• Title/Summary/Keyword: Padding

Search Result 205, Processing Time 0.027 seconds

Improving the Dyeability of Cotton Fabric with Caesalpinia sappan through Pretreatment with Gelatin (면직물의 젤라틴 전처리에 의한 소목염색의 염색성 향상)

  • Lee, Ji Youn;Jang, Jeong Dae
    • Fashion & Textile Research Journal
    • /
    • v.21 no.4
    • /
    • pp.509-514
    • /
    • 2019
  • Cotton fabrics were treated with gelatin to enhance dyeability and color strength when using Caesalpinia sappan dye. Gelatin was used as the protein and a pad-dry- cure method was used for the treatment process (2, 4, 6, 8, 10, 12, 14g/l concentration). Pretreated fabrics were mordanted with 10% alum. Fabrics were then dyed with freeze-dried sappan wood water extract powder form. Dyed samples were assessed in regards to dyeing behavior and color fastness. Comparing untreated and gelatin treated samples from the SEM images indicated that the Gelatin treatment (10g/l) resulted in an enhanced surface roughness that was relative to that of untreated cotton. Padding cotton with gelatin at 6g/l concentration afforded dyed fabrics with a 2 times increase in the K/S value over that of untreated fabrics. All dyed samples were red color with a significant enhancement in the sample color strength (K/S) being observed for pretreated samples. pH values favor dye absorption with pH 7 yielding the highest color strength. Dyeing at an elevated temperature resulted in a lower color strength and reddish-dull color. Longer dyeing times created greater color strengths for untreated and gelatin treated cotton. Increased dye concentrations resulted in higher K/S values for both gelatin treated and untreated cotton. As for color fastness, gelatin treated and untreated cotton fabrics dyed with sappan wood extract showed a relatively low rating in washing fastness (color change 1 rating), light fastness (1 rating), and rubbing fastness (wet:1-2, dry:3-4 rating).

A Study on the High Sensitivity Electrical Muscle Stimulation (EMS) Pad Using E-TEXTILE (E-TEXTILE을 이용한 고감성 전기 근육 자극(EMS)패드의 연구)

  • Yeun, Eun-Ji;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.3
    • /
    • pp.81-90
    • /
    • 2021
  • EMSCT (Electrical Muscle Stimulation Conductive Textile) is an electrical muscle stimulation pad that can compensate for ease of use and comfort, which are disadvantages of conventional hydrogel pads used in electrical muscle stimulation (EMS). With the concentration with SWCNT (Single-Walled Carbon Nanotube) and the number of impregnation processes, EMSCT was tested by giving conductivity to five fabrics (radirons, neoprene, spandex cushions, poly100%, and vergamo). The padding process with SWCNT was performed, and the alternating current measurement indicated that the most similar alternating current with hydrogel was the Vergamo fabric of SWCNT:=2:1. Furthermore, the usability evaluation of convenience, usability, and psychological satisfaction results in increased usability of EMSCT compared with conventional hydrogel pads.

The Effect of Transcranial Direct Current Stimulation on Smartphone Addiction and Stress: a randomized controlled study

  • Lee, Eunsang
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.76-81
    • /
    • 2021
  • Objective: Smartphone addiction can cause forward head posture, carpal tunnel syndrome and depression, and anxiety. Various interventions have been proposed to resolve Smartphone addiction. However, research regarding the efficacy of these interventions remains lacking. This study was conducted to investigate the effect of tDCS (Transcranial Direct Current Stimulation) on smartphone addiction solution and stress reduction. Design: A randomized controlled trial. Methods: The participants were divided randomly into two group (tDCS vs. Control). tDCS was applied to 41 adults (22.95±2.76 years). The tDCS group was applied 2 mA, for 13 minutes twice over a 26 minute period (n1 = 21). The control (n2 = 20) was not applied after padding and was applied twice for 13 minutes over a 26 minute period. This study was conducted four times a week for a total of four weeks. Results: Smartphone addiction for tDCS showed significant improvement in the results in the S-score (p<0.05, 95% CI: 0.702, 4.922), and the result of heart rate (HR) and skin conductivity (SC) to stress. The tDCS group and control group showed no significant decrese in the results in the HR (p>0.05, 95% CI: -3.390, 8.332), but tDCS group showed significant decrese in the results in the SC (p<0.05, 95% CI: 0.060, 1.343) Conclusions: This study suggected that smartphone addiction treatment and decreses of stress. The use of tDCS will reduce the addiction rate of adults and reduce stress, so that possible side effects in society can be solved.

