• Title/Summary/Keyword: PPG 신호

Search Result 143, Processing Time 0.025 seconds

Analysis of Optimal and Pleasant Driving Condition using Physiological Signals (생리신호 측정을 통한 심리적 적정 운전상태 분석)

  • 김정룡;황민철;박지수;윤상영
    • Science of Emotion and Sensibility
    • /
    • v.7 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • This study has investigated a psychological status of optimal and pleasant driving condition by measuring various physiological signals using SCR(skin conductance response), PPG(peripheral plethysmograph), SKT(skin temperature) and HR(heart rate). The physiological response was measured during various simulated driving conditions. We developed a hardware and algorithm to measure and analyze the physiological response. The physiological signals has reflected the level of driver's tension or relaxation as well as the heart rate. The emotional responses of drivers were also measured and analyzed in this experiment. The result of the study can be used to design a system to enhance the driver's emotional satisfaction as well as to monitor the driver's safety and health condition.

  • PDF

Development of a Photoplethysmographic method using a CMOS image sensor for Smartphone (스마트폰의 CMOS 영상센서를 이용한 광용적맥파 측정방법 개발)

  • Kim, Ho Chul;Jung, Wonsik;Lee, Kwonhee;Nam, Ki Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4021-4030
    • /
    • 2015
  • Pulse wave is the physiological responses through the autonomic nervous system such as ECG. It is relatively convenient because it can measure the signal just by applying a sensor on a finger. So, it can be usefully employed in the field of U-Healthcare. The objects of this study are acquiring the PPG (Photoplethysmography) one of the way of measuring the pulse waves in non-invasive way using the CMOS image sensor on a smartphone camera, developing the portable system judging stressful or not, and confirming the applicability in the field of u-Healthcare. PPG was acquired by using image data from smartphone camera without separate sensors and analyzed. Also, with that image signal data, HRV (Heart Rate Variability) and stress index were offered users by just using smartphone without separate host equipment. In addition, the reliability and accuracy of acquired data were improved by developing additional hardware device. From these experiments, we can confirm that measuring heart rate through the PPG, and the stress index for analysis the stress degree using the image of a smartphone camera are possible. In this study, we used a smartphone camera, not commercialized product or standardized sensor, so it has low resolution than those of using commercialized external sensor. However, despite this disadvantage, it can be usefully employed as the u-Healthcare device because it can obtain the promising data by developing additional external device for improvement reliability of result and optimization algorithm.

Diagnostic Usefulness of Quantitative Sensory Test Comparison with Photoplethysmography (광용적맥파와 정량적 감각검사의 비교를 통한 진단적 유용성)

  • LEE, Sang-Bong;SEO, Jeong-Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.315-322
    • /
    • 2015
  • The purposes of this study were to compare the sensitivities of two tests, QST(quantitative sensory test)and PPG(photoplethysmography) in normal adults. We evaluated the sensory thresholds of QST and PPG and diabetes mellitus test in 17 normal adults. The finding of this study can be summarized as follow :The diagnostic sensitivities of QST was similar to PPG. There is a direct correlation between the amount of Blood sugar and parasympathetic nerve in ANS. Concluded that the QST might be complement to NCS for early of diabetic polyneuropathy. A new diagnostic approach, QST was introduced and exploited for diagnosis. This study provides support for PPG performed a ANS analysis.

The Plug-in Module for Simultaneous Monitoring of Multi Bio-signal in Wearable Devices (착용형 단말에서 다수 생체신호의 동시 측정을 가능하게 하는 플러그인 모듈)

  • Choi, Moon Sik;Choi, Dong Jin;Kang, Soon Ju
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.4
    • /
    • pp.195-200
    • /
    • 2016
  • With development of wearable devices, there is an increased interest in bio-signal monitoring techniques that can measure the user's health condition. However, embedding several bio-signal sensors in one wearable device has some inherent problems in terms of limited resources such as its size. Furthermore, such problem also arise when new bio-signal sensors are added. In this paper, we introduced the Bio-Cradle, which is a Plug-in module that can transfer the biological signals in real time from the accelerometer, ECG, or PPG sensor to other wearable devices at the request from the user of wearable devices. When the Bio-Cradle plugged in to the other device, it can transfer several synchronized bio-signals regardless of the type of device.

Implementation of the Multi-channel Vital Signal Monitoring System for Home Healthcare (홈 헬스케어를 위한 다채널 생체신호 모니터링 시스템 구현)

  • Youn, Jeong-Yun;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.3
    • /
    • pp.197-202
    • /
    • 2010
  • In this paper, multi-channel vital signal monitoring system was implemented for home healthcare. The system able to measure vital signal for example ECG, PPG and temperature simultaneously at patients’ home. The vital signal is an essential parameter for healthcare application and can be easily extracted from patients. The implemented system consist of sensor parts for signal extraction, signal amplifier and filter for analog circuit, analog signal to digital conversion for controlling devices and lastly the monitoring program. The system able to transmit vital signals using Bluetooth wireless communications to personal computer or home server. And the tele-monitoring system able to display real-time signals using web monitoring program. In medical application, the vital signal parameter able to stored and saved in the web server for further medical analysis. This system opens up the possibilities of ubiquitous healthcare where further implementation can be easily done.

