• 제목/요약/키워드: PVS

검색결과 128건 처리시간 0.025초

Visualizing the Peripheral Primo Vascular System in Mice Skin by Using the Polymer Mercox

  • Stefanov, Miroslav;Kim, Jungdae
    • 대한약침학회지
    • /
    • 제18권3호
    • /
    • pp.75-79
    • /
    • 2015
  • Objectives: As the peripheral part of the primo vascular system (PVS) is difficult to visualize, we used a vascular casting material Mercox injected directly into the skin to take advantage of a simple procedure to visualize PVS structures as primo vessels (PVs) and primo nodes (PNs) in the skin. Methods: Two colors of the polymer Mercox were injected into mouse skin. After a partial maceration of the whole body with potassium hydroperoxide solution, we anatomized it under a stereomicroscope to trace the Mercox that had been injected into the PVS. Results: Injection of Mercox directly into the skin allowed the PVs and the PNs to be visualized. This approach can fill the PVS when the material is ejected out of the PVs or PNs. The shapes, sizes, and topographic positions of the nodes and the vessels are the hallmarks used to identify the PVS in skin when Mercox is used as a tracer. Conclusion: The direct injection of the casting material Mercox into skin, with modified partial maceration procedures, is a promising method for visualizing the PVs and the PNs in the peripheral part of the PVS in skin. The polymer Mercox can penetrate through the primo pores of the primo vascular wall and fill the PVs and the PNs. The data prove that PVs and PNs exist on the hypodermal layer of the skin.

솜양지꽃(Potentilla discolor Bunge)의 초저온동결보존을 위한 최적 조건 탐색 (Optimization Conditions for Cryopreservation of Potentilla discolor Bunge)

  • 양우형;용성현;박동진;설유원;최은지;정미진;최명석
    • 한국산림과학회지
    • /
    • 제107권3호
    • /
    • pp.258-265
    • /
    • 2018
  • 본 연구는 희귀자생식물인 솜양지꽃의 효율적인 초저온 보존 조건을 탐색하고자 행하였다. 종자의 활력은 PVS2와 PVS3 용액 처리구에서는 약 80% 이상으로 대조구보다 훨씬 높은 활력을 보였다. 종자의 활력은 PVS3가 PVS2 처리보다 높게 나타났다. 종자의 활력은 sucrose처리에도 불구하고 대조구보다 낮았다. PVS2의 60분 처리구와 PVS3의 30분 처리구에서 95%의 발아율을 보였으나 그 외 처리구에서는 발아율이 낮았다. PVS2와 PVS3 처리구에서 배양된 유묘의 생장은 PVS2와 PVS3 용액 30분 처리구를 제외하고는 대조구에 비해 생장이 좋지 않았다. 두 가지 초저온동결보존법 간 유묘 생장에서는 encapsulation법과 vitrification법을 비교한 결과 미세한 차이를 보였으나 통계적으로는 유의성이 없었다. 본 연구는 솜양지꽃의 보존에 도움이 될 것으로 판단된다.

이진공간분할(BSP)과 잠재적가시공간(PVS) 알고리즘을 이용한 실내렌더링 속도개선 방법 (An Improvement Method of Indoor Rendering Speed Using BSP and PVS Algorithms)

  • 김병선;권순각;김성우;이중화;정재진
    • 한국멀티미디어학회논문지
    • /
    • 제11권1호
    • /
    • pp.88-95
    • /
    • 2008
  • 본 논문에서는 이진공간분할(BSP), 잠재적가시공간(PVS) 알고리즘을 이용한 효과적인 실내렌더링 방법을 제시한다. 제안된 방식은 BSP 알고리즘과 PVS 기법을 동시에 이용하여 BSP 영역번호를 나누는 과정에서 BSP 영역에 오브젝트를 추가로 포함시킴으로써 오브젝트를 효과적으로 출력시킨다. 또한, 플레이어 위치를 중심으로 PVS를 검사하여 필요한 부분만 출력시킨다. 실험 결과로 부터 제안된 기법은 BSP와 PVS를 경계영역뿐만 아니라 오브젝트도 같이 처리함으로써 렌더링 속도가 향상됨을 보인다.