3D-Distortion Based Rate Distortion Optimization for Video-Based Point Cloud Compression

  • Yihao Fu;Liquan Shen;Tianyi Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.2
    • /
    • pp.435-449
    • /
    • 2023
  • The state-of-the-art video-based point cloud compression(V-PCC) has a high efficiency of compressing 3D point cloud by projecting points onto 2D images. These images are then padded and compressed by High-Efficiency Video Coding(HEVC). Pixels in padded 2D images are classified into three groups including origin pixels, padded pixels and unoccupied pixels. Origin pixels are generated from projection of 3D point cloud. Padded pixels and unoccupied pixels are generated by copying values from origin pixels during image padding. For padded pixels, they are reconstructed to 3D space during geometry reconstruction as well as origin pixels. For unoccupied pixels, they are not reconstructed. The rate distortion optimization(RDO) used in HEVC is mainly aimed at keeping the balance between video distortion and video bitrates. However, traditional RDO is unreliable for padded pixels and unoccupied pixels, which leads to significant waste of bits in geometry reconstruction. In this paper, we propose a new RDO scheme which takes 3D-Distortion into account instead of traditional video distortion for padded pixels and unoccupied pixels. Firstly, these pixels are classified based on the occupancy map. Secondly, different strategies are applied to these pixels to calculate their 3D-Distortions. Finally, the obtained 3D-Distortions replace the sum square error(SSE) during the full RDO process in intra prediction and inter prediction. The proposed method is applied to geometry frames. Experimental results show that the proposed algorithm achieves an average of 31.41% and 6.14% bitrate saving for D1 metric in Random Access setting and All Intra setting on geometry videos compared with V-PCC anchor.

Comparison of Patients Satisfaction with Direct to Implant versus Latissimus Dorsi Flap with Implant Breast Reconstruction Using Breast-Q

  • Ji Min Kim;Woo Jin Song;Sang Gue Kang
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.710-715
    • /
    • 2022
  • Background The latissimus musculocutaneous flap (LD flap) is a useful option for breast reconstruction following mastectomy. It has the advantage of obtaining sufficient tissue padding and natural shape by using autologous tissue. However, with the emergence of the skin-sparing mastectomy technique and artificial dermis matrix, direct-to-implant (DTI) breast reconstruction has become the first choice of surgery. The purpose of this study was to compare the satisfaction levels of patients who underwent DTI and LD flap with implant using patient-reported Breast-Q results. Methods A retrospective study was performed reviewing the records of 49 women who underwent immediate breast reconstruction with DTI or LD flap with implant and responded to the BREAST-Q questionnaire after the operation. The patient-reported breast-Q results were analyzed and correlated to the demographic information and intraoperative information. Results A total of 26 patients who underwent reconstruction with LD flap with implant and 23 patients with DTI were identified and responded to the questionnaire after an average of 32.3 and 10.4 months postoperation, respectively. According to the patient response to the breast-q values, satisfaction with breast was 60.0 and 57.0 points, psychosocial well-being 61.0 and 60.0 points, and sexual well-being 41.0 and 43.0 points in the two groups. Overall, there was no significant difference in the breastQ score between the two groups. Conclusion Patients who underwent DTI breast reconstruction seemed equally satisfied with the appearance and outcome of their breast reconstruction compared with LD flap with implant. Therefore, it appears that DTI is adequately replacing LD with implant.

