• 제목/요약/키워드: PM10 Air Monitoring

검색결과 304건 처리시간 0.021초

비교 측정을 통한 PM-10 질량농도의 오차 분석 (Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study)

  • 정창훈;조용성;황승만;정용국;유재천;신동석
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

대기오염측정망 정도관리의 문제점과 개선방향 (Problems and Improvements in the Quality Control of the Air Monitoring Network)

  • 김덕승;박정호
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가 (Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station)

  • 임봉빈;이규성;김주인;홍현수;김장원;조경호;정을규;김인규;안연순
    • 한국대기환경학회지
    • /
    • 제30권3호
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

기단 역궤적분석에 의한 경주시 대기오염물질의 농도 변화 (Variation of Concentration of Air Pollutants with Air Mass Back-Trajectory Analysis in Gyeongju)

  • 김경원;방소영;정종현
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.162-175
    • /
    • 2008
  • Gyeongju, which was the central city of the ancient civilization at Silla Kingdom, has various kinds of stone cultural properties. It is significantly important to preserve historical sources of Korea. However, recent air quality data measured in Gyeongju did not show good air quality level. In order to investigate variation of the concentration of the air pollutants with meteorological condition, an air quality monitoring and an aerosol sampling were conducted during the intensive monitoring period in Gyeongju. Impacts of the meteorological factors on the air pollutants were also analyzed based on the air mass pathway categories using HYSPLIT model and the local wind patterns using MM5 model. The prevailing air mass pathways were classified into four categories as following; category I affected by easterly marine aerosols, category II affected by northwesterly continental aerosols, category III affected by southwesterly continental aerosols, and category IV affected by northerly continental aerosols. The concentrations of the air quality standards were relatively lower during the fall intensive monitoring period. At that time, the easterly marine air mass pattern was dominated. The seasonal average mass concentration of $PM_{10,Opt}$, which optically measured at the monitoring site, was the highest value of $77.6{\pm}28.3\;{\mu}g\;m^{-3}$ during the spring intensive monitoring period but the lowest value of $20.1{\pm}5.3\;{\mu}g\;m^{-3}$ during the fall intensive monitoring period. The concentrations of $SO_2$ and CO were relatively higher when the air mass came from the northwestern continent or the northern continent. The concentrations of ${SO_4}^{2-}$ and ${NO_3}^-$ increased under the northwesterly continental condition. It was estimated that the acidic aerosols were dominated in the atmosphere of Gyeongju when the air mass came from the continental regions.

서울시의 2005~2006년 도시배경 및 상층측정망의 대기질 특성 분석 (Analysis on Air Quality Characteristics through Air Quality Monitoring Stations in urban Background and High Altitude in 2005~2006 in Seoul)

  • 유승성;전재식;정권;신은상;정부전;류리나;우정헌;선우영
    • 환경영향평가
    • /
    • 제20권1호
    • /
    • pp.49-59
    • /
    • 2011
  • The results of comparing $PM_{10}$ concentration between 'Namsan' and 'Yongsan-gu' air quality monitoring stations show similar values with averaged concentration in the whole Seoul. The correlation factors in both sites were 0.865, 0.828 in 2005, 2006, respectively. For 'Bukhansan' and 'Gangbuk-gu' air quality monitoring stations, different from the results mentioned above, they showed clear differences as altitude changes. PM10 concentration in 'Bukhansan' monitoring stations was 10 ${\mu}g/m^3$ lower than 'Gangbuk-gu' monitoring station which is located near the ground. Also, averaged PM10 concentration in 'Bukhansan' and 'Gangbuk-gu' monitoring stations was lower than that in the whole Seoul. When comparing $NO_2$ concentration between 'Namsan' and 'Yongsan-gu' monitoring stations, $NO_2$ concentration in 'Namsan' monitoring station was lower than 'Yongsan-gu' monitoring station. For $NO_2$ concentration in 'Bukhansan', 'Gangbuk-gu' and 'the whole Seoul', there were the same pattern in 'Gangbuk-gu' and the 'the whole Seoul' and low values in 'Bukhansan' monitoring station. The correlation factors of $NO_2$ concentration in 'Bukhansan' and 'Gangbukgu' was 0.525, 0.549 in 2005, 2006, respectively, which stands for low correlationship.

군집분석을 활용한 부산지역 오존, PM10 측정소의 유사성 분석 (An Analysis of Similarity between Air Quality Monitoring Stations in Busan using Cluster Analysis)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제26권8호
    • /
    • pp.927-938
    • /
    • 2017
  • This study was conducted to determine correlations and similarity between the ozone and $PM_{10}$ data of 19 air quality monitoring stations in Busan from 2013 to 2016, using correlation and cluster analyses. Ozone concentrations ranged from $0.0278{\pm}0.0148ppm$ at Gwangbok to $0.0378{\pm}0.017ppm$ at Taejongdae and were high in suburban areas, such as Yongsuri and Gijang, as well as in coastal areas, such as Jaw, Gwangan, Taejongdae and Noksan. $PM_{10}$ concentrations ranged from $37.2{\pm}25.0ug/m^3$ at Gijang to $58.3{\pm}32.2ug/m^3$ at and Jangrim. $PM_{10}$ concentrations were high in the west, exceeding the annual ambient air quality standard of $50ug/m^3$. Positive correlations were observed for ozone at most stations, ranging from 0.61 between Taejongdae and Sujeong to 0.92 between Bugok and Myeongjang. The correlation coefficients of $PM_{10}$ between stations ranged from 0.62 between Jangrim and Jaw to 0.9 between Gwangbok and Sujeong. Yeonsan, Daeyeon, and Myeongjang were highly correlated with other stations, so they needed to be reviewed for redundancy. Ozone monitoring stations were initially divided into two sections, north-western areas and suburban-coastal areas. The suburban-coastal areas were subsequently divided into three sections. $PM_{10}$ monitoring stations were initially divided into western and remaining areas, and then the remaining areas were subsequently divided into three sections.