  • PDF

감자 바이러스의 혈청학적 동정에 관한 연구 (Serological Identification of Potato Viruses in Korea)

  • 나용준
    • 한국응용곤충학회지
    • /
    • 제13권1호
    • /
    • pp.41-45
    • /
    • 1974
  • 우리나라 씨감자에 발생하고 있는 잠복성바이러스의 종류와 이들의 감염상태를 조사하기 위하여 감자 원원종포, 원종포 그리고 원예시험장 등에서 수집한 외관상 무병 건전하게 보이는 감자와 외관상 바이러스병징이 뚜렷한 감자를 대상으로 혈청학적방법에 의해 바이러스 검정을 실시했다. 검정대상 바이러스는 Potato Virus X(PVX), Potato Virus S(PVS), Potato Virus M(PVM), 그리고 Potato Virus Y (PVY)의 4종이며, 바이러스의 검정은 van Slogteren의 미량침강법에 따라 실시했다. 결과는 다음과 같다. 1. 씨감자 생산포장에서 수집한 감자잎에서 PVX, PVS, PVM, 그리고 PVY가 검출되었는데 우리나라 감자에서 PVM이 검출되었다는 실험적 보고는 이것이 처음이다. 2. 외관상 건전하게 보이는 씨감자의 거의 $100\%$ PVX와 PVS에 약 $10\%$가 PVX+PVS+PVM에, 약 $4.5\%$가 PVX+PVS+PVY에, 그리고 $1\%$ 정도가 PVX+PVS+PVM+PVY에 각각 혼합감염되어 있었다. 3. PVX와 PVS만이 검출된 식물은 대부분 병징이 음폐되어 있었으나 PVX, PVS와 함께 PVY가 검출된 식물은 대부분 뚜렷한 병징을 나타내고 있었다. 4. 혈청학적 미량탐강법은 육안적인 관찰만으로는 검정이 어려운 PVX, PVS, PVM 및 mild strain의 PVY를 씨감자 생산지에서 대규모의 식물은 대상으로 신속정확히 검정하는데 애우 편리한 방법으로 생각된다.

  • PDF

패시브환기외피의 단면온도분포 및 열회수량에 관한 수치해석적 연구 (A Numerical Study on Sectional Temperature Distribution and Heat Recovery Amount of Passive Ventilation Skin)

  • 이태철;손유남;윤성환
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.705-710
    • /
    • 2012
  • This study aims to analyse changes of inner temperature of PVS(Passive ventilation skin) and heat recovery when it has ventilation of air through PVS using numerical simulation in the winter condition. Results are as follows. 1) In case of the air inflows through PVS, change of inner temperature of PVS is lower than in case of the air flows inner space to out space, by dynamic insulation. 2) It was identified that the temperature gradient of PVS were bigger by increases of ventilation amount. To reduce ventilation load, heat transfer efficiency at the inner side of PVS is important and what performance of insulation at the inner side of PVS secure helps to improve heat performance of all PVS.

정전위 전해 중합법에 의한 폴리피롤 제조 및 전기화학적 특성 (Preparations and Electrochemical Characteristics of Polypyrrole by Constant Potential Electroplymerization)

  • 조승구;심철호
    • 전기화학회지
    • /
    • 제8권2호
    • /
    • pp.99-105
    • /
    • 2005
  • 본 연구에서는 정전위 전해중합법으로 음이온 크기가 다른 도펀트를 사용하여 폴리피를 전극을 제조하였으며, CV 및 교류 임피던스법을 이용한 전기화학적 분석 및 형태학적 분석을 통해 제조된 폴리피롤 전극의 특성을 고찰하였다. 제조된 전극을 전기화학적으로 분석한 결과 $PPy/CLO_4$전극은 음이온의 도핑$\cdot$탈도핑이, PPy/PVS 전극은 양이온의 탈도핑$\cdot$도핑이 일어나고 있음을 알았다. 합성 전위가 증가할수록 $PPy/CLO_4$ 전극과 PPy/PVS 전극 모두 전하전달저항은 감소하였고, 이중층 용량은 $PPy/CLO_4$전극이 PPy/PVS 보다 큼을 알 수 있었다. 합성 전위 변화에 따른 PPy/PVS 전극 표면의 변화는 상대적으로 $PPy/CLO_4$ 보다 작음을 알 수 있었다

PVS를 이용한 수정된 BLP 모델의 안전성 검증 (A Safety Verification of the Modified BLP Model using PVS)

  • 구하성;박태규;송호근
    • 한국정보통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.1435-1442
    • /
    • 2006
  • 안전성에 대한 이상적인 평가방법은 운영체제내의 모든 가능한 연산을 대상으로 실행 결과의 안정성 여부를 검사하는 것이다. 하지만 이는 현실적으로 불가능하다. 그러나 정형기법을 사용할 경우 운영체제 동작논리상의 안전성 보장 여부를 이론적으로 증명할 수 있다. 따라서 본 논문에서는 보안커널의 안정성 검증방법에 대하여 논하고, 정형검증의 대표적인 도구들에 대하여 비교분석을 수행하였다. 그리고 보안커널에 기반한 다중레벨 접근통제모델인 수정된 BLP(Bell & LaPadula) 모델을 검증하기에 적합한 PVS(Prototype Verification System) 검증도구를 선정하였다. 마지막으로 PVS 검증도구를 활용하여 정형명세를 작성하고, 작성된 정형명세의 검증을 통하여 수정된 BLP 모델이 안전한 보안모델이라는 것을 검증하였다.

