One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

An Algorithm for Detecting Residual Quantity of Ringer's Solution for Automatic Replacement (링거 자동 교체를 위한 잔량 검출 알고리즘)

  • Kim, Chang-Wook;Woo, Sang-Hyo;Zia, Mohy Ud Din;Won, Chul-Ho;Hong, Jae-Pyo;Cho, Jin-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 2008
  • Recently, ere are many researches to improve the quality of e medical service such as Point of care (POC). To improve the quality of the medical service, not only good medical device but also more man power is required. Especially, the number of nurses are very few in Korea that is almost the lowest rank compared to OECD countries. If the simple repetition works of the nurse could be removed, it is possible to use the skillful nurse for other works and provide better quality services. There are many simple repetition works which the nurses have to do, such as replacing the ringer's solution. To replace the ringer's solution automatically, it is necessary to detect residual quantity of the ringer's solution. In this paper, image processing is used to detect the residual quantity of ringer's solution, and modified self quotient image (SQI) algorithm is used to strong background lights. After modified SQI algorithm, the simple histogram accumulation is done to find the residual quantity of the ringer's solution. The implemented algorithm could be use to replace the ringer's solution automatically or alarm to the nurses to replace the solution.

  • PDF

Association of chairside salivary aMMP-8 findings with periodontal risk assessment parameters in patients receiving supportive periodontal therapy

  • Schmalz, Gerhard;Kummer, Max Kristian;Kottmann, Tanja;Rinke, Sven;Haak, Rainer;Krause, Felix;Schmidt, Jana;Ziebolz, Dirk
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.251-260
    • /
    • 2018
  • Purpose: The aim of this retrospective cross-sectional study was to evaluate whether salivary findings of active matrix-metalloproteinase 8 (aMMP-8) chairside (point of care; POC) tests were associated with periodontal risk assessment parameters in patients receiving supportive periodontal therapy (SPT). Methods: A total of 125 patients receiving regular SPT were included, and their records were examined. The following inclusion criteria were used: a diagnosis of chronic periodontitis, at least 1 non-surgical periodontal treatment (scaling and root planning) with following regular SPT (minimum once a year), at least 6 remaining teeth, and clinical and aMMP-8 findings that were obtained at the same appointment. In addition to anamnestic factors (e.g., smoking and diabetes), oral hygiene indices (modified sulcus bleeding index [mSBI] and approximal plaque index), periodontal probing depth simultaneously with bleeding on probing, and dental findings (number of decayed, missing, and filled teeth) were recorded. Salivary aMMP-8 levels were tested using a commercial POC test system (Periomarker, Hager & Werken, Duisburg, Germany). Statistical analysis was performed using the t-test, Mann-Whitney U test, Fisher's exact test, and ${\chi}^2$ test, as appropriate (P<0.05). Results: Only the mSBI was significantly associated with positive salivary aMMP-8 findings (aMMP-8 positive: $27.8%{\pm}20.9%$ vs. aMMP-8 negative: $18.0%{\pm}14.5%$; P=0.017). No significant associations were found between aMMP-8 and smoking, diabetes, periodontal parameters, or parameters related to the maintenance interval (P>0.05). Conclusions: Salivary aMMP-8 chairside findings were not associated with common parameters used for periodontal risk assessment in patients receiving SPT. The diagnostic benefit of POC salivary aMMP-8 testing in risk assessment and maintenance interval adjustment during SPT remains unclear.

A Case Study on the Implementation of a Real-time Patient Monitoring System based on Wireless Network (무선 네트워크 기반의 실시간 환자 모니터링 시스템 구축 사례 연구)

  • Choi, Jong-Soo;Kim, Dong-Soo
    • IE interfaces
    • /
    • v.23 no.3
    • /
    • pp.246-256
    • /
    • 2010
  • As wireless and mobile technologies have advanced significantly, lots of large sized healthcare organizations have implemented so called mobile hospital (m-Hospital) which provides a location independent and point of care (POC) clinical environment. Implementation of m-Hospital enhances quality of care because health professionals such as physicians and nurses can use hospital information systems at the very place where patients are located without any delay. This paper presents a real-time patient monitoring system based on wireless network technologies. A general framework for the patient monitoring process is introduced and the architecture and components of the proposed monitoring system is described. The system collects and analyzes biometric signals of in-patients who suffer from cancer. Specifically, it continuously monitors oxygen saturation of patients in bed and alarms health professionals instantly when an abnormal status of the patient is detected. The monitoring system has been used and clinically verified in a university hospital.

Paper Based Point-of-Care Diagnosis for Appropriate Technology (적정기술을 위한 종이기반 현장 진단 기술)

  • Shin, Kwanwoo;Kwon, Oh-Sun
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.46-53
    • /
    • 2019
  • It should be supported by the ease and economic production in terms of appropriate technology to be widely used in the real applying fields. In particular, the diagnosis of diseases is one of the most difficult areas to apply to the developing countries compared to other fields because of the high costs of professional manpower, equipment, and medial reagents. In recent years, paper, which is one of the most common materials around, has been used to fabricate the disease diagnostic chips, particularly without any special facilities or the equipment. These new technologies lead the possibility of using point-of-care testing devices that can be manufactured quickly in the field by lowering the production cost. These paperbased technologies will contribute to solve many of the deadliest medical problems in developing countries and ultimately improve the quality of human life.