Comparison of Augmentation Method for Achilles Tendon Repair: Using Thoracolumbar Fascia and the Polypropylene Mesh

  • Jieun Seo;Won-Jae Lee;Min Jang;Min-Soo Seo;Seong Mok Jeong;Sae-Kwang Ku;Youngsam Kwon;Sungho Yun
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.16-24
    • /
    • 2023
  • This study aimed to compare complete ruptured tendon healing between two different repair methods using the Achilles tendon of New Zealand white rabbits. Thoracolumbar fascia (TF) padded Kessler suture, polypropylene mesh (PM) padded Kessler suture, and Kessler suture only were performed on the completely transected lateral gastrocnemius tendon, and biomechanical and histologic characteristics were assessed after 8 weeks. For biomechanical assessment, the tensile strength of each repaired tendon was measured according to the established methods. For histomorphometric analysis, hematoxylin and eosin staining for general histology, and Masson's trichrome (MT) staining for collagen fibers, Alcian blue (AB) staining for proteoglycans were performed and analyzed. Significant increases in tensile strength with remarkable decreases in the abnormalities against nuclear roundness, cell density, fiber structure, and fiber alignment and significant decreases in the mean number of infiltrated inflammatory cells and AB-positive proteoglycan-occupied regions with increases in MT-positive collagen fiber-occupied regions were demonstrated in the Kessler suture with PM or TF padding groups as compared to those of the Kessler suture group. Both of PM and TF provided potent tensile strength and supported healing with the evidence of histological examinations. This means that augmentation with PM is useful for repairing a completely ruptured Achilles tendon, without additional surgery for autograft material harvesting.

Keyhole Imaging Combined Phase Contrast MR Angiography Technique (Keyhole Imaging기법을 적용한 위상대조도 자기공명 혈관조영기법)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.72-77
    • /
    • 2012
  • Phase Contrast MR Angiography(PC MRA) is excellent MRA technique for measuring the velocity of vessels in the human body. PC MRA need to at least four images for angiogram reconstruction and it caused longer scan time. Therefore, we used keyhole imaging combined PC MRA to reduce the scan time. However, keyhole imaging can lead the erroneous effects as loss of phase information or frequency discontinuous. In this study, we applied the keyhole imaging combined 2D PC MRA for improving the temporal resolution and also measured the velocity to evaluate the accuracy of phase information. We used 0.32T MRI scanner(Magfinder II, Scimedix, Korea). Using the 2D PC MRA pulse sequence, the vascular images for a human brain targeted on the Superior Sagittal Sinus(SSS) were obtained. We applied tukey window function for keyhole images to minimize the ringing artifact and erroneous factors that are induced frequency discontinuous and phase information loss. We also applied zero-padded algorithm to peripheral missing k-space lines to compare keyhole imaging results and the artifact power(AP) value was measured on the complex difference images to validate the image quality. Consider as based on our results, heavy image distortions and artifacts were shown until using at least 50% keyhole factor. Using above the 50% keyhole factors are shown well reconstructed and matched for magnitude images and velocity information measurements. In conclusion, we confirmed the image quality and velocity information of keyhole technique combined 2D PC MRA. Especially, measured velocity information through the keyhole imaging combination was similar to the velocity information of full sampled k-space image despite of frequency discontinuous and phase information loss in the keyhole imaging reconstruction process. Consequently, the keyhole imaging combined 2D PC MRA will give some clinical usefulness and advantages as improving the temporal resolution and measuring the velocity information via selecting the appropriate keyhole factor at low tesla MRI system.

