• Title/Summary/Keyword: PSA performance

Search Result 100, Processing Time 0.023 seconds

An algorithm for evaluating time-related human reliability using instrumentation cues and procedure cues

  • Kim, Yochan;Kim, Jaewhan;Park, Jinkyun;Choi, Sun Yeong;Kim, Seunghwan;Jung, Wondea;Kim, Hee Eun;Shin, Seung Ki
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.368-375
    • /
    • 2021
  • The performance time of human operators has been recognized as a key aspect of human reliability in socio-complex systems, including nuclear industries. Because of the importance of the time factor, most existing human reliability assessment methods provide ways to quantify human error probabilities (HEPs) that are associated with the performance time. To quantify such kinds of HEPs, it is crucial to rationally predict the length of time required and time available and compare them. However, there have not been detailed guidelines that identify the critical cue presentation time or initial time of human performance, which is important to calculate the time information. In this paper, we introduce a time-related HEP calculation technique with a decision algorithm that determines the critical cue and its timing. The calculation process is presented with the application examples. It is expected that the proposed algorithm will reduce the variability in the time-related reliability assessment and strengthen the scientific evidence of the assessment process. The detailed description is provided in the technical report KAERI/TR-7607/2019.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Development of a Fire Human Reliability Analysis Procedure for Full Power Operation of the Korean Nuclear Power Plants (국내 전출력 원전 적용 화재 인간신뢰도분석 절차 개발)

  • Choi, Sun Yeong;Kang, Dae Il
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.87-96
    • /
    • 2020
  • The purpose of this paper is to develop a fire HRA (Human Reliability Analysis) procedure for full power operation of domestic NPPs (Nuclear Power Plants). For the development of fire HRA procedure, the recent research results of NUREG-1921 in an effort to meet the requirements of the ASME/ANS PRA Standard were reviewed. The K-HRA method, a standard method for HRA of a domestic level 1 PSA (Probabilistic Safety Assessment) and fire related procedures in domestic NPPs were reviewed. Based on the review, a procedure for the fire HRA required for a domestic fire PSA based on the K-HRA method was developed. To this end, HRA issues such as new operator actions required in the event of a fire and complexity of fire situations were considered. Based on the four kinds of HFE (Human Failure Event) developed for a fire HRA in this research, a qualitative analysis such as feasibility evaluation was suggested. And also a quantitative analysis process which consists of screening analysis and detailed analysis was proposed. For the qualitative analysis, a screening analysis by NUREG-1921 was used. In this research, the screening criteria for the screening analysis was modified to reduce vague description and to reflect recent experimental results. For a detailed analysis, the K-HRA method and scoping analysis by NUREG-1921 were adopted. To apply K-HRA to fire HRA for quantification, efforts to modify PSFs (Performance Shaping Factors) of K-HRA to reflect fire situation and effects were made. For example, an absence of STA (Shift Technical Advisor) to command a fire brigade at a fire area is considered and the absence time should be reflected for a HEP (Human Error Probability) quantification. Based on the fire HRA procedure developed in this paper, a case study for HEP quantification such as a screening analysis and detailed analysis with the modified K-HRA was performed. It is expected that the HRA procedure suggested in this paper will be utilized for fire PSA for domestic NPPs as it is the first attempt to establish an HRA process considering fire effects.

The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM) (인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가)

  • Choi, Sung Hee;Shin, Sun Young;Lim, So Hee;Hong, Mee Kyung;Noh, Gyeong Woon;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.158-162
    • /
    • 2014
  • Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

  • PDF

Usable Capacity for CO2 capture and storage in MOFs (금속 유기 골격체를 활용한 사용 가능한(Usable capacity) 이산화탄소 포집 연구)

  • Park, Seoha;Oh, Hyunchul;Jang, Haenam
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.80-85
    • /
    • 2018
  • Usable capacity is one of the most important parameters for evaluating the performance of an adsorbent for $CO_2$ capture from flue gas streams. In the pressure swing adsorption (PSA) process, the usable capacity is calculated as the difference between the quantity adsorbed in flue gas at high pressure (ca. 20 bar) and the quantity adsorbed at lower purge pressure (ca. 2 bar). In this paper, two stereo-types of metal-organic framework (MOF) were evaluated as an promising adsorbent for $CO_2$ capture: flexible structured MOF (MIL-53) and MOF possessing strong binding sites (MOF-74). The results showed that a total $CO_2$ capture capacity is strongly related to the specific surface area and heat of adsorption, revealing high uptake in MOF-74. However, the usable capacity was more pronounced in MIL-53 due to a structural transition.

Effect of Functional Monomers on Pressure-sensitive Adhesives of Acrylic Emulsion (아크릴에멀젼 점착제에 대한 기능성 단량체의 영향)

  • Choi, Yong-Hae;Kang, Jin-Kyu;Lee, Won-Ki
    • Journal of Adhesion and Interface
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • The waterborne acrylic pressure-sensitive adhesive in the basis of butylacylate (BA) and 2-Ethylhexylacrylate (2-EHA) was synthesized and the methyl methacrylate (MMA) have been used to give the rigidity perfroamce. The polymreric latex was synthesized using butyl acrylate (BA), 2-ethylhexyl acrylate (EHA), methyl methacrylate (MMA) and each 1, 2, 3% of various functional monomers. The dimethyl-2-imidazlidon acrylate and 2-acrylamido-2-methyl-1-propanesulfonate was used in order to increase the wetting properties of acrylic emulsion. To study of properties of functional monomer, The polymreric latex was synthesized various functional monomers each 1, 2, 3%. The 2-acrylamido-2-methyl-1-propanesulfonate showed the best properties. Latex with acrylic acid and dimethyl-2-imidazlidon acrylate had good peel strength, holding power, but it showed that they didn't separate from adhered cleanly by weak cohesion strength. The adhesion performance was increased by increasing amount of 2-acrylamido-2-methyl-1-propanesulfonate however latexes with upper 7% 2-acrylamido-2-methyl-1-propanesulfonate showed that the properties of PSA decreased.

