• Title/Summary/Keyword: PM tube

Search Result 405, Processing Time 0.028 seconds

Swelling and Drug Release Characteristics of PVP Hydrogel Polymerized by $\gamma$-Irradiation Method (김마선 조사법으로 합성한 PVP하이드로겔의 팽윤과 약물방출특성)

  • 심창구;오정숙;신병철
    • YAKHAK HOEJI
    • /
    • v.37 no.5
    • /
    • pp.511-519
    • /
    • 1993
  • The short and variabke transit of drug throught GI tracj and the inter-and intra-subject variations of the transit restrict the sustained drug absorption after oral adminstration. These restrictions may be solved by retaining the dosage forms in the stomach. Then the dosage form will act as a platform which releases the drug slowly and makes the GI absorption occur for a long time. In this study, as the platforms, PVP hydrogels were synthesized by chemical and y-irradiation method in the cylindrical test tube. The chemical method means the synthesis of the hydrogel by heating the mixed solution of N-vinyl-2-pyrrolidone [monomer], acrylated albumin [crosslinking agent], 2, 2'-agobis(2-methylpropionitrile) [initiator] and proxyphylline [drug] at $65^{\circ}C$ for 5 hr. The $\gamma$-irradiation method means the synthesis of the hydrogel by irradiation with $^{60}$ Co $\gamma$-ray of the mixed solution of the monomer, acrylated albumin, and flurbiprofen [drug] at room temperature with total 0.2 Mrad for 3 hr. Our intention is to design the hydrogel tablet (diameter : 1.20 cm, thickness : 0.60 cm) which swells in the gastric fluid after oral administration to such a size that passing through the pