Characteristics of Particle Growth and Chemical Composition of High Concentrated Ultra Fine Dusts (PM2.5) in the Air around the Power Plant (고농도 초미세먼지 출현 시 발전소 주변 대기 입자 성장 및 화학조성 특성)

  • Suji, Kang;Jinho, Sung;Youngseok, Eom;Sungnam, Chun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.103-110
    • /
    • 2022
  • Ultrafine Particle number and size distributions were simultaneously measured at rural area around the power plant in Dangjin, South Korea. New Particle formation and growth events were frequently observed during January, 2021 and classified based on their strength and persistence as well as the variation in geometric mean diameter(GMD) on January 12, 21 and 17. In this study, we investigated mechanisms of new particle growth based on measurements using a high resolution time of flight aerosol mass spectrometer(HR-ToF-AMS) and a scanning mobility particle sizer(SMPS). On Event days(Jan 12 and 21), the total average growth rate was found to be 8.46 nm/h~24.76 nm/hr. These growth rate are comparable to those reported for other urban and rural sites in South Korea using different method. Comparing to the Non-Event day(Jan 17), New Particle Growth mostly occurred when solar radiation is peaked and relative humidity is low in daytime, moreover enhanced under the condition of higher precusors, NO2 (39.9 vs 6.2ppb), VOCs(129.5 vs 84.6ppb), NH3(11 vs 4.7ppb). The HR-ToF-AMS PM1.0 composition shows Organic and Ammoniated nitrate were dominant species effected by emission source in domestic. On the other hand, The Fraction of Ammoniated sulfate was calculated to be approximately 16% and 31% when air quality is inflow from China. Longer term studies are needed to help resolve the relative contributions of each precusor species on new particle growth characteristics.

A Study on the Particles Density Estimation in Seoul Metropolitan (서울시 미세먼지의 밀도 추정에 관한 연구)

  • Kim, Shin-Do;Kim, Chang-Hwan;Hwang, Ui-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • The variation of the particle size distribution and density as well as the chemical composition of aerosols is important to evaluate the particles. This study measured and analyzed airborne particles using a scanning mobility particle sizer (SMPS) system and an aerodynamic particle sizer (APS) at the University of Seoul during every season. The highest particle number concentration of airborne particles less than $0.9\;{\mu}m$, occurred in winter, while the highest particle number concentration of airborne particles more than $0.9\;{\mu}m$, occurred in spring. Mass concentration appeared highest at spring. Also, when we compared $\beta$-ray's mass concentration with calculated mass concentration by using the SMPS-APS system during each season, density of the winter is $1.92\;g/cm^3$, spring density is $1.64\;g/cm^3$, fall density is $1.57\;g/cm^3$. We found out that PM10 density was differ every season. However, while the calculated density is whole density for PM10 the density of each diameter was different. In this study the density estimation equation of the QCM cascade impactor measured mass concentration of each diameter.

Study on Aerosol Deposition Behavior of Cu Films According to Particle Size (입자 사이즈에 따른 Cu 필름의 에어로졸 성막 거동에 대한 연구)

  • Lee, Dong-Won;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.235-240
    • /
    • 2017
  • The effect of particle sizes on the aerosol deposition (AD) of Cu films is investigated in order to understand the deposition behaviors of metal powder during the AD process. The Cu coatings fabricated by using $2{\mu}m$ Cu powders had a dense microstructure, a high deposition rate ($1.6{\pm}0.2{\mu}m/min$), and low resistance ($9.42{\pm}0.4{\mu}{\Omega}{\cdot}cm$) compared to that from using Cu powder with a particle size greater than $5{\mu}m$. Also, from estimating the internal micro-strain of Cu films, the Cu coatings fabricated by using $2{\mu}m$ Cu particles exhibited a high micro-strain value of $3.307{\times}10^{-3}$. On the other hand, the strain of Cu coatings fabricated with $5{\mu}m$ particles was decreased to $2.76{\times}10^{-3}$. These results seem to show that the impacted Cu particles are compressed and flattened by shock waves, and that their bonding is associated with the high internal micro-strain caused by plastic deformation.

The Correlation between Radon (Rn222) and Particulate Matters (PM10, PM2.5, PM1.0) in Subway Tunnel in Seoul.

