• Title/Summary/Keyword: PM-2.5 sampling method

Search Result 107, Processing Time 0.034 seconds

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Characteristics of Chemical Species in $PM_{205}$ during the Winter in Kangwha (강화도 지역에서 겨울철 $PM_{205}$의 화학적 성분 특성)

  • 여현구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.4
    • /
    • pp.309-316
    • /
    • 2000
  • Chemical compositions of air pollutants with fine particles (<2.5 ${\mu}{\textrm}{m}$, PB2.5) were evaluated at background site. Kangwha. in Korea during the winter season. The data set was obtained for seventeed days with 24-hour sampling from December 11 to 16, 1996 and from January 9 to 1997. The chemical species have been measured {{{{ {SO }`_{4 } ^{2- } }}}}, {{{{ { NO}`_{3 } ^{- } }}}}, {{{{ { NH}`_{4 } ^{+ } }}}}. OC and EC in the particulate phase, NH3 HNO3, HCl and SO2 in the gas phase using the three stage filter pack method. Mean concentration ($\mu\textrm{g}$/m3) of this study were : 35.42 for PM2.5 8.78 for organic carbon (OC) 7.25 for nss {{{{ {SO }`_{4 } ^{2- } }}}}, 4.94 for {{{{ { NO}`_{3 } ^{- } }}}}, 3.58 for {{{{ { NH}`_{4 } ^{+ } }}}} and 1.48 for elemental carbon (EC) respectively. Contributive rates of major particulate components in PM2.5 were OC (25%) nss- {{{{ {SO }`_{4 } ^{2- } }}}}(20%) ,{{{{ { NO}`_{3 } ^{- } }}}}(14%) {{{{ { NH}`_{4 } ^{+ } }}}}(10%) and EC (4%) respectively and these components could be accounted for 73% of PM2.5 mass. Reactive forms of {{{{ { NH}`_{4 } ^{+ } }}}} were considered as NH4HO3 and NH4{{{{ {SO }`_{4 } ^{2- } }}}} during the sampling periods. {{{{ { NO}`_{3 } ^{- } }}}}/({{{{ { NO}`_{3 } ^{- } }}}} + HNO3) and {{{{ {SO }`_{4 } ^{2- } }}}}/({{{{ {SO }`_{4 } ^{2- } }}}} + SO2) were calculated 0.8 and 0.9 respectively. Most of these compounds might be formed in partiiculate phase in the air. Correlation coefficient between OC and EC was 0.866 which might have the same sources during the sampling periods,.

  • PDF

Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents (공기중 유기용제 혼합물 측정방법의 비교연구)

  • Chun, Mee Hye;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF

Validation of an Extraction Method for the Determination of Airborne MWFs using Alternative Solvents (대체용매를 이용한 금속가공유 측정방법 타당성 평가)

  • Jeong, Jee Yeon;Baek, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.91-100
    • /
    • 2006
  • The purpose of this study was to validate alternative method by using non-carcinogenic, and less toxic solvents than NIOSH analytical method 5524 for measuring the airborne MWFs in workplaces. In laboratory tests, the ETM solvents(mixture of same volume for ethyl ether, toluene, and ethanol) were selected. The alternative method of analyzing MWFs, referred to as the ETM solvent extraction method, showed 0.04 mg/sample as LOD, and 0.15 mg/sample as LOQ. The analytical precision (pooled CV, coefficient of variation) of the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was 1.5%, 2.0%, 2.6%, 1.6%, respectively, which was similar to the precision (2.6%) of NIOSH analytical method (NIOSH 0500) for total dust. The analytical accuracy by recovery test, spiked mass calculated as extractable mass, was almost 100%. As the result of storage stability test, metalworking fluid samples should be stored in refrigerated condition, and be analyzed in two weeks after sampling. The 95% confidence limit of the estimated total standard error for the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was ${\pm}12.6%$, ${\pm}12.5%$, ${\pm}14.0%$, and ${\pm}13.6%$, respectively, which satisfied the OSHA sampling and analytical criteria.

Investigation of Chemical Characteristics of $PM_{2.5}$ during Winter in Gwangju (겨울철 광주지역 $PM_{2.5}$의 화학적 특성 조사)

  • Ko, Jae-Min;Bae, Min-Suk;Park, Seung Shik
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.89-102
    • /
    • 2013
  • 24-hr $PM_{2.5}$ samples were collected from January 19 through February 27, 2009 at an urban site of Gwangju and analyzed to determine the concentrations of organic and elemental carbon(OC and EC), water-soluble OC(WSOC), eight ionic species($Na^+$, $NH^{4+}$, $K^+$, $Ca^{2+}$, $Mg^{2+}$, $Cl^-$, ${NO_3}^-$ and ${SO_4}^{2-}$), and 22 elemental species. Haze phenomena was observed during approximately 29%(10 times) of the whole sampling period(35 days), resulting in highly elevated concentrations of $PM_{2.5}$ and its chemical components. An Asian dust event was also observed, during which $PM_{2.5}$ concentration was 64.5 ${\mu}g/m^2$. Crustal materials during Asian dust event contributed 26.6% to the $PM_{2.5}$, while lowest contribution(5.1%) was from the haze events. OC/EC and WSOC/OC ratios were found to be higher during haze days than during other sampling days, reflecting an enhanced secondary organic aerosol production under the haze conditions. For an Asian dust event, enhanced concentrations of OC and secondary inorganic components were also found, suggesting the further atmospheric processing of precursor gases during transport of air mass to the sampling site. Correlations among WSOC, EC, ${NO_3}^-$, ${SO_4}^{2-}$, and primary and secondary OC fractions, which were predicted from EC tracer method, suggests that the observed WSOC could be formed from similar formation processes as those of secondary organic aerosol, ${NO_3}^-$ and ${SO_4}^{2-}$. Results from principal component analysis indicate also that the observed WSOC was strongly associated with formation routes of the secondary organic and inorganic aerosols.

