실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교 (An Experimental Study of Performance Improvement of Air Type PV/T Collector Units)

  • 김진희;양연원;김준태
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

태양광모듈의 모델링 및 성능향상을 위한 최적구성방안에 관한 연구 (A study on the Optimal Configuration Algorithm for Modeling and Improving the Performance of PV module)

  • 정종윤;최성식;최홍열;유상원;이인철;노대석
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.723-730
    • /
    • 2016
  • 태양광 모듈은 필요한 발전량을 얻기 위해 태양 전지를 직렬과 병렬로 조합하여 구성하며, 이 모듈은 일사량 및 온도에 따라 발전성능이 크게 좌우되는 특성을 가지고 있다. 또한, 태양광 전원은 건물 또는 나무 등의 주변 환경에 의한 음영과 같은 특수한 상황에 의하여 출력손실이 발생하게 된다. 즉 태양광 전원을 구성하는 태양광 모듈 일부에 부분음영이 발생할 경우, 태양광 모듈의 단락전류가 제한되어 전체 발전량 손실을 초래하고, 열점(Hot-Spot) 현상과 같은 열화현상이 발생하여 모듈의 수명을 단축시킨다. 따라서 본 논문에서는 태양광 모듈의 출력을 향상시키기 위한 태양전지와 바이패스 다이오드의 최적구성 알고리즘을 제시하였다. 또한, 부분 음영에 의한 출력손실을 최소화하기 위하여 태양광 어레이의 회로를 최적으로 구성하는 알고리즘을 제시하였다. 상기 알고리즘을 바탕으로 회로해석 프로그램인 PSIM S/W를 이용하여 태양광 모듈과 태양광 어레이를 모델링하여 시뮬레이션을 수행하였다. 그 결과, 본 논문에서 제안한 태양 전지와 바이패스 다이오드의 최적구성 알고리즘과 태양광 어레이의 최적구성 알고리즘이 태양광 전원의 성능 향상에 유용함을 확인하였다.

염전 병행 태양광 발전 시스템 타당성 검토를 위한 기초연구 (Feasibility Study of Salt Farm and Solar Power Paraell System)

  • 강성현;김봉석;김근호;박종성;김덕성;임철현
    • Current Photovoltaic Research
    • /
    • 제9권1호
    • /
    • pp.17-21
    • /
    • 2021
  • In this study, the effect of water level and temperature on the power generation was investigated in a water tank with an aquavoltaic PV module to perform feasibility research for the development of salt farm aquavoltaic system. The silicon solar cell attached to the bottom of each water tank is a 1-cell mini module, and the underwater effects of the crystal phase (19.0~19.9% of single- & 17.9~19.9% of poly-crystalline) of the PV module were investigated, and power generation characteristics for water level (0~10 cm) and temperature (10~40℃) were analyzed. The deterioration coefficients according to the water level and temperature of each single- and poly-crystalline module were investigated at very similar levels such as, -2.01 %/cm and -2.02 %/cm, -0.50 %/℃ and -0.48 %/℃, respectively. Therefore, in salt farm aquavoltaic system, water levels need to maintain as low as possible, and heat-induced degradation is similar to those shown in general land, and no factors have been found to be affected by the underwater environment depending on the determination.

태양전지모듈 후면의 냉각조건에 따른 조립식 건축자재와 일체화에 관한 연구 (A Study on the Integrated Prefab Building Materials Depending on the Cooling Type of PV Module Backside)

  • 이소미;이용호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.138-141
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre-manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, the purpose of this research is to integrated prefab building materials depending on the cooling type of PV modules. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module temperature. From the basis of these results on the correlation of temperature and irradiation were obtained.

  • PDF

진동형 히트파이프 흡열판이 결합된 하이브리드 태양광/열 시스템 (Hybrid Photovoltaic/Thermal Solar System with Pulsating Heat Pipe Type Absorber)

  • 김창희;전동환;공상운;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2148-2153
    • /
    • 2007
  • The electricity conversion-efficiency of solar cell for commercial application is about 6-15%. More than 85% of the incoming solar energy is either reflected or absorbed as heat energy. Consequently, the working temperature of the photovoltaic cells increases considerably after prolonged operations and the cell's efficiency drops significantly. PV/T refers to the integration of a PV module and a solar thermal collector in a single piece of equipment. By cooling the PV module with a fluid steam like air or water, the electricity yield can be improved. At the same time, the heat pick-up by the fluid can be to support space heating or service hot-water systems. In this study, a pulsating heat pipe solar heat collector was combined with single-crystal silicon photovoltaic cell in hybrid energy-generating unit that simultaneously produced low temperature heat and heat and electricity. This experiment was investigating thermal and electrical efficiency for evaluation of a PV/T system.