  • Versoza, Michael;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • Radon ($Rn^{222}$) is a radioactive gas and is found at high concentrations underground. Investigations were done in many years specifically on public transportations such as in the subway stations, concourses and platforms for these are located underground areas. This study correlates the $Rn^{222}$ concentrations with the Particulate Matter (PM) concentration for the gas could be attached or trapped inside these particles. It was done on the opening subway tunnel of Miasageori Station going to Mia Station (Line 4) last August 2016. Based on the result, the $Rn^{222}$ were more influenced on the mass ratio (%) of PM present in the air instead of its mass concentration (${\mu}g/m^3$). As the $PM_{10}$ mass ratio increases ($42.32{\pm}1.03%$) during morning rush-hours, radon starts to increase up to $0.97{\pm}0.03pCi/L$. But during the afternoon $Rn^{222}$ concentrations decreased while the composition were stable at $22.96{\pm}3.0%$, $39.04{\pm}0.6%$ and $38.01{\pm}0.3%$ in $PM_1$, $PM_{2.5}$ and $PM_{10}$ respectively. It was then assumed that it could be the composition of the morning hours of the station were influencing the concentration of the radon.

Developing a Method for Detecting the Asian dust event Among High $PM_{10}$ events Using Aerodynamic Particle Sizer (APS) (Aerodynamic Particle Sizer (APS)를 이용한 고농도 $PM_{10}$ 사례 중 황사 판별기법 개발)

  • Lee, Young-Gon;Cho, Chun-Ho;Kim, Myoung-Soo
    • Atmosphere
    • /
    • v.18 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • Log normalized volume size distribution (dV/dlog$D_p$) with 52 size ranges from 0.5 to $20.0{\mu}m$ was measured for the cases of high $PM_{10}$ mass concentration (> $200{\mu}gm^{-3}$) using the Aerodynamic Particle Sizer (APS) at the Korea Global Atmosphere Watch Center (KGAWC) from 6 April, 2006 to 5 April, 2007. Black Carbon (BC), gaseous pollutants of $NO_X$ and $SO_2$ and ${\AA}ngstr\ddot{o}m$ exponent were also measured to examine the properties of the volume size distribution. From distinct difference of the high volume concentration (> $100{\mu}m^3cm^{-3}$), the volume size distribution for each event day was clasified into four types: (1) Type 1 had the high volume concentration for supermicron particles from 2.3 to $6.0{\mu}m$ and maximum average volume concentration was $160.7{\mu}m^3cm^{-3}$ at $3.5{\mu}m$. (2) Type 2 represented the high volume concentration in the both size range of submicron ($0.7-1.0{\mu}m$) and supermicron particles ($2.1-4.1{\mu}m^3cm^{-3}$ and $136.2{\mu}m^3cm^{-3}$ were found at 0.8 and $3.3{\mu}m$ respectively. (3) Type 3 showed the high volume concentration in the size range of $0.5-3.5{\mu}m$ and highest volume concentration of $201.1{\mu}m^3cm^{-3}$ at the particle size bin of $0.8{\mu}m$. (4) Type 4 was characterized by the high volume concentration for the fine particles less than $1.2{\mu}m$ and very high concentration of $446.8{\mu}m^3cm^{-3}$. ${\AA}ngstr\ddot{o}m$ exponent, concentration of gaseous ($NO_X$ and $SO_2$), and particle (BC) pollutants suggested that Type 1 was a typical volume size distribution for the Asian dust and Type 3 provided transportation of air pollutants. The distribution in Type 2 found to have both characteristics of the Asian dust and air pollutants, and Type 4 was took place during the foggy atmosphere containing high density of local pollutants. Based on the properties of volume size distribution, we can identify the three major events contributing the increase of $PM_{10}$ mass concentration, and hope to provide a guideline for discriminating the Asian dust from high $PM_{10}$ events. More case studies and longeto advance this determination method.

Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions (측정방법 및 기상상태에 따른 PM-10 질량농도 비교)

  • Jung, Chang Hoon;Park, Jin Hee;Hwang, S.M.;Jung, Y.G.
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

Seasonal Characteristics of PM2.5 Water Content at Seoul and Gosan, Korea (서울과 고산의 PM2.5 수분함량 계절 특성)

  • Lee, Hyung-Min;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.1
    • /
    • pp.94-102
    • /
    • 2010
  • Water content of $PM_{2.5}$ (particles in the atmosphere with a diameter of less than or equal to a nominal $2.5{\mu}m$) was estimated by using a gas/aerosol equilibrium model, SCAPE2, for the particles collected at Seoul and Gosan, Korea. From measured and analyzed characteristics of the particles, the largest difference between Seoul and Gosan is the proportions of total ammonia (t-$NH_3$=gas phase $NH_3$+particle phase ${NH_4}^+$), total nitric acid (t-$HNO_3$=gas phase $HNO_3$+particle phase ${NO_3}^-$) and sulfuric acid ($H_2SO_4$). Even though both sites have sufficient t-$NH_3$ to neutralize acidic species such as $H_2SO_4$, t-$HNO_3$, and t-HCl (total chloric acid=gas phase HCl+particle phase $Cl^-$), equivalent fraction of t-$NH_3$ and t-$HNO_3$ are higher at Seoul and $H_2SO_4$ is higher at Gosan. Based on the modeling result, it is identified that the $PM_{2.5}$ at Seoul is more hygroscopic than Gosan if the meteorological conditions are the same. To reduce water content of $PM_{2.5}$, and thus, mass concentration, control measures for ammonia and nitrate reduction are needed for Seoul, and inter-governmental cooperation is required for Gosan.

Characteristics of Indoor PM2.5 and the effect of air purifier and ventilation system on Indoor PM2.5 in the Knowledge Industrial Center office during the atmospheric PM2.5 warning (초미세먼지 주의보 시 지식산업센터 사무실의 실내 초미세먼지 농도 특성과 공기청정기와 환기장치의 영향)

  • Ji, Jun-Ho;Joo, Sang-Woo
    • Particle and aerosol research
    • /
    • v.16 no.3
    • /
    • pp.65-72
    • /
    • 2020
  • In this study, the indoor fine dust concentration in an office of the Korea Knowledge Industry Center was measured for about 80 hours when the concentration of atmospheric PM2.5 was very high. The effect of the operation of the air cleaner and the forced ventilation system on the indoor PM2.5 was investigated, and the particle size distribution of the indoor and outdoor particles was analyzed. When forced ventilator and air purifiers were partially used, the indoor PM2.5 concentrations were maintained between 27.7 ㎍/㎥ and 32.9 ㎍/㎥ when the atmospheric PM2.5 was 127.7 ㎍/㎥ to 141.6 ㎍/㎥ during working hours. It is more effective to operate the air purifier without operating the forced ventilation system when the concentration of the PM2.5 is high since the PM2.5 penetrating the installed filter is continuously introduced indoor from the outside.

Effect of the Nishinoshima Volcanic Eruption on Fine Particulate Concentration in Busan in Early August 2020 (일본 니시노시마 화산 분출이 2020년 8월 초 부산지역의 미세먼지 농도에 미치는 영향)

  • Byung-Il Jeon
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1079-1087
    • /
    • 2022
  • This study investigated the effect of volcanic materials that erupted from the Nishinoshima volcano, Japan, 1,300 km southeast of the Busan area at the end of July 2020, on the fine particle concentration in the Busan area. Backward trajectory analysis from the HYSPLIT model showed that the air parcel from the Nishinoshima volcano turned clockwise along the edge of the North Pacific high pressure and reached the Busan area. From August 4 to August 5, 2020, the concentration of PM10 and PM2.5 in Busan started to increase rapidly from 1000 LST on August 4, and showed a high concentration for approximately 13 hours until 2400 LST. The PM2.5/PM10 ratio showed a relatively high value of 0.7 or more, and the SO2 concentration also showed a high value at the time when the PM10 and PM2.5 concentrations were relatively high. The SO42- concentration in PM2.5 in Busan showed a similar trend to the change in PM10 and PM2.5 concentrations. It rose sharply from 1300 LST on August 4, at the time where it was expected to have been affected by the Nishinoshima Volcano. This study has shown that the occurrence of high concentration fine particle in Busan in summer has the potential to affect Korea not only due to anthropogenic factors but also from natural causes such as volcanic eruptions in Japan.

Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology (대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구)

  • Park, Duck Shin;Kwon, Soon Bark;Cho, Young Min;Jang, Seong Ki;Jeon, Jae Sik;Park, Eun Young
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.