  • PDF

Development of Shading Tape for Manufacturing of Touch Panel Display with High Screen-to-Body Ratio (기기 면적 대비 높은 화면 비율을 갖는 터치 패널 디스플레이 제조를 위한 차광 테이프의 개발)

  • Kim, Ki-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.75-81
    • /
    • 2017
  • The design trend of information technology is quickly changed with the times. The design trend of information display is a bezel-less display, recently. The bezel-less display or edge-less display is a new trend of mobile phone display. In this study, the shading tape was manufactured for assembling process of touch panel display with the high screen-to-body ratio so-called bezel-less display. The shading tape was fabricated on PET film with the UV curable acrylic pressure sensitive adhesive(PSA) by roll-to-roll process. The UV curable PSA was synthesized with the eco-friendly toluene-less manufacturing method. The adhesive power of manufactured shading tape was investigated by motorized tensile testing machine. The thixotropic, maintaining property of cutting shape, was characterized by field emission scanning electron microscope. As results, the shading tape exhibits high adhesive power and good thixotropic performance suitable for assembly process of touch panel display. The functional shading tape will be expected to improve productivity of assembly process of touch panel display.

Development of the Monitoring and Diagnosis Technique on Emergency Diesel Generator System (비상디젤발전기계통 상태감시 및 고장진단기술 개발)

  • Cho, Kwon-Hae;Rhyu, Keel-Soo;So, Myung-Ok;Park, Jong-Il;Son, Min-Su;Ahn, Jong-Kap;Lee, Yun-Hyung;Jang, Tae-Lin
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.777-782
    • /
    • 2005
  • The importance of emergency diesel generator(EDG) has confirmed in the safety evaluation of PSA and the study on aging of EDG has been progressed actively as a part of the project of nuclear plant aging research in the U.S.A. As the result, the concept of performance evaluation is being transferred from statistical analysis of test results to performance monitoring and trending analysis for monitoring of aging and reliability. Recently, the study related aging characteristic and reliability for EDGS has begun in Korea. Consequently, the efficient performance monitoring based systematic and integrated monitoring and failure diagnostic technology is necessary. In the research, the knowledge basis of monitoring parameters for EDGS is constructed, and the prototype monitoring and diagnosis system applicable to Pielstick EDG is developed.

  • PDF

A Study on the Adsorption Characteristics of Nitrogen and Oxygen on Ion Exchanged Zeolite Adsorbents (이온교환된 제올라이트 흡착제의 질소 및 산소 흡착 특성 연구)

  • Jeong, Heon-Do;Kim, Dong-Sik;Kim, Kweon-Ill
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.123-130
    • /
    • 2005
  • Zeolite X adsorbents with large surface area were prepared for using oxygen PSA adsorbent. Selective adsorption performance of nitrogen on the synthesized zeolite X adsorbent was improved by the cation exchange of adsorbent. The zeolite X which had over $650m^2/g$ surface area was synthesized at the conditions of $SiO_2\;:\;Na_2O\;:\;H_2O\;:\;Al_2O_3$ = 2.5 : 3.5 : 150 : 1 mole ratio, $98^{\circ}C$ temperature and 18 h synthesized time in 50 L reactor. The metal ions Li, Ag, Ca, Br, Sr, etc. were investigated for ion exchange with zeolite X. Ag ion was showed the highest ion exchange rate among these metal ions and all metal ions were exchanged with Na ion at equivalent rate. Compared with the NaX adsorbent, the ion exchanged zeolite X adsorbent remarkably improved its adsorption performance of nitrogen at the conditions of $10{\sim}40^{\circ}C$ temperature and 0~9 atm pressure. At an equilibrium pressure under 0.5 atm, adsorption performance of nitrogen on the ion exchanged zeolite adsorbent increased in the order of Ag > Li > Ca > Sr> Ba > K, whereas at an equilibrium pressure over 1 atm showed in the order of Li > Ag > Ca > Sr > Ba > K. Nitrogen/oxygen separation factor of Li ion exchanged zeolite X adsorbent was 13.023 at the partial pressure of nitrogen/oxygen gas mixture similar to air and $20^{\circ}C$ adsorption temperature.

다결정 실리콘 Self-align에 의한 바이폴라 트랜지스터의 제작

  • Chae, Sang-Hun;Gu, Jin-Geun;Kim, Jae-Ryeon;Lee, Jin-Hyo
    • ETRI Journal
    • /
    • v.7 no.4
    • /
    • pp.11-14
    • /
    • 1985
  • A polysilicon self-aligned bipolar n-p-n transistor structure is described, which can be used in high speed and high packing density LSI circuits The emitter of this transistor is separated less than $0.4\mum$ with base contact by polysilicon self-align technology. Through all the process, the active region of this device is not damaged. therefore a high performance device is obtained. Using the transistor with $3.0\mum$ design rules, a CML ring oscillator has per-gate minimum propagation delay time of 400 ps at 2.7 mW power consumption condition.

  • PDF