실내 3D 게임 장면의 잠재적 가시 집합을 위한 효과적인 하드웨어 압축 구조 (An Effective Structure of Hardware Compression for Potentially Visible Set of Indoor 3D Game Scenes)

  • 김영식
    • 한국게임학회 논문지
    • /
    • 제14권6호
    • /
    • pp.29-38
    • /
    • 2014
  • 대규모 실내 3D 게임 장면에서 차폐 컬링 정보를 미리 계산하는 잠재적 가시 집합(potentially visible set: PVS)은 데이터를 처리하고 저장해야하는 양이 상당히 크지만 많은 부분이 0으로 표현된다. 본 논문에서는 모바일 환경의 3D 게임 장면 트리 구성 중에 PVS 데이터를 ZRLE (zero run length encoding) 방식으로 압축하는 효과적인 하드웨어 압축 구조를 설계한다. 3D 게임 시뮬레이션을 통하여 제안하는 구조의 PVS 데이터 압축 비율, PVS 컬링과 절두체 컬링에 따른 렌더링 속도 (frame per second: FPS)를 분석하였다.

늘어난 혈관주위공간: 노화와 신경계질환에서의 임상적의의와 영상의 역할 (An Enlarged Perivascular Space: Clinical Relevance and the Role of Imaging in Aging and Neurologic Disorders)

  • 임영희;문원진
    • 대한영상의학회지
    • /
    • 제83권3호
    • /
    • pp.538-558
    • /
    • 2022
  • 혈관주위공간(perivascular space; 이하 PVS)는 뇌 실질을 관통하는 세동맥 둘러싸고 있는 공간으로, 최근에는 별아교세포의 종족(astrocyte endfoot)에 의해 가장 바깥쪽이 경계지워지는, 체액, 세포, 결합조직으로 구성된 혈관벽내, 혈관벽 주위의 구획을 모두 아우르는 개념으로 이해하고 있다. 정상적으로는 현미경적 해부학 구조물이지만 이 구조물이 늘어나게 되면 MRI T1 혹은 T2 이미지에서 확인할 수 있게 된다. PVS의 명확한 실체나 임상적인 의의에 대해서는 아직 분명치 않은 부분이 많이 있지만 PVS의 확장(enlarged PVS; 이하 EPVS)은 다양한 퇴행성 뇌질환 뿐만 아니라 뇌출혈 및 외상성 뇌손상, 당뇨성 신질환 같은 다양한 질병과의 연관성이 있다는 연구 결과들이 발표되고 있다. 이번 종설에서는 PVS와 EPVS가 가지는 임상적 의의와 병태 생리에 대한 최근 문헌을 고찰하고, MRI를 이용한 정성적 평가 및 최적화에 대해 논의해 보고자 한다.

패시브환기외피의 통기성능 및 열관류율에 대한 연구 (A Study on Ventilation and Heat Transfer Coefficient of Passive Ventilation Skin)

  • 이태철;손유남;윤성환
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.679-684
    • /
    • 2012
  • This paper aims to evaluate performances of ventilation and insulation of 6types PVS(Passive ventilation skin) by numerical simulation. The results are as follows. 1) The result of Performance of ventilation by pressure difference, it was shown that the amount of ventilation changed bigger under 1Pa and amount of ventilation increased according to increase opening area (${\alpha}A$). Although same opening area of PVS, it can predict that pressure differences cause ventilation differences. 2) In case of same opening area of PVS, however, it was changed the amount of ventilation each types of PVS that is distinguished opening area by flow coefficient. 3) Dynamic U-value that represents performance of insulation PVS was similar change upper ${\alpha}A40\;cm^2/m^2$, great change in casse of 0.1 Pa pressure difference. In case of ${\alpha}A10\;cm^2/m^2$, it was changed bigger under 0.3 Pa pressure difference, ${\alpha}A20\;cm^2/m^2$ of PVS was changed under 0.2 Pa pressure difference.