2009년 서울지역 황사 및 고농도 미세먼지 사례 시 미세먼지의 화학성분 특성 (Chemical Characteristics of Ambient Aerosol during Asian Dusts and High PM Episodes at Seoul Intensive Monitoring Site in 2009)

  • 박승명;문광주;박종성;김현재;안준영;김정수
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.282-293
    • /
    • 2012
  • This study aimed to show the chemical characteristics of $PM_{10}$ and $PM_{2.5}$ during Asian dust (AD) events and high PM episodes observed in Seoul. Time-resolved chemical composition of $PM_{10}$ or $PM_{2.5}$ was monitored in 1 hour interval using ambient ion monitor, semi-continuous carbon monitor, and on-line XRF spectrometer at Seoul intensive monitoring site in 2009. Considering that AD events were classified into three different cases according to the source area and pathway, the concentrations of ammonium-sulfate and trace metal components were relatively high when the AD were occurred in Gobi and inner-mongolia and transported across the Bohai bay. In addition, the influence of alkaline dust, which carried from saline land located in the northeastern China, was observed when the AD was originated from Gobi, inner-mongolia, and Manchuria. Except AD events, the high PM episodes observed in Seoul were impacted by various anthropogenic sources such as biomass burning, motor vehicle, oil combustion and road dust.

Characteristics of PM10, PM2.5 and PM2.5/PM10 Ratio in Air Monitoring Stations in Gyeongnam

  • Park, Jeong-Ho;Suh, Jeong-Min
    • 한국환경과학회지
    • /
    • 제27권10호
    • /
    • pp.925-931
    • /
    • 2018
  • The characteristics of $PM_{10}$, $PM_{2.5}$ and Ratio($PM_{2.5}/PM_{10}$) of 11 urban air monitoring stations in Gyeongnam were analyzed for the last 3 years('15~'17). The average of the all stations was $PM_{10}\;45{\mu}g/m^3$, $PM_{2.5}\;24{\mu}g/m^3$ and Ratio 0.54, and annual reduction rates were $PM_{10}-2.9%$, $PM_{2.5}-2.7%$ and Ratio -1.2%, respectively. The seasonal characteristics of $PM_{10}$ were spring $54{\mu}g/m^3$ > winter $48{\mu}g/m^3$ > summer/autumn $40{\mu}g/m^3$, $PM_{2.5}$ were spring/winter $26{\mu}g/m^3$ > summer 23 > autumn $22{\mu}g/m^3$ and Ratio were summer 0.56 > winter 0.55 > autumn 0.54 > spring 0.51, respectively. The hourly characteristics of $PM_{10}$ were $11{\mu}g/m^3$ higher than 09:00~12:00 at 03:00~06:00, $PM_{2.5}$ were $6{\mu}g/m^3$ higher than 09:00~12:00 at 17:00~18:00 and Ratio were 0.07 higher than 04:00~06:00 at 19:00. By site, the highest concentration of $PM_{10}$ was YJ site $53{\mu}g/m^3$ and $PM_{2.5}$ was HW site $28{\mu}g/m^3$. And Ratio at HD site showed the largest reduction from '15 0.62 to '17 0.52.

지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징 (On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002)

  • 김철희;박일수;이석조;김정수;진형아;성한규
    • 한국대기환경학회지
    • /
    • 제20권2호
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

GIS기반 PM10 미세먼지농도 실시간 서비스 (GIS-based PM10 Concentration Real-time Service)

  • 윤훈주;한광인;조성호;정병혁
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.585-592
    • /
    • 2015
  • In this study, by applying mobile based GIS and image analysis of particulate matter ($PM_{10}$) concentration in Seoul and Ulsan in Korea, to identify the user's location and also implemented the application to information exchange. It strengthened citizens' access to air quality information through the application and derived the expanded environment information sharing through real-time user participation. Through atmospheric concentrations image analysis, it showed a new environmental information construction possibility. It had the effect of expanding the information collecting through the local user participation on the limited information collected area which place is not yet constructed atmospheric monitoring network. Location-based particulate matter information service application provides a user location's $PM_{10}$ information from the 25 urban air monitoring network real-time database of the Ministry of Environment. Furthermore, if the user sent a picture of the atmosphere to the server, should match the image density values of the database and express on Seoul's maps through the IDW interpolation. And then a $PM_{10}$ concentration result is transmitted to user in real time.