• Title/Summary/Keyword: POOL

Search Result 2,559, Processing Time 0.029 seconds

Analysis of Pool Price and LOLP from Capacity Margin in Competitive market (설비예비율에 따른 공급지장과 경쟁시장에서 Pool가격의 영향)

  • Kim, C.S.;Pack, Y.S.;Rhee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.512-514
    • /
    • 2001
  • Recently, Korea's electric industry is in the midst of a period of profound changes in the structure and function, including the introduction of market competition in the generation sector. Korea is in the early stages of market competition, so the market price is chosen by generation costs but will be chosen by bids in future. Therefore, the profits of generators is determined by market pool price and the prospects of pool price are very important for new capacity investment determination of generators and IPPs. This study analyzes hourly marginal costs and LOLP considering basic generation mix and characteristics, develops the relationship of pool price using the above in competition market, and proposes basic direction for profits variation and supply-demand analysis in the electric market in future.

  • PDF

Flow Analysis of Two-Dimensional Floating Body with Moon Pool Using a Numerical Wave Tank (수치 파동 수조를 이용한 부유체의 문풀 (Moon Pool) 유동해석)

  • Koo, Weon-Cheol;Lee, Kyoung-Rok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.2
    • /
    • pp.107-112
    • /
    • 2011
  • The aim of this study is to analyze the hydrodynamic properties of a 2D floating body with moon pool using a 2D fully nonlinear Numerical Wave Tank(NWT). This NWT was developed based on the Boundary Element Method(BEM) with potential theory and fully nonlinear free surface boundary conditions. Free surface elevations in the moon pool were calculated in the time domain for various frequencies of forced body motions. The added-mass and damping coefficients of the heaving body were also obtained. The present numerical results were compared with the analytic and experimental results and their accuracy was verified.

Preliminary analyses on decontamination factors during pool scrubbing with bubble size distributions obtained from EPRI experiments

  • Lee, Yoonhee;Cho, Yong Jin;Ryu, Inchul
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.509-521
    • /
    • 2021
  • In this paper, from a review of the size distribution of the bubbles during pool scrubbing obtained from experiments by EPRI, we apply the bubble size distributions to analyses on the decontamination factors of pool scrubbing via I-COSTA (In-Containment Source Term Analysis). We perform sensitivity studies of the bubble size on the various mechanisms of deposition of aerosol particles in pool scrubbing. We also perform sensitivity studies on the size distributions of the bubbles depending on the diameters at the nozzle exit, the molecular weights of non-condensable gases in the carrier gases, and the steam fractions of the carrier gases. We then perform analyses of LACE-ESPANA experiments and compare the numerical ~ results to those from SPARC-90 and experimental results in order to show the effect of the bubble size distributions.

Analysis of Natural Convection Heat Transfer and Solidification of a Two-Layered Pool (2층으로 성층화된 풀 내에서의 자연대류 열전달과 고화현상에 대한 연구)

  • Kim J.;Kang K. S.;Kim S. B.;Kim H. D.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • The natural convection heat transfer and solidification in a stratified pool are studied. The flow and heat transfer characteristics in a heat generating pool are compared between single-layered and double-layered pools. And local Nusselt number distributions on outer walls are obtained to consider thermal loads on a vessel wall. The cooling and solidification of Al₂O₃/Fe melt in a hemispherical vessel are simulated to study the mechanism of heat transfer and temperature distribution. A unstructured mesh is chosen for this study because of the non-orthogonality originated from the boundaries of double-layered pool. Interface between the layers is modeled to be fixed. With this assumption mass flux across the interface is neglected, but shear force and heat flux are considered by boundary conditions. The colocated cell-centered finite volume method is used with the Rhie-Chow interpolation to compute cell face velocity. To prevent non-physical solutions near walls in case body force is large the wall pressure is extrapolated by the way to include body force. The numerical solutions calculated by current method show that averaged downward heat flux of the double-layered pool increases compared to single-layered pool and maximum temperature occurs right below the interface of the layers.