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

A Study on Dynamic Moisture Transfer in Textiles Using Cobaltous Chloride Method (염화코발트법을 이용한 직물의 동적 수분전달에 대한 연구)

  • Hong Kyunghi;Kim Eunsook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.4
    • /
    • pp.400-411
    • /
    • 1989
  • Moisture related properties of fabrics in dynamic modes are considered to be important in the judgement of the subjective comfort characteristics of clothing fabrics. In the current study, an attempt to improve the cobaltous chloride test method was made which has been known as a convenient screening test for dynamic surface wetness. The color changes of cobaltous chloride treated fabrics on the simulated sweating skin were calibrated against standard color strips. The standard color strips were made of all typs of test fabrics and installed inside of the test tubes containing a series of saturated salt solutions, which gives more quantitative informations on dynamic moisture transfer Influences of fiber types and finishes on dynamic moisture transfer in textiles were studied using a single layer of fabric samples. Fiber types included $100\%$ cotton, C/P 50/50, C/P 35/65. Durable press and soil release finished cotton and C/P 50/50 fabrics were also included. There were significant fiber effects on the dynamic moisture transfer. The order of time taken to reach to the specified $\%$ RH was C/P 35/65$100\%$ cotton fabrics. It was possible to detect significant finish effects by increasing the concentrations of cobaltous chloride solutions. The order of time taken to reach to the specified $\%$ R.H was durable press$100\%$ cotton, C/P 50/50, C/P 35/65 and $100\%$ PET were placed at the inner side of the outer layer and tested. It was shown that cobaltous chloride treated $100\%$ cotton fabirc was easier to detect color changes than C/P blend fabic in the double layer experiments. By placing test sample under the cobaltous chloride treated cotton fabrics, it was able to detect the differences among the test samples, some of which were known to be difficult in padding with cobaltous chloride solutions. Besides, the double layer method would provide with the broader application of the cobaltous chloride method in !uture, since it is possible to test the dynamic moisture transfer of clothing as worn.

  • PDF

Quantification of Thermal Insulation by Clothing Items and Analysis of Influencing Factors (단일의복의 보온력 정량화와 영향 요인)

  • Baek, Yoon Jeong;Hwang, Soo Kyung;Lee, Hyo Hyun;Park, Joonhee;Kim, Do-Hee;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.1
    • /
    • pp.172-182
    • /
    • 2018
  • The purpose of the present study was to quantify the thermal insulation of garments by item and examine factors influencing clothing insulation. A total of 769 garments in clo unit were collected and classified into 12 categories: blouses/shirts (95 items, BS), T-shirts/sweaters (62 items, TS), vest (23 items, VT), cardigans (23 items, CD), jackets/coats (75 items, JC), sport outerwear (including padding jackets)(48 items, SO), trousers (23 items, TR), skirts (56 items, SK), dresses (28 items, DS), underwear (150 items, UW), sleepwear (50 items, SW), and personal protective clothing (59 items, PPC). The results showed that clothing insulation was $0.21{\pm}0.01clo$ for the BS, $0.22{\pm}0.01clo$ for TS, $0.12{\pm}0.00clo$ for VT, $0.23{\pm}0.02clo$ for CD, $0.40{\pm}0.02clo$ for JC, $0.49{\pm}0.03clo$ for SO, $0.21{\pm}0.01clo$ for TR, $0.18{\pm}0.01clo$ for SK, $0.34{\pm}0.03clo$ for DS, $0.09{\pm}0.01clo$ for UW, $0.42{\pm}0.03clo$ for SW, and $0.56{\pm}0.03clo$ for PPC (p<.001). The most influential factors among the seven factors for thermal insulation of garments were clothing weight and covering area; however, the explanatory powers of two factors differed according to clothing categories. The covering area had more significant impact on clothing insulation in cardigans, jackets/coats, trousers, and dresses than clothing weight. Covering areas and clothing weight were the most influential factors in the following categories: blouses/shirt, T-shirts/sweaters, skirts, sleepwear and personal protective clothing. The garment weight was the most important factor for thermal insulation for the sport outerwear.