Comparison of Dust Exposure Levels among Farmers with and without Feeding (사료 급이 유무에 따른 돈사 작업자의 분진 노출량 비교)

  • Paik, Jong Min;Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.103-107
    • /
    • 2013
  • Objectives: The principal purpose of this study is to statistically compare dust levels among farmers with and without feeding in a nursery pig building. Methods: Total dust and respirable dust were measured by personal sampling method, and TSP and PM10 were monitored by the direct recording method in the pig building. Results: IIn the personal samples, mean exposure levels of total and respirable dust were higher among the farmers who conducted feeding compared to farmers who did not. A significant difference between farmers with feeding and farmers without feeding was found in total dust concentration(p<0.05), whereas there was no significant difference in respirable dust concentrations. In real-time monitoring of dust based on area sampling, the highest levels of total and respirable dust were detected in the feeding time periods; $4.33{\pm}2.57mg/m^3$ for TSP and $2.53{\pm}1.02mg/m^3$ for PM10, respectively. During time periods without feeding, the levels of total and respirable dust ranged from 1 to $2mg/m^3$ and from 0.5 to $1.5mg/m^3$, respectively. Conclusions: In terms of association of feeding work and air sampling location, the mean concentrations of total and respirable dust were highest in area sampling with feeding and lowest in personal sampling without feeding. However, a significant difference among groups investigated according to air sampling condition was found in total dust.

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Reliability and Accuracy of the Deployable Particulate Impact Sampler for Application to Spatial PM2.5 Sampling in Seoul, Korea (서울시 PM2.5 공간 샘플링을 위한 Deployable Particulate Impact Sampler의 성능 검증 연구)

  • Oh, Gyu-Lim;Heo, Jong-Bae;Yi, Seung-Muk;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.277-288
    • /
    • 2017
  • Previous studies of health effects of $PM_{2.5}$ performed spatial monitoring campaigns to assess spatial variability of $PM_{2.5}$ across people's residences. Highly reliable portable and cost-effective samplers will be useful for such campaigns. This study aimed to investigate applicability of the Deployable Particulate Impact Sampler(DPIS), one of the compact impact samplers, to spatial monitoring campaigns of $PM_{2.5}$ in Seoul, Korea. The investigation focused on the consistency of $PM_{2.5}$ concentrations measured by DPISs compared to those by the Low-volume Cyclone sampler (LCS). LCS has operated at a fixed site in the Seoul National University Yeongeon campus, Seoul, Korea since 2003 and provided qualified $PM_{2.5}$ data. $PM_{2.5}$ sampling of DPISs was carried out at the same site from November 17, 2015 through February 3, 2016. $PM_{2.5}$ concentrations were quantified by the gravimetric method. Using a duplicated DPIS, we confirmed the reliability of DPIS by computing relative precision and mean square error-based R squared value ($R^2$). Relative precision was one minus the difference of measurements between two samplers relative to the sum. For accuracy, we compared $PM_{2.5}$ concentrations from four DPISs (DPIS_Tg, DPIS_To, DPIS_Qg, and DPIS_Qo) to those of LCS. Four samplers included two types of collection filters(Teflon, T; quartz, Q) and impaction discs(glass fiber filter, g; pre-oiled porous plastic disc, o). We assessed accuracy using accuracy value which is one minus the difference between DPIS and LCS $PM_{2.5}$ relative to LCS $PM_{2.5}$ in addition to $R^2$. DPIS showed high reliability (average precision=97.28%, $R^2=0.98$). Accuracy was generally high for all DPISs (average accuracy=83.78~88.88%, $R^2=0.89{\sim}0.93$) except for DPIS_Qg (77.35~78.35%, 0.82~0.84). Our results of high accuracy of DPIS compared to LCS suggested that DPIS will help the assessment of people's individual exposure to $PM_{2.5}$ in extensive spatial monitoring campaigns.

Comparison of PM2.5 Concentrations by Measurement Method (측정 방법에 따른 PM2.5 농도 비교)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Jisoo;Kim, Pilho;Han, Yu Kyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.515-520
    • /
    • 2017
  • $PM_{2.5}$ concentrations were measured using a cyclone, impactor (the U.S. Environmental Protection Agency well impactor ninety-six, WINS) and optical particle counter (OPC) at a campus site located in Yongin for the period August 2014 through March 2017. The concentrations from cyclone (Y) were generally higher than those from impactor(X); the best-fit line was Y=1.22X+5.64. The ratios of $PM_{2.5}/PM_{10}$ ranged from 0.61 to 0.66 when $PM_{2.5}$ concentrations from cyclones in selected studies were converted into those from impactors using a regression equation in this study. The slope of the best-fit line between OPC and impactor was close to 1 at 0.95, while that between OPC and cyclone was 0.72. After sampling, the flow rate in the low-volume air sampler with cyclone decreased by 3% on average, which did not have a significant effect on measured concentrations.