• 제목/요약/키워드: Panel Type

검색결과 1,205건 처리시간 0.03초

Discharge Properties of an AC-Plasma Display Panel

  • Sungkyoo Lim
    • 마이크로전자및패키징학회지
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 1998
  • Two kinds of the ac-plasma display panel (PDP) with the comb type and the matrix type electrodes were fabricated. The discharge properties were studied as a function of as species (Ne and Ne+He+Xe) and its pressure. The firing voltages (Vf) of the PDP with comb type electrodes were 159 V and 195 V under pure Ne and ne+He+Xe(68:30:2) gas mixture respectively. In case of PDP cell with the matrix type electrodes the Vf was increased to 200 V for pure Ne and 240 V for Ne+He+Xe gas mixture under the same gas pressure(300 mbar).

개량형 가동보에 적용하기 위한 하이브리드 강판/GFRP 패널 게이트의 강판게이트 표면형상에 따른 휨 및 계면 부착 특성 평가 (Flexural and Interfacial Bond Properties of Hybrid Steel/Glass Fiber Reinforced Polymer Composites Panel Gate with Steel Gate Surface Deformation for Improved Movable Weir)

  • 김기원;권형중;김필식;박찬기
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.57-66
    • /
    • 2015
  • The purpose of this study was to improved the durability of a improved movable weir by replacing the improved movable weir's metal gate with a hybrid steel/glass fiber reinforced polymer composites panel gate. Because the metal gate of a improved movable weir is always in contact with water, its service life is shortened by corrosion. This study made four type of hybrid steel/glass fiber reinforced polymer composites panel gate with different steel gate surface deformation (control, sand blast, scratch and hole), flexural. Fracture properties tests were performed depending on the steel gate surface deformation. According to the test results, the flexural behavior, flexural strength and fracture properties of hybrid steel/glass fiber reinforced polymer composites panel gate was affected by the steel panel gate surface deformation. Also, the sand blast type hybrid steel/glass fiber reinforced polymer composites panel gate shows vastly superior flexural and fracture performance compared to other types.

대면적 AMLCD의 신호 지연 감소를 위해 Air-gap을 갖는 게이트-데이터 라인 교차 구조 (A Novel Air-Bridge Type Gate-Data Line Inter-Crossing to Reduce Signal Delay for Large Size AMLCD)

  • 박진우;강지훈;이민철;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.768-772
    • /
    • 1999
  • A new TFT-LCD panel with air-bridge type gate to data line inter-crossing has been proposed and its characteristics have been measured. The proposed structure has air-gap between gate and data line inter-crossing. This air-bridge TFT-LCD panel has very small capacitance between gate and data line. The new panes structure achieves 9 times fast signal propagation compared with conventional panel, which enables to have enough design margin for 20-inch diagonal and larger size UXGA panel. We have examined thermal and mechanical durability of new panel to verify applicability for commercial AMLCD production. After TEOS and polyimide passivation, this panel withstood a thermal stress at $250^{\circ}C$ and a mechanical stress during the rubbing process.

  • PDF

도로소음원에 대한 방음패널 형상별 반사소음 저감효과 (A Reduction Effect in Noise Reflection by Different Shapes of Soundproofing-panel)

  • 김일호;박태호;장서일;이혜인
    • 대한환경공학회지
    • /
    • 제37권2호
    • /
    • pp.120-125
    • /
    • 2015
  • 도시화의 가속화와 더불어 도심의 교통량의 증가로 도로소음피해를 최소화하기 위하여 방음벽의 설치 수요가 증가하고 있다. 설치되고 있는 여러 형태의 방음벽 중, 반사형 방음패널의 경우 불투명 방음패널과 달리 시야를 가리지 않으므로 방음시설을 요구하는 거주자들에게 인기를 얻고 있다. 하지만 반사형 방음패널의 경우, 반사음에 의한 2차 피해를 유발시켜 피해를 줄일 수 있는 방음벽 개발의 필요성이 대두되고 있다. 이에 본 연구에서는 반사형 방음패널의 전면형상 및 기하학적 형태를 변화시켜 반사음의 전달을 최소화 시킬 수 있는 형상을 연구하였다. 일반형 반사형 방음패널과 형상별 방음패널의 반사소음 저감 효과를 비교 한 결과, 곡선형 방음패널이 1.5 dB의 소음저감 효과가 있었다. 또한, 반사음의 증가 또는 감소는 형상별 설계인자에 따라 변화하는 것을 알 수 있었다. 이러한 결과는 방음벽 전면 현상에 따른 반사소음의 저감 기술의 가능성을 보여주는 결과라고 판단된다.

Development of an ergonomic control panel layout system and its application

  • 박성준;정의승;이상도;이동춘
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 추계학술대회논문집
    • /
    • pp.172-181
    • /
    • 1995
  • A control panel layout system was developed to generate an ergrnomically sound panel design. A constraint satisfaction concept was introduced as a framework of incorporating diverse ergonomic design guidelines into the panel layout. An efficient search algorithm which can find a constraint satisfaction solution within a reasonable time was developed based on preprocess and look ahead procedures with the backjumping technique. The proto- type panel layaout system was developed on a SPARC workstation. The constraint satisfaction algorithm was programmed in C language with Motif as a GUI tool under the X-windows environment. The effectiveness of the prototype paned layout system was examined by a case study.

  • PDF

저항막식 터치 패널의 구동회로 제작 (An Implementation of Driving Circuit for Resistive Touch Panel)

  • 한형석
    • 정보통신설비학회논문지
    • /
    • 제8권1호
    • /
    • pp.36-39
    • /
    • 2009
  • In this paper, we propose a 4-wire type driving circuit for resistive touch panel which was manufactured at the lab. The circuit is designed by using the touch panel controller ADS7846 and AVR microcontroller board. The test result shows that the designed circuit can give and transmit the position information of touch panel to the computer.

  • PDF

P.C. 대형판 구조의 수평접합부 압축거동에 관한 실험적 연구 (Experimental Study on the Compressive Behavior of Horizontal Joint in Precast Concrete Large Panel Structure)

  • 조양호;이한선;김현산
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.19-24
    • /
    • 1994
  • Four types of horizontal joint were tested to investigate the difference with regards to the compressive behavior and strength. These include wedge-type joints (i)with and (ii)without transverse reinforcement against splitting failure of the panel concrete, and wedge-type joints (iii)with different widths of joint concrete (6cm vs 8cm) and (iv)closed platform joint. It was shown that the compressive strength of wedge-type joint is about 10% higher than that of closed-type (platform) joint. But the effect of transverse reinforcement and joint concrete widths on the strength of the joints turned out be negligible. Also, the moduli of elasticity in panel and joint are compared and the equivalent moduli of the whole wall are derived.

  • PDF

태양열저장(太陽熱貯藏)을 위한 평판형잠열축열장치(平板形潛熱蓄熱裝置)의 성능분석(性能分析) (Performance Analysis of a Panel Type Latent Heat Storage Equipment for Solar Thermal Storage)

  • 김영복;주은선;윤여두;라우정
    • Journal of Biosystems Engineering
    • /
    • 제16권3호
    • /
    • pp.290-297
    • /
    • 1991
  • For the efficient utilization of the solar thermal energy to overcome the time gap between to supply and demand, an efficient heat storage technique, especially high density-latent-heat storage system, is necessary. In this study, the performance of a panel type latent heat storage equipment during heat discharging process was analyzed theoretically and experimentally. In order to find out the performance of the system, computer simulation programs were developed by finite difference method. The governing equations were constructed by two dimensional heat conduction model with moving boundary. The results of the experimental and the theoretical analysis were reasonably well agreed. The efficiencies of the double pipe type and the panel type latent heat storage equipment were compared.

  • PDF

플라스마 디스플레이 패널에서 ITO/black interlayer/Bus 전극 간의 전기저항 평가 (Evaluation of the Electrical Resistance between ITO/black interlayer/Bus electrodes in a Plasma Display Panel)

  • 문철희
    • 대한금속재료학회지
    • /
    • 제46권2호
    • /
    • pp.97-104
    • /
    • 2008
  • Black interlayer was introduced into between ITO and Bus electrodes to enhance a bright room contrast ratio of a plasma display panel. To measure the electrical resistance of the black interlayer, we designed two test patterns, type I and type II, of which type II pattern was successful. Using type II test pattern, the electrical resistance of the black interlayer was measured to be $300{\Omega}$ for $2{\mu}m$ thickness case and infinitely high for 4, $6{\mu}m$ thickness. This result shows that electrical resistance of the black interlayer in the ITO/black interlayer/Bus electrodes structure is a critical parameter which determines the electrical characteristics of the PDP.

패널법을 이용한 POD형 워터제트 추진장치의 성능해석 (Performance Analysis of POD-Type Waterjet System by Panel Method)

  • 김현열;김문찬;전호환;정석호
    • 대한조선학회논문집
    • /
    • 제41권5호
    • /
    • pp.14-20
    • /
    • 2004
  • The aim of this paper is to analyze the steady performance of POD-type waterjet system by panel method. A surface panel method is applied to the present analysis. To analyze the compound propulsor. analysis program has been developed based on a perturbation potential method. The developed code has been validated by comparing the experimental data of shrouded propeller. The validated code has been applied to the POD-type waterjet system which can be used for the propulsion of amphibious vehicle. The computed results have been compared with experimental results. which shows a good agreement between them.