• Title/Summary/Keyword: PM10 농도

Search Result 2,416, Processing Time 0.033 seconds

Characteristics of the Springtime Weekday/Weekend on Mass and Metallic Elements Concentrations of PM10 and PM2.5 in Busan (부산지역 봄철 주중/주말의 PM10과 PM2.5 질량농도와 금속이온농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.777-784
    • /
    • 2015
  • This study investigates weekday/weekend characteristics of $PM_{10}$ and $PM_{2.5}$ concentration and metallic elements in Busan in the springtime of 2013. $PM_{10}$ concentration on weekday/weekend were 77.54 and $67.28{\mu}g/m^3$, respectively. And $PM_{2.5}$ concentration on weekday/weekend were 57.81 and $43.83{\mu}g/m^3$, respectively. Also, $PM_{2.5}/PM_{10}$ concentration ratio on weekdays/weekend was 0.75 and 0.65, respectively. The contribution rates of Na to total metallic elements in $PM_{10}$ on weekday/weekend were 38.3% and 38.9%, respectively. It would be useful in control effectively with management of urban fine particle to understand characteristics of fine particle concentration on weekday/weekend.

Acute Effects of Ethanol on Blood Pressure and Renal Function in Rat (Ethanol 급성투여(急性投與)가 흰쥐의 혈압(血壓)과 신기능(腎機能)에 미치는 영향(影響))

  • Bae, Gui-Sook;Park, Jae-Sik;Lee, Won-Jung
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.103-109
    • /
    • 1981
  • In order to determine the dose-response relationship of ethanol on blood pressure and renal function, 2 doses of ethanol were intubated into albino rats. For a direct measurement of arterial blood pressure, a polyethylene catheter(PE 10) was implanted in the abdominal aorta, and the other end of the catheter was pulled out of the back of the neck. The experiment was conducted after the rats recovered from the surgery. After emptying their bladders, the rats were placed in a metabolism cage. Mean arterial pressure (MAP) was measured and arterial blood samples were collected through the catheter. Following the collection of the control urine sample, 1 ml of 10 g% (low dose), or 30 g% (high dose) of ethanol/100 g BW was intubated. 1 ml of water/100 g BW was intubated into the control group. MAP and blood samples were taken every hour, and urine samples were collected every 90 min for 3 hours. Blood alcohol concentrations reached a peak at 1 hour (low dose: $105.0{\pm}7.5$, high dose: $214.7{\pm}20.2\;mg%$) and decreased linearly thereafter. Following alcohol ingestion, MAP began to decrease at 15 min and remained at a significantly low level thoughout the 3 hours experimental period(low dose: $112{\pm}2{\rightarrow}102{\pm}4$, high dose: $117{\pm}2{\rightarrow}100{\pm}8\;mmHg$). Urine Flow increased markedly during the first 90 min of ethanol ingestion (low dose: $0.88{\pm}0.20{\rightarrow}1.04{\pm}0.22$, high dose: $0.56{\pm}0.11{\rightarrow}1.35{\pm}0.18\;ml/1.5\;hr$) and decreased during the second 90 min period(low dose: $0.25{\pm}0.06$, high dose: $0.22{\pm}0.06\;ml/1.5\;hr$). Urine flow of the control group decreased gradually during the experiment $(0.88{\pm}0.10{\longrightarrow}0.59{\pm}0.09{\rightarrow}0.45{\pm}0.09\;ml/1.5\;hr)$. These results indicate that the blood-pressure-lowering and diuretic effects of ethanol are dose-related: higher doses of ethanol produce a greater decrease in blood pressure and greater diuresis.

  • PDF

Characteristics of Indoor PM2.5 and the effect of air purifier and ventilation system on Indoor PM2.5 in the Knowledge Industrial Center office during the atmospheric PM2.5 warning (초미세먼지 주의보 시 지식산업센터 사무실의 실내 초미세먼지 농도 특성과 공기청정기와 환기장치의 영향)

  • Ji, Jun-Ho;Joo, Sang-Woo
    • Particle and aerosol research
    • /
    • v.16 no.3
    • /
    • pp.65-72
    • /
    • 2020
  • In this study, the indoor fine dust concentration in an office of the Korea Knowledge Industry Center was measured for about 80 hours when the concentration of atmospheric PM2.5 was very high. The effect of the operation of the air cleaner and the forced ventilation system on the indoor PM2.5 was investigated, and the particle size distribution of the indoor and outdoor particles was analyzed. When forced ventilator and air purifiers were partially used, the indoor PM2.5 concentrations were maintained between 27.7 ㎍/㎥ and 32.9 ㎍/㎥ when the atmospheric PM2.5 was 127.7 ㎍/㎥ to 141.6 ㎍/㎥ during working hours. It is more effective to operate the air purifier without operating the forced ventilation system when the concentration of the PM2.5 is high since the PM2.5 penetrating the installed filter is continuously introduced indoor from the outside.

Development of statistical forecast model for PM10 concentration over Seoul (서울지역 PM10 농도 예측모형 개발)

  • Sohn, Keon Tae;Kim, Dahong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.2
    • /
    • pp.289-299
    • /
    • 2015
  • The objective of the present study is to develop statistical quantitative forecast model for PM10 concentration over Seoul. We used three types of data (weather observation data in Korea, the China's weather observation data collected by GTS, and air quality numerical model forecasts). To apply the daily forecast system, hourly data are converted to daily data and then lagging was performed. The potential predictors were selected based on correlation analysis and multicollinearity check. Model validation has been performed for checking model stability. We applied two models (multiple regression model and threshold regression model) separately. The two models were compared based on the scatter plot of forecasts and observations, time series plots, RMSE, skill scores. As a result, a threshold regression model performs better than multiple regression model in high PM10 concentration cases.

Analysis of the Factors Influencing PM10 & PM2.5 in Korea by Panel Quantile-Regression (패널 분위회귀분석을 통한 한국의 미세먼지 국내외 영향요인 분석)

  • Kim, Haedong;Kim, Jaehyeok;Jo, Hahyun
    • Environmental and Resource Economics Review
    • /
    • v.31 no.1
    • /
    • pp.85-112
    • /
    • 2022
  • This study analyzed the influence of domestic and Chinese factors on fine dust(PM10 & PM2.5) in Korea by using the panel quantile regression. Daily analysis was conducted for 11 regions in Korea. For domestic factors, electricity demand and traffic volume, and for Chinese factors, interaction term of Chinese three cities' fine dust and the domestic west wind are used. As a result, the influence of domestic factors was different when the domestic fine dust concentration was high and low. When the fine dust concentration was low, electricity demand had a positive effect only on PM2.5, and didn't affect PM10 in the national analysis. In regional analysis, the amount of electricity demand had a significant effect on fine dust and ultrafine dust only in the capital area and Chungcheong. Electricity demand was found to significantly increase both PM2.5 and PM10 when it was high. On the other hand, it was confirmed that the Chinese factor always had a significant effect regardless of the concentration of PM10 and PM2.5. Therefore, in order to solve the problem of high concentration of fine dust, in addition to international cooperation, the reduction of PM2.5 generated by domestic thermal power generation should also be strengthened compared to the present.

Optimum Concentration of Alizarin Complexone (ALC) for Otolith Marking of Pacific Cod Gadus macrocephalus (대구 Gadus macrocephalus 이석 표지를 위한 Alizarin Complexone의 최적 농도)

  • Kim, Tae Jin;Lee, So Gwang;Gwak, Woo Seok
    • Korean Journal of Ichthyology
    • /
    • v.20 no.4
    • /
    • pp.272-278
    • /
    • 2008
  • Optimum concentration of alizarine complexone (ALC) for staining of otoliths for Pacific cod was determined by examination of stained quality, growth and survival rates. Small juveniles ($34.1{\pm}1.8mm$ TL, $mean{\pm}SD$) were immersed in four different concentrations (20, 40, 60, 80 mg/L) and large ones ($73.8{\pm}1.2mm$ TL, $mean{\pm}SD$) in five different concentrations (1, 5, 10, 20, 40 mg/L) of ALC for 24 hrs. The fish were then reared and observed for 14 days. The stained quality of otoliths was evaluated by dividing them into four grades by the presence of fluorescent stains on the otoliths under G-excited UV light. The small juveniles stained with the different ALC concentrations had 100% staining success, and their growth rate and body weight did not differ significantly between treatments. Optimal ALC concentration for the smaller juveniles was 20 mg/L in the present experiment. On the other hand, distinct fluorescent rings were confirmed on otoliths of larger juveniles in the 10 mg/L treatment with high survival rate. These results suggest that ALC staining at concentrations of 10 mg/L with larger juveniles will be helpful for release-recapture experiments for stock enhancement of Pacific cod.

PM10 Concentration and Chemical Composition in Western Area of Busan (부산 서부지역의 대기 중 PM10 농도와 화학적 조성 분석)

  • 황용식;전병일
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.627-633
    • /
    • 2003
  • The PM$_{10}$ concentration and chemical composition in an western area of Busan were surveyed between March, 2001 and February, 2002. The mean concentration was 98.2 $\mu\textrm{g}$/㎥ with a range of 18.1 to 330.6 $\mu\textrm{g}$/㎥. The magnitude of metallic elements in PM$_{10}$ is as follows in decreasing order: K>Ca>Na>Al>Fe. The mean values of crustal enrichment factors for four elements (Cd, Ni, Pb and Zn) were all higher than 10, which presumably resulted from the effect of anthropogenic origin. Moreover, the wintertime values were higher than springtime and summertime values, possibly due to emissions westerly transported from industries around this area. The contribution of soil particle to airborne particle in the study area was estimated to be 9.5%.

An Analysis of the Effects of Fine Dust Reduction Policies on PM10 Concentration and Health Using System Dynamics (시스템다이내믹스를 활용한 미세먼지 저감 정책이 미세먼지 농도와 건강에 미치는 영향 분석)

  • Seho Lee;Jung Eun Kang;Ji-Yoon Lee;Minyeong Park;Ji Yoon Choi
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.318-337
    • /
    • 2023
  • This study utilizes system dynamics to examine the effects of fine dust reduction policies on PM10 concentration and health. System dynamics has the advantage of modeling the dynamic and circular relationship between PM10 emission sources, reduction policies, PM10 concentration, and health effect. The study created policy scenarios for Korea's representative fine dust reduction policies - industrial PM10 emission control, diesel vehicle regulation, expansion of electric vehicles, and expansion of parks and green areas - and compared the results with the 2030 baseline if the current trend is maintained. The analysis showed that the policy of supporting electric vehicles reduced PM10 concentration by 0.21 ㎍/m3 and reduced the number of people with circulatory diseases by 494, and the effect was evenly distributed across the country. The industrial emissions regulation scenario resulted in the highest PM10 concentration reduction of 0.22 ㎍/m3, but had a lower reduction in the number of people affected (358) than the EV support strategy, which could be attributed to the fact that this policy had a particularly high PM10 reduction effect in industrial areas such as Danyang-gun, Chungcheongbuk-do, and Sahagu, Busan. As a policy implication, this study suggests that it is necessary to apply fine dust policies tailored to the characteristics of local emission sources.

Dust Spatial Distribution and Emission of Tunnel Ventilated Windowless Broiler Building (터널환기 무창육계사의 분진크기별 분포와 배출농도에 관한 연구)

  • Choi, H.C.;Yeon, G.Y.;Spmg, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • This study investigated the spatial distribution of dust originating from tunnel-ventilated windowless broiler building measuring 12 m wide, 61 m long, with a side wall height of 3 m and a capacity of 16,982 birds. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10\;{\mu}m$(PM10), $2.5\;{\mu}m$(PM2.5), and $1\;{\mu}m(PM1)$ were measured at 30 minutes interval by using GRIMM Aerosol Monitor (GRIMM AEROSOL). The spatial distribution of dust showed the lower dust concentration in the inlet than in the outlet of the tunnel ventilation, and dust concentration decreasing as the dust size decreased, as follows: $317.9\;{\mu}g/m^3$ TSP; $74.7{\mu}m/m^3$ PM10; $9.7\;{\mu}g/m^3$ PM2.5; and $6.2\;{\mu}g/m^3$ PM1 in the inlet; and $2,678.5\;{\mu}g/m^3$ TSP; $555.5\;{\mu}g/m^3$ PM10; $33.3\;{\mu}g/m^3$ PM2.5; and $10.2\;{\mu}g/m^3$ PM1 in the outlet. The dust concentration emitted from the tunnel ventilated fan was $446.6\;{\mu}g/m^3$ TSP; $129.1\;{\mu}g/m^3$ PM10; $15.8\;{\mu}g/m^3$ PM2.5; and $6.1\;{\mu}g/m^3$ PM1 in the 3 meters from the fan and $25.1\;{\mu}g/m^3$ TSP; $8.8\;{\mu}g/m^3$ PM10; $5.6\;{\mu}g/m^3$ PM2.5; and $4.9\;{\mu}g/m^3$ PM1 in the 50 meters from the fan.

  • PDF

A Study on the Trends of Air Quality and Characteristics in Seosan Area of Korean Penninsula (서산지역의 대기질 경년변화 특성에 관한 연구)

  • Shon, Byung-Hyun;Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.779-786
    • /
    • 2008
  • This study was performed to evaluate the characteristics of current air quality and to examine the monthly and yearly variation of $SO_2,\;O_3,\;CO,\;NO_2$, and fine particulate matter(PM-10) concentration in Seosan for the period of 1998-2006. During the recent 3 years, from 2004 to 2006, the yearly mean concentration of $SO_2,\;NO_2$, and PM-10 remained stability but CO and $O_3$ are gradually decreased. The monthly mean concentration of $NO_2$, CO, and $SO_2$ were high in the winter season and decreased steadily to the summer season, but the maximum concentration of $O_3$ and PM-10 appeared in the springtime. The number of days exceeding 24-hour standards for PM-10 were 54 times at Dokgodri and 25 times at Dongmundong. The number of sampling days exceeding the 1-hour and 8-hour standards for $O_3$ were 68 and 210 times at Dongmundong and at Dokgotri 93 and 213 times, respectively.