• Title/Summary/Keyword: PSC beam

Search Result 133, Processing Time 0.025 seconds

Effect of prestressing on the natural frequency of PSC bridges

  • Shin, Soobong;Kim, Yuhee;Lee, Hokyoung
    • Computers and Concrete
    • /
    • v.17 no.2
    • /
    • pp.241-253
    • /
    • 2016
  • Depending on the researcher, the effect of prestressing on the natural frequency of a PSC (prestressed concrete) structure appear to have been interpreted differently. Most laboratory tests on PSC beams available showed that the natural frequency is increased appreciably by prestressing. On the other hand, some other references based on field experience argued that the dynamic response of a PSC structure does not change regardless of the prestressing applied. Therefore, the deduced conclusions are inconsistent. Because an experiment with and without prestressing is a difficult task on a full size PSC bridge, the change in natural frequency of a PSC bridge due to prestressing may not be examined through field measurements. The study examined analytically the effects of prestressing on the natural frequency of PSC bridges. A finite element program for an undamped dynamic motion of a beam-tendon system was developed with additional geometric stiffness. The analytical results confirm that a key parameter in changing the natural frequency due to prestressing is the relative ratio of prestressing to the total weight of the structure rather than the prestressing itself.

A Study on Strengthening of PSC Beam by Fatigue Experiment (피로 실험에 의한 PSC 부재의 성능개선기법에 관한 연구)

  • Kim, Hyun-Ho;Song, Jae-Pil;Kim, Ki-Bong;Chung, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.1
    • /
    • pp.165-172
    • /
    • 2003
  • The fatigue problem of Prestressed Concrete(PSC) bridges are more serious than the other type of concrete bridges, because the cross sectional area and self weight of PSC bridges are smaller. The endurance of strengthening methods for PSC bridges are tested in this study. Glass fiber sheeting and external post-tensioning methods were applied. 1/5 scale PSC beams were made for fatigue test, same as static test. The range of repeated load is from 10% to 80% of yielding load with sine curve. The experimental results show that the failure cycle of strengthened members are increased compare to non-strengthened members. The members strengthened with glass fiber show better enhancement in fatigue problem than the members strengthened with external post-tensioning method, though the adhesion of glass fiber and concrete is failed, as increase of crack. With these experimental results, it can be said that the strengthening methods used in this study are efficient at extending the life time of aged PSC bridges.

Verification of experimental test for PSC-Steel-PSC hybrid beam using nonlinear FEM analysis (비선형 FEM 해석을 이용한 PSC-Steel-PSC 혼합구조 보의 휨 실험 검증)

  • Kim, Sang-Hyo;Won, Jung-Hun;Park, Se-Jun;Lee, Chan-Gu
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.517-520
    • /
    • 2009
  • 본 연구에서는 비선형 FEM 해석을 이용하여 PSC(Prestressed concrete)와 강으로 구성된 혼합구조 보의 휨 실험을 검증하였다. 혼합구조 보의 거동에 가장 큰 영향을 미치는 연결부는 Perfobond rib로 구성된 경우와 스터드로 구성된 경우를 고려하였다. 이종 재료가 접하는 경계면의 상호 작용에 대해 완전합성과 부분합성인 경우를 고려하여 혼합구조 보의 비선형 해석을 수행한 후 해석 결과와 실험 결과를 비교하였다. 하중-처짐관계, 파괴 형상 등의 해석 결과를 실험 결과와 비교한 결과, 부분합성을 고려한 모형이 실험 결과와 유사한 거동을 보였으며 또한 Perfobond rib를 갖는 실험체가 스터드를 갖는 실험체보다 해석 결과와 비교 시 안전측의 결과를 나타냈다.

  • PDF

Nondestructive Damage Detection in PSC Beams : Frequency-Based Method Versus Mode-Shape-Based Method (고유진동수 이용 손상추정법과 모드형상 이용 손상추정법에 의한 PSC 보의 비파괴 손상검색)

  • 김정태;류연선;조현만
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.43-58
    • /
    • 2002
  • A methodology to nondestructively locate and estimate size of damage in beam-type structures using a few natural frequencies or a few mode shapes is presented. A damage-localization algorithm to locate damage from changes in natural frequencies and a damage-sizing algorithm to estimate crack-size from natural frequency perturbation are outlined. A damage index algorithm to localize and estimate severity of damage from monitoring changes in mode shapes is outlined. The frequency-based method and the mode-shape-based method are evaluated for several damage scenarios by locating and sizing damage in PS concrete beams lot which a few natural frequencies and mode shapes are generated from finite element models. The result of the analyses indicates that the two methods correctly localize and closely estimate the size of the crack simulated in the test beam.