Design of A Portable Device for Measuring Heart Rate Using Harmonic Signal and Adaptive Filter (하모닉 신호와 적응 필터를 이용한 휴대형 심박수 측정 장치 설계)

  • Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.723-728
    • /
    • 2010
  • This study proposed a design of a portable device for measuring heart rate using photoplethysmograph signal to minimize load of a nurse increased from insufficiency of an internal hospital nurse, and algorithm to measure reliable heart rate in PPG signals despite the existence of patient's motion artifacts. The proposed method for measuring heart rate is the method to minimize the motion interference by using the adaptive filter based on harmonic characteristic of PPG signal. To evaluate the performances of the a portable device implemented by the proposed method, we used several motion artifacts including finger and wrist movements; we then compared out results with the performance of the moving average filter. In this results, the proposed method showed a better performance than that of the moving average filter. Therefore, when nurses use the a portable device for measuring heart rate proposed in this study, it will enable to improve nurse work and to measure the reliable heart rate.

An analysis of correlation between EEG signal and HRV during attentional status with children under 15 years (15세 미만 아동을 대상으로 한 집중상태에서 EEG 신호와 HRV의 상관관계 분석)

  • Choi, Woo-Jin;Lee, Chug-Ki;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.269-278
    • /
    • 2011
  • This paper illustrates the inter-relationship between the theta/alpha ratio of the EEG signal and multiple HRV related parameters associated with the cardiovascular system response during event-related stimuli. Both EEG and PPG signals were simultaneously recorded in 21 healthy subjects. All subjects had their attention focused on the CNT program for nine minutes. Time-frequency analysis was applied to the EEG and PPG signals. The theta/alpha ratio was extracted from the EEG results, and the HRV features, including beat interval(1), SDNN(2), RMSSD(3), NN50(4), LF(5), HF(6), and LFIHF(7), were extracted from the PPG. Through multiple linear regression, the relationship ($R^2$) between the multiple combined features and the theta/alpha rhythm was identified. As a result, the combinations of $R^2$($R^2=0.253$; seven dimensions) and the theta/alpha ratio indicated a higher inter-relationship value than those of other combinations. The combinations of features that were greater than three dimensions, based on {SDNN(2), HF(6)}, generally showed higher $R^2$ value. We demonstrate that the high dimensional combinations had a higher correlation than did the low dimensional combinations.

  • PDF

Prediction pulse transit time using electrocardiogram (심전도를 사용한 맥파전달시간차 예측)

  • Jeong, ChangGil;Yoo, JaeChern
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.05a
    • /
    • pp.514-516
    • /
    • 2021
  • 본 연구는 심혈관계 질환 진단에 주고 사용되는 PTT 를 계산할 때 필요한 PPG 신호가 없을 경우 ECG 신호만을 사용하여 PTT 값을 예측하는 방법을 제안한다. MIMIC-I 데이터셋에서 2 채널 심전도 데이터와 광전용적맥파 데이터를 확보하여 제안하는 방법을 적용하였을 때, RMSE 0.07116 으로 예측하였다. 본 연구는 향후 단일 생체신호만 측정할 수 있는 제한된 상황에서 대안으로 활용될 수 있을 것이다.

A Study on the Effects of Ambient Light on the Reflective PPG Measurement Device using Infrared (적외선을 사용한 반사형 PPG 측정 장치에서의 주변광의 영향에 대한 연구)

  • Namsub Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.406-412
    • /
    • 2023
  • In this paper, we studied the effect of noise caused by ambient light on a reflective PPG measurement device using infrared light. Noise caused by ambient light was examined by dividing it into general situations and special situations. In the general situation, noise due to changes in time and ambient light sources was randomly observed, and in the special situation, a halogen lamp was used to observe the effect of noise variations. In the experiment, PPG signals were measured and data acquired in real-time depending on each situation, and the measured data was analyzed in the time domain and frequency domain. First, through a general situation experiments, it was visually observed that noise increases with the brightness of ambient light, and through frequency analysis, it was observed that the noise sources were white noise, power line noise, and internal noise of the circuit. Futhermore, using a halogen lamp, we experimented with the change in noise depending on the change in distance from the ambient light and calculated the SNR. As a result of the experiment, an SNR of 3.2 dB was shown at a distance of 50 cm with an irradiance of 278.3 W/m2. It was observed that normal measurement was difficult at SNRs below that, and an irradiance of 27.7 W/m2 was obtained. It showed a value of 18.2 dB at a distance of 2 m, and it was observed that normal PPG measurement was possible through a filter at values above that.