  • PDF

Cold facade형 BIPV시스템의 발전성능 분석 (Analysis of Performance of Building Integrated PV System of Cold Facade type)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.275-280
    • /
    • 2008
  • Photovoltaic(PV) permit the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of BIPV system of cold facade type and analyzed of performance of BIPV system of cold facade type. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 73.1%.

  • PDF

태국 열대몬순기후 조건에서 PV모듈 기술별 성능특성 비교 연구 (Comparative Study on Performance of Grid-Connected Photovoltaic Modules in Tropical Monsoon Climate under Thailand condition)

  • 김승덕;고병욱;박진희;천대인
    • 신재생에너지
    • /
    • 제10권3호
    • /
    • pp.39-46
    • /
    • 2014
  • The performances of three different types of photovoltaic (PV) module technologies namely, copper-indium-diselenide (CIGS), mono-crystalline silicon (mo-Si) and amorphous silicon (a-Si) have been comparatively studied in the grid-connected system for more than a year under the tropical monsoon climate of Thailand. The yields, performance ratios and system efficiencies for the respective PV module technologies have been calculated and a comparison is presented here. The performance ratios of the initial operation year for CIGS showed highest among the compared technologies under Thailand climate conditions by marking 97.0% while 89.6% for a-Si and 81.5% for mo-Si. Although mo-Si has shown highest efficiencies all over the period, under the testing conditions, the operating efficiency of mo-Si was down-graded from its reference value mainly due to high operating temperature and the efficiency of the tested CIGS module was also found as high as that of mo-Si in the study. Accordingly, outdoor assessment shows that CIGS modules have demonstrated high performance in terms of yields and performance ratios in Thailand climate conditions.

GSIKGL M. L. P 통신에 의한 P. I. D 제어 특성에 관한 연구 (A Study on the Characteristic of P. I. D Control with M. L. P Communication in GSIKGL)

  • 위성동;오수홍;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.91-100
    • /
    • 2000
  • An operating principle of PID module was implemented using the load, where the integer in a PID measuring derivate equation were valid in the ranges of 500-9000, 60-1000, and 000-9000, for P, I and D, respectively. A load operation program was designed to investigate the PID theory and its realization process. With it, it was examined the process that the current PV tracts the target SV, By investigating the time when the PV approaches the SV and the rate at which the EV is varied, it is revealed that 1) larger (or Smaller) Kp leads to faster (or slower) approaching of PV to SV, 2) smaller (or larger) Ti results in faster (or slower) approaching of PV to SV, 3) larger (or smaller)$T_d$ causes smaller (or Larger) rate variation in the EV. These observation were found to coincide with those of PID operating characteristics. Though this implementation, it is known for the widespread use of PID module that an improvement should be made in the error of temperature. This, meanwhile, implies that the computational time of conventional manipulation valve must be faster than 0.1 second. It is demanded that an improved PID module including the A/D and D/A module, in itself must be used in conjunction with PLC.

  • PDF

Photovoltaic module의 발전 온도에 따른 EVA 광 특성 연구 (A Study on EVA Optical Characteristics By Generation Temperature of PV module)

  • 우성철;정태희;민용기;강기환;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.31-35
    • /
    • 2011
  • Photovoltaic modules are well known to be one of the most eco generation of electricity. But usually study solar cell. Otherwise, PV modules are also important in power generation. We have to check other subsidiary materials. In this work benefit of using optically superior encapsulation materials(EVA) in generation temperature is demonstrated. Optical characterization of three EVA products demonstrates reduced transmission in the visible ray region of the solar spectrum. It will have a decisive effect to the module efficiency. Test is shown reduction of reflectance and transmittance. Reflections is dependent on the low iron glass. It can be seen between a specific wave length(240~350mm) about 1%. Transmittance in the entire ray region of light is markedly reduced to depending on the temperature rise. The graph is shown optical properties on EVA. Transmission was reduced. about 1%.

  • PDF

액체식 PVT 복합모듈의 유형별 성능 비교 분석 (The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules)

  • 김진희;강준구;김준태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.