  • PDF

Extraction of Watershed Information using GIS and Diurnal Flow Change in the Rapids and Pool by the Nature-Friendly River Work (GIS를 이용한 유역정보 추출 및 여울과 소의 치수적 복원을 위한 일중 수치해석)

  • Kang, Sang-Hyeok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.517-522
    • /
    • 2010
  • The riffle and pool play an important role for composing river front, but very little information was used for river restoration considering flood control. In this paper extensive field investigation was carried out to estimate hydraulic processes in the pool. Furthermore diurnal stratification model was developed and applied to assess flow change in pool. The physical mechanism of water flow including diurnal processes was well simulated, the results show that diurnal variation of water flow in the pool about 2 m depth is governed by the level of mixing due to density flow. These effort will be useful to guide field data collection work and to understand primary production.

On the Distribution of Water Temperature in the Warm Water Pool. -On the Wudu Warm Water Pool- (온수지에서의 수온분포에 관한 연구 -우두온수지를 중심으로-)

  • 연규석;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.121-126
    • /
    • 1979
  • The objective of this study was to grasp the condition of the distribution of water temperature in the warm water pool, and these observations were performed in Wudu warm water pool located at Wodu-Dong in Chuncheon. The results summarized in this study are as follows; 1. The horizontal distribution charts of water temperature at each depth of points were shown as Fig. 3, Fig. 4, and Fig. 5, respectively. In consequence of the observation, the condition of warm water was stagnant in the coner of warm water pool. As the result, it was found out that stagnant condition was the heaviest at water surface (depth; 0.05m), more heavier at middle depth (depth; 0.55m) and some heavy at bottom of the pool (depth; 1.10m). 2. The vertical water temperature change was shown as Fig. 6, and the mean water temperature of water surface (depth;0.05m) was higher about $2.2{\sim}3.3^{\circ}C$ than bottom water temperature. 3. Therefore, it was required to device such structures as form of broad cannels or overflow diversion weirs to mingle with top and bottom water.

  • PDF

Status Analysis of Children's Swimming Pool in Korea

  • SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.4 no.3
    • /
    • pp.23-28
    • /
    • 2020
  • Purpose: This study sought to explore current status of children's swimming pool in Korea and to generate insights regarding safety management of children's swimming pool. Research design, data, and methodology: The study reviewed literatures including documents of Ministry of Culture, Sports and Tourism and sport facility-related articles. Furthermore, the study collected additional statistics via search engines. Results: First, numbers of swimming pools have been dramatically increased since 2016 and Korea experienced an increase of 37% from 2010 to 2019. Of the 611 indoor swimming pools, most swimming pools are located in Gyeonggi province with 27.7% (n=169). Seoul and Gyeonggi-do have the highest proportion of swimming pools in Korea. Second, in types of swimming pools, 47.6%(n=291) was children's swimming pool which is the highest proportion in the nation. Children's swimming pools are also mostly located in Seoul and Gyeonggi province with 57%. Third, of 372 profit swimming pools, children's pools show the highest number with 78%(n=291). Conclusions: Children's swimming pools are picking up faster than the other types of swimming pool. Yet, safety-related studies are still lack. This provides motivations to produce managerial insights from academia and business sectors. Moreover, more studies of legal issues should be conducted. Implications were discussed.

Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire (분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Kim, Ho-Young;Oh, Sang-Youp;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire (미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Oh, Sang-Youp;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

Combustion Characteristics of Pool and Whirl Fire on Methanol by Height of Fire Source using the Small Scale (화점높이 변화에 따른 메탄올의 소규모 Pool 및 Whirl Fire의 연소특성)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-78
    • /
    • 2012
  • This study is intended to understand flame behavior of pool and whirl fire by height of fire source. Liquid fuel was methanol which is used in many studies for pool and whirl fire. Size of vessel was $100{\times}100{\times}50$ and the vessel was made by stainless steel. Combustion time, mass loss rate, flame temperature, flame height and air entrainment rate from the outside to flame were measured, and flame behavior was visualized with video camera. Based on the experiment, it was found that combustion characteristics by height of fire source got a more effect on whirl fire than pool fire.