Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 - (현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 -)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

Availability of Toxicologic Screening Tests in the Emergency Department (응급센터에서 시행하는 약물선별현장검사의 유용성)

  • Um, In-Kyung;Park, Jong-Su;Han, Kap-Su;Cho, Han-Jin;Choi, Sung-Hyuck;Lee, Sung-Woo;Hong, Yun-Sik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.1
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The role of a point of care test (POCT) is currently becoming important when treating patients and making decisions in the emergency department. It also plays a role for managing patients presenting with drug intoxication. But the availability of the test has not yet been studied in Korea. Therefore, we investigated the utility and the availability of POCT for drug screening used in the emergency department. Methods: This was a retrospective study for those patients with drug intoxication between January 2007 and December 2010 in an urban emergency department. Results: Between the study period, 543 patients were examined with a Triage$^{(R)}$-TOX Drug Screen. Among those, 248 (45.7%) patients showed negative results and 295 (54.3%) patients showed positive results. The sensitivity of the test for benzodiazepine, acetaminophen and tricyclic antidepressants were 85.9%, 100%, 79.2%, respectively. Conclusion: POCT of drug screening in emergency department showed good accuracy especially in patient with benzodiazepine, acetaminophen and tricyclic antidepressant intoxication. Therefore, it can be useful diagnostic tool for the management of intoxicated patients.

  • PDF

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Development of a Smartphone-based Total Bilirubin Measuring System for Screening of Jaundice (황달 선별검사를 위한 스마트폰 기반의 총빌리루빈 측정시스템의 개발)

  • Kim, Won-Jung;Song, Eunji;Rhee, Joowon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.206-210
    • /
    • 2021
  • Hyperbilirubinemia is the most common neonatal disease and is observed in about 80% of newborns worldwide in neonatal period within a week after birth. Untreated infant hyperbilirubinemia may lead to brain damage and even death, so it is very important to diagnose it quickly and accurately. In this study, a total bilirubin measurement system was developed that is portable and easy to use without pre-processing using a commercial smartphone. This system measures using the LED and camera of the smartphone without the need for additional devices, and because a small amount of blood is injected without pre-treatment, anyone can easily measure it in the field. In a comparative study with Cobas c111 results, accuracy meets CLIA guidelines with 94% (17/18) within ±0.4 mg/dL below 3 mg/dL and 98% within ±20% above 3 mg/dL (276/282). This system offers a simple, fast and accurate diagnosis for jaundice in infants and young children in low-resource settings.

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.