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Evaluation of Albumin Creatinine Ratio as an Early Urinary Biomarker for Chronic Kidney Disease in Dogs

  • Hyun-Min Kang;Heyong-Seok Kim;Min-Hee Kang;Jong-Won Kim;Dong-Jae Kang;Woong-Bin Ro;Doo-Won Song;Ga-Won Lee;Hee-Myung Park;Hwi-Yool Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.399-407
    • /
    • 2023
  • Chronic kidney disease (CKD) occurs in more than 15% of the dogs over 10 years of age and causes irreversible renal function deterioration. Therefore, it is important to diagnose CKD early and treat the disease properly. The purpose of this study aimed to to evaluate the clinical utility of urine albumin/creatinine ratio (ACR) using POC (point-of-care) device as an early detection urinary biomarker in CKD dogs and to confirm the correlation between ACR and other known CKD biomarkers. Urine and serum samples were obtained from 50 healthy dogs and 50 dogs with CKD. Serum blood urea nitrogen (BUN), creatinine, and symmetric dimethylarginine (SDMA) concentrations, and urine protein creatinine ratio (UPC) were measured. Urine specific gravity (USG) was evaluated using refractometer, and ACR was measured using an i-SENS A1Care analyzer. The ACR values of dogs with CKD were significantly different from those of healthy dogs (p < 0.001), as with other renal biomarkers. ACR showed significant differences between healthy dogs and dogs with CKD at every IRIS stage (p < 0.005), whereas no significant differences were observed between dogs with CKD IRIS stage I and healthy dogs with UPC. There are significant positive correlation between ACR and BUN (r = 0.611, p < 0.001), creatinine (r = 0.788, p < 0.001), SDMA (r = 0.747, p < 0.001), and UPC (r = 0.784, p < 0.001), and significant negative correlation between ACR and USG (r = -0.700, p < 0.001). In receiver operator characteristic curve analysis, the area under the curve (AUC) was 0.982 (95% CI 0.963-1.000, p < 0.001), with an optimal cut-off value of 64.20 mg/g (94% sensitivity and 94% specificity). Thus, ACR is a useful urinary biomarker for the early diagnosis of proteinuria in CKD and combined use of ACR and other renal biomarkers may be helpful for early diagnosis and prevention of CKD in dogs.

Electrochemical Detection of Uric Acid using Three Osmium Hydrogels (세개의 오스뮴 고분자를 이용한 요산의 전기화학적 측정방법)

  • Jeon, Won-Yong;Choi, Young-Bong
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.2
    • /
    • pp.29-38
    • /
    • 2016
  • Screen printed carbon electrodes (SPCEs) with immobilized osmium-based hydrogel redox polymer, uricase and PEGDGE can be used to apply uric acid electrochemical detecting. The osmium redox complexes were synthesized by the coordinating pyridine group having different functional group at 4-position with osmium compounds. The synthesized poly-osmium hydrogel complexes are described as PAA-PVI-$[Os(dCl-bpy)_2Cl]^{+/2+}$, PAA-PVI-$[Os(dme-bpy)_2Cl]^{+/2+}$, PAA-PVI-$[Os(dmo-bpy)_2Cl]^{+/2+}$. The different concentrations of uric acid were measured by cyclic voltammetry technique using enzyme-immobilized SPCEs. The prepared SPCEs using PAA-PVI-$[Os(dme-bpy)_2Cl]^{+/2+}$ showed no interference from common physiologic interferents such as ascorbic acid (AA) or glucose. The resulting electrical currents at 0.33 V vs. Ag/AgCl displayed a good linear response with uric acid concentrations from 1.0 to 5.0 mM. Therefore, this approach allowed the development of a simple, point of care in the medical field, disposable electrochemical uric acid biosensor.

A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis (LED와 CMOS 이미지 센서 기반 간 기능 분석용 소형 광학장치)

  • Kim, Chul;Lim, Chang-Jin;Nam, Myung-Hyun;Kim, Dong-Sik;Seo, Sung-Kyu;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.270-275
    • /
    • 2012
  • This paper presents a portable and compact optical device which can conveniently be used to perform a functional analysis of human liver function. The proposed system employed red/green LEDs, as a light source, and CMOS image sensor, which is commonly used in cellular phones. With this system, several blood serum samples have been evaluated for liver functional analysis by measuring light absorption level through the blood serum samples depending on aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin concentration. The light absorption through the blood serum samples containing AST, ALT, or total bilirubin can provide their concentrations. The green light absorption is more sensitive to the concentration of AST or ALT, and the red light absorption is more sensitive to the total bilirubuin concentration. Additional calibration steps were performed by using a MATLAB program in order to eliminate the light scattering effects from the extraneous particles existing in each blood serum sample. From the blind test, three standard light intensity curves through each enzyme have been obtained and the enzyme concentration values have been compared to those obtained from a commercially available biochemistry analyzer (Toshiba 200 FR). The average percent difference in the obtained concentrations from two systems for AST, ALT, and total bilirubin concentration came out to be 7.79%, 7.98%. and 7.56%, respectively, with the adjusted coefficient of determination (R2) higher than 0.98. This system can possibly lead to a low-cost and simple system that can be used as a point-of-care (POC) system in a condition without advanced equipments.