Identification of prestress-loss in PSC beams using modal information

  • Kim, Jeong-Tae;Yun, Chung-Bang;Ryu, Yeon-Sun;Cho, Hyun-Man
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.467-482
    • /
    • 2004
  • One of the uncertain damage parameters to jeopardize the safety of existing PSC bridges is the loss of the prestress force. A substantial prestress-loss can lead to severe problems in the serviceability and safety of the PSC bridges. In this paper, a nondestructive method to detect prestress-loss in beam-type PSC bridges using a few natural frequencies is presented. An analytical model is formulated to estimate changes in natural frequencies of the PSC bridges under various prestress forces. Also, an inverse-solution algorithm is proposed to detect the prestress-loss by measuring the changes in natural frequencies. The feasibility of the proposed approach is evaluated using PSC beams for which a few natural frequencies were experimentally measured for a set of prestress-loss cases. Numerical models of two-span continuous PSC beams are also examined to verify that the proposed algorithm works on more complicated cases.

The Effect of Design Parameter on the Beam Depth of IPC Girder Continuous Bridge (교량설계 변수가 IPC 거더 연속교의 형고에 미치는 영향)

  • 한만엽;김보형;김상완
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.125-130
    • /
    • 2001
  • A existing design method of PSC girder bridges, according to total service loads, stress required tendon force at a time. Because this design method increases beam depth, design of long span is difficult. However, As UC girder stressing at difficult loading stages reduces sectional depth of PSC girder, both design and operation of long span bridges is possible. so, this study analyzes the effect of design parameter (Girder Strength, Girder Spacing, Span Length, Joint Strength) on the beam depth of IPC girder continuous bridges, and shows sectional depth of UC girder for design of long span bridges. According to analysis, when a continuous bridges of same length span is at strength of joint over strength of girder of 600kg/$cm^{2}$, a change of beam depth is observed and when a continuous bridges of different span length is at strength of joint below strength of girder of 600kg/$cm^{2}$, a change of beam depth is observed. In two case, a change of beam depth is mostly observed over strength of girder of 350kg/$cm^{2}$ according to analysis of deflection data, a continuous bridges of IPC girder is nearly satisfied.

  • PDF

An Experimental Study to Determine the Effective Prestress force of PSC Beam (PSC 부재의 유효 프리스트레스력 평가를 위한 실험적 연구)

  • Chung, Chul-Hun;Park, Jae-Gyun;Kim, Kwang-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.21-29
    • /
    • 2008
  • To evaluate the structural integrity of the NPP containment building more rigorously, the effective prestress, which is one of the most affecting elements, needs to be estimated exactly. This paper presents the results of an experimental study to determine the effective prestress force in prestressed concrete beams. It is possible to improve the effective prestress measuring method by test beam, which is being applied for the investigation of the nuclear power plant in operation. If experimentally evaluated Lift-Off method in this study can be coupled with test beam test currently being used in in-service nuclear power plant, it is possible to measure prestress loss of the tendon and the level of the effective prestress load.

Evaluation of Velocity and Source Locations of Acoustic Signals in PSC Beam (AE기법을 이용한 PSC보의 음파속도 및 음원위치 산정)

  • Youn, Seok-Goo;Kim, Eun-Keum;Choi, Min-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.330-333
    • /
    • 2006
  • In this paper experimental tests were performed to evaluate velocities of the acoustic waves through prestressed concrete beam and source locations using AE technique. Seven AE sensors are mounted on the surface of 5m length test beam with equal spacing and using Schmidt Hammer AE events are made 18 locations. The velocities of AE signals are evaluated using the time differences of arrival times and the distances between the AE source loactions and the AE sensor locations. In addition, using the Least Square Method, the AE source locations are re-evaluated reversely using both of the arrival times and the velocities of AE signals. Test results show the average velocity of the AE signals is about 4,000m/sec and the velocity decreased with the increase of the trevalling times due to the effect of attenuation. Based on the estimation of the source locations, it is observed that the accuracy of source location is increased when the velocity of each AE sensor used rather than the average velocity.

  • PDF

The Analysis of The Behavior of PSC Girder by Cross Beam (PSC 거더의 가로보 영향과 거동해석)

  • You, Jung-Doo;Park, Tae-Hyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.169-170
    • /
    • 2010
  • This paper mainly investigates the adequate number of cross beams at the IPSC(Incrementally PreStressed Concrete) girder bridge. The length of span was fixed to 50m and FE model was analyzed by using the ABAQUS program. The models for the numerical tests result in the cases whose number of cross beam are respectively 2, 3, 4, and 5. All of the results of proposed numerical tests satisfy the current specifications. Also, based on the results, we can determine the optimal number of cross beam for more economic design and improvement in constructability.

  • PDF

A Study of the Tendon Profile of a PSC Continuous Beam Able to Resist the Negative Bending Moment of Continuous Intergirders (거더 연속부의 부모멘트 제어에 효과적인 PSC 연속보의 텐던 배치에 관한 연구)

  • Kim, Eui Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • The problems associated with the continuous method of a domestically improved prestressed concrete (PSC) girder and the bending moment of a continuous tendon were studied. Based on the results, a continuous tendon model was proposed that can resist the negative bending moment of an intergirder. This model lowers the anchorage of the continuous tendon as far as possible under the girder, and extends the tendon section arranged under the girder. This method reduces the PS's bending moment in the middle of the span, but maximizes it in the intergirder. This continuous tendon model can offer a suitable method for continuity before manufacturing a composite, which requires a higher design bending moment in the intergirder than in the middle of the span.