• 제목/요약/키워드: PV String

검색결과 50건 처리시간 0.023초

계통연계형 멀티스트링 태양광 발전 시스템 (Photovoltaic Multi-string PCS with a Grid-connection)

  • 권정민;김응호;남광희;권봉환
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.69-76
    • /
    • 2007
  • In this paper, a PV multi-string PCS with a grid-connection is proposed. An improved MPPT algorithm for the PV multi-string PCS is suggested. Each PV string has its own MPP tracker and the proposed MPPT algorithm prevents LMPP tracking due to power ripple. In the PV PCS with single-phase inverter has a large current ripple at twice the grid frequency. The current ripple reduction algorithm without external component is suggested. Also, this paper proposes a simple control method to achieve sharing of the PV string voltage and current among the interleaved parallel boost converters. All algorithms and controllers are implemented on a single-chip microcontroller. Experimental results obtained on a 3kW prototype show high performance of the proposed PV multi-string PCS.

  • PDF

계통연계형 멀티스트링 태양광 발전 시스템 (Photovoltaic Multi-string PCS with a Grid-connection)

  • 권정민;김응호;권봉환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.255-258
    • /
    • 2007
  • In this paper, a PV multi-string PCS with a grid-connection is proposed. An improved MPPT algorithm for the PV multi-string PCS is suggested. Each PV string has its own MPP tracker and the proposed MPPT algorithm prevents LMPP tracking due to power ripple. In the PV PCS with single-phase inverter has a large current ripple at twice the grid frequency. The current ripple reduction algorithm without external component is suggested. Also, this paper proposes a simple control method to achieve sharing of the PV string voltage and current among the interleaved parallel boost converters. All algorithms and controllers are implemented on a single-chip microcontroller. Experimental results obtained on a 3kW prototype show high performance of the proposed PV multi-string PCS.

  • PDF

Jerk 함수를 적용한 태양광 스트링 내의 노후화 모듈 검출 기법 (Detection of Aging Modules in Solar String with Jerk Function)

  • 손한별;박성미;박성준
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.356-364
    • /
    • 2019
  • In this study, major problems, such as licensing problems due to civil complaints, deterioration of facility period, and damage of modules, are exposed to many problems in domestic businesses. Particularly, the photovoltaic (PV) modules applied to early PV systems have been repaired and replaced over the past two decades, and a new module-based aging detection method is needed to expand the maintenance market and stabilize and repair power supplies. PV modules in a PV system use a string that is configured in series to generate high voltage. However, even if only one module of the solar modules connected in series ages, the power generation efficiency of the aged string is reduced. Therefore, we propose a topology that can measure the instantaneous PV characteristic curve to determine the aging module in the solar string and the aging judgment algorithm using the measured PV characteristic curve.

태양광 시스템의 부정합 손실 저감을 위한 모듈 전류 보상 기법 (Compensation of PV Module Current for Reduction of Mismatch Losses in PV Systems)

  • 안희욱;박기엽
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.26-32
    • /
    • 2012
  • A current compensation method to reduce the mismatch loss in PV systems is proposed as a way to increase the power generation efficiency. A dc-dc converter is used to supply currents to irregular modules in a PV string and is powered from the string output. The converter's voltage conversion ratio is adjusted so that all the modules in the string are operated at the maximum power point. The power rating and size of the converter can be reduced since only the current difference between the regular and irregular module may be supplied. The compensated string shows very little voltage mismatch compared to other regular strings. The validity of the proposed method is verified through a simulation and experiments in a prototype PV system.

태양광 PV 스트링에서의 모듈 부정합 손실의 분석 및 개선 기법 타당성 연구 (Analysis of Module Mismatch Loss in Solar PV String and Feasibility Study for Improvement Method)

  • 안희욱
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.58-63
    • /
    • 2009
  • In this paper, the power loss due to PV module mismatch in PV string is analyzed and a mismatch compensation method is proposed to improve the efficiency of PV system. The analysis of mismatch loss using PV model simulation reveals that the mismatch module may decrease the total efficiency because the MPPT function of power conditioner make the PV system operate at the local maximum point. The mismatch loss can be severe if the maximum power point current of mismatch module is less than that of string. The proposed compensation method which is simply implemented with a buck type converter shows the possibility to remove the mismatch loss. The effectiveness of the analysis and compensation method is verified by a prototype experiment.

홀수스트링 PV모듈의 바이패스 다이오드 배치에 의한 전기적 특성 (Electrical Characteristics of PV Modules with Odd Strings by Arrangement on Bypass Diode)

  • 신우균;고석환;주영철;송형준;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.1-11
    • /
    • 2017
  • Most PV modules are fabricated by 6 cell-strings with solar cells connected in series. Moreover, bypass diodes are generally installed every 2 cell-strings to prevent PV modules from a damage induced by current mismatch or partial shading. But, in the case of special purpose PV module, like as BIPV (Building Integrated Photovoltaic), the number of cell-strings per module varies according to its size. Differ from a module employing even cell-strings, the configuration of bypass diode should be optimized in the PV module with odd strings because of oppositely facing electrodes. Hence, in this study, electrical characteristics of special purposed PV module with odd string was empirically and theoretically studied depending on arrangement of bypass diode. Here, we assumed that PV module has 3 strings and the number of bypass diodes in the system varies from 2 to 6. In case of 2 bypass diodes, shading on a center string increases short circuit current of the module, because of a parallel circuit induced by 2 bypass diodes connected to center string. Also, the loss is larger, as the shading area in the center string is enlarged. Thus, maximum power of the PV module with 2 bypass diode decreases by up to 59 (%) when shading area varies from 50 to 90 (%). On the other hand, In case of 3 and 6 bypass diodes, the maximum power reduction was within about 3 (W), even the shading area changes from 50 to 90 (%). As a result, It is an alternative to arrange the bypass diode by each string or one bypass diode in the PV module in order to completely bypass current in case of shading, when PV module with odd string are fabricated.

PV모듈에서 태양전지와 Interconnect회로의 구성이 I-V특성과 Hot Spot에 미치는 영향 (The effect of I-V characteristic and hot-spot by solar cell and interconnection circuit in PV module)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.241-246
    • /
    • 2008
  • In this paper, we analyze the I-V curve and hot-spot phenomenon caused by solar cells' serial and parallel connected circuit. The mis-match loss of parallel interconnection with low Isc string decrease lower than serially interconnected one and temperature caused by hot-spot does. Also, mis-match loss of parallel interconnection with low Voc string increase more than serially interconnected one. The string having low Voc happened hot-spot phenomenon when open circuit. The bad solar cell in string gives revere bias to good solar cell and make hot-spot phenomenon. If we consider the mis-match loss, when designing PV module and array. the efficiency of PV system might increase.

  • PDF

A Simple Real-Time DMPPT Algorithm for PV Systems Operating under Mismatch Conditions

  • Aniruddha, Kamath M.;Jayanta, Biswas;Anjana, K.G.;Mukti, Barai
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.826-840
    • /
    • 2018
  • This paper presents a distributed maximum power point tracking (DMPPT) algorithm based on the reference voltage perturbation (RVP) method for the PV modules of a series PV string. The proposed RVP-DMPPT algorithm is developed to accurately track the maximum power point (MPP) for each PV module operating under all atmospheric conditions with a reduced hardware overhead. To study the influence of parameters such as the controller reference voltage ($V_{ref}$) and PV current ($I_{pv}$) on the PV string voltage, a small signal model of a unidirectional differential power processing (DPP) based PV-Bus architecture is developed. The steady state and dynamic performances of the proposed RVP DMPPT algorithm and small signal model of the unidirectional DPP based PV-Bus architecture are demonstrated with simulations and experimental results. The accuracy of the RVP DMPPT algorithm is demonstrated by obtaining a tracking efficiency of 99.4% from the experiment.

결정질 PV 모듈의 string 구성에 따른 바이패스 다이오드 동작 특성 (The Characteristic of the Performance of the Bypass Diode with Composition Change of the String in Si-PV Module)

  • 지양근;공지현;강기환;유권종;안형근;한득영
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2212-2217
    • /
    • 2010
  • Previous studies have been focused on the voltage of Bypass diode and Isc(Short Circuit Current) of the influenced solar cell. The Bypass diode starts working when it gets the reverse applied voltage. Previous studies have only concentrated on Isc of the influenced solar cell and Imp of PV module to explain the bypassing performance. PV module is usually working together with inverter having MPPT(Maximum Power Point Tracking) function for best performance. bypassing point is regulated by MPPT function of inverter. In this paper, simulation results of Bypass diode in PV module have been analyzed to represent the relationship of the bypassing point with the composition of PV module. From the results, the more cells are connected with each string, the earlier bypassing performance happens under the fixed number of strings. As diode groups increase or irradiation decreases, the bypassing performance starts fast.

국내 태양광발전용 마이크로 인버터 기술기준에 관한 연구 (A Study on the Technical Standard of Micro-Inverter for Domestic Photovoltaic Power Generation)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.175-180
    • /
    • 2019
  • 스트링 인버터의 정격전력이 낮은 단점을 보완하기 위하여 전력변환장치(PCS: Power Conditioning System)를 마이크로 인버터를 사용하여 기존 PCS와 비교하여 마이크로 인버터의 필요성과 향후의 발전 방향을 고찰하고자 한다. 현재 가정용 태양광발전 시스템에서는 스트링 인버터를 사용해 왔으며 유럽을 시작으로 스트링 인버터의 단점을 보완할 수 있는 마이크로 인버터(PV-MIC)의 연구 및 보급률이 확장 되고 있는 실정이다. 그러나 국내 태양광인버터 업계에서는 태양광발전용 마이크로 인버터(PV-MIC)에 대한 정확한 기술기준 및 시험 측정 장비 및 관련 시험방법 부재가 제품 개발에 걸림돌이 되고 있다. 따라서 본 논문에서는 마이크로 인버터(PV-MIC)의 특성을 고려하여 시험측정 장비 및 관련 기술기준 연구를 통해 선진기술 변화에 뒤쳐지지 않도록 경쟁력을 갖출 수 있는데 목적을 둔다.