frost generation behavior. The frost generation behavior of AAV vaporizers was examined with humidity, fin characteristic, and temperature effects. As for the LNG discharge temperature, the 12 fin vaporizer showed the highest discharge temperature when the atmospheric temperature was 25℃, and the 8 fin vaporizer had the lowest LNG discharge temperature when the atmospheric temperature was 0℃. In the case of frost formation, in the case of the 12 fin vaporizer, it was formed the most at the atmospheric temperature of 25℃, and the least was formed in the vaporizer at the 0℃ condition of the atmospheric temperature of 8 fins.

키워드

과제정보

This work was supported by the Materials/Parts Technology Development Program (20017575, Development of Applicability Evaluation Technology for Cryogenic Insulation Material and Storage Vessel considering Operating Condition of Hydrogen Commercial Vehicle) funded By the Ministry of Trade, Industry & Energy (MOTIE, Korea)

참고문헌

  1. Afrasiabian, E., Iliev, O., Lazzari, S., & Isetti, C. (2018). Numerical Simulation of Frost Formation on a Plate-Fin Evaporator. Proceedings of the 3rd World Congress on Momentum, Heat and Mass Transfer (MHMT'18) Budapest, Hungary, ICMFHT 125. https://doi.org/10.11159/icmfht18.125
  2. Fernandez, I.A., Gomez, M.R., Gomez, J.R., & Insua, A.B. (2017). Review of Propulsion Systems on LNG Carriers. Renewable and Sustainable Energy Reviews, 67, 1395-1411. https://doi.org/10.1016/j.rser.2016.09.095
  3. Hermes, C.J.L., Piucco, R.O., Barbosa Jr, J.R., & Melo. C. (2009). A Study of Frost Growth and Densification on Flat Surfaces. Experimental Thermal and Fluid Science, 33(2), 371-379. https://doi.org/10.1016/j.expthermflusci.2008.10.006
  4. Kim, J.H., Jeong, S.-W., Ahn, B.-K., Park, C.-S., & Kim, G.-D. (2018). Numerical Analysis of Unsteady Cavitating Vortex Around Two-Dimensional Wedge-Shaped Submerged Body. Journal of Ocean Engineering and Technology, 32(1), 36-42. https://doi.org/10.26748/KSOE.2018.2.32.1.036
  5. Kim, N.J., Kim, C.B., Yun, S.M., & Han, S.T. (1994). A Study on Boiling Characteristics of Direct Contact LNG Evaporator. Proceedings of the Society of Air-Conditioning and Refrigerating Engineers of Korea, 380-385.
  6. Kim, P.H., Kim, C.P., Jeong, H.M., Chung, H.S., & Lee, Y.H. (2008). Study on the Comparison of Heat Exchange Performance of Liquefied Gas Vaporizer at Super Low Temperature. Korean Journal of Air-Conditioning and Refrigeration Engineering, 20(10), 679-688.
  7. Lee, Y.K., Na, J.G., & Lee, W.B. (2018a). Robust Design of Ambient-Air Vaporizer Based on Time-Series Clustering. Computers & Chemical Engineering, 118, 236-247. https://doi.org/10.1016/j.compchemeng.2018.08.026
  8. Lee, Y.K., Park, J.M., & Han, C.H. (2018b). Modeling and Analysis of Frost Growth in Pilot-Scale Ambient Air Vaporizer. Industrial & Engineering Chemistry Research, 57(17), 5933-5943. https://doi.org/10.1021/acs.iecr.7b03480
  9. Park, S.K., & Oh, C. (2006). An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System. Journal of Navigation and Port Research, 30(1), 113-117. https://doi.org/10.5394/KINPR.2006.30.1.113
  10. Park, W.C., & Song, C.Y. (2019). Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types. Journal of Ocean Engineering and Technology, 33(4), 340-349. https://doi.org/10.26748/KSOE.2019.027
  11. Park, W.C., Song, C.Y., & Na, O.G. (2018). Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment I: Transient Thermal. Journal of Ocean Engineering and Technology, 32(5), 310-323. https://doi.org/10.26748/KSOE.2018.6.32.5.310
  12. Querol, E., Gonzalez-Regueral, B., Garcia-Torrent, J., & Garcia-Martinez, M.J. (2010). Boil off Gas (BOG) Management in Spanishliquid Natural Gas (LNG) Terminals. Appled Energy, 87(11), 3384-3392. https://doi.org/10.1016/j.apenergy.2010.04.021
  13. Rao, H.N., Wong, K.H., Karimi, I.A. (2016). Minimizing Power Consumption Related to BOG Reliquefactionin an LNG Regasification Terminal. Industrial & Engineering Chemistry Research, 55(27), 7431-7445. https://doi.org/10.1021/acs.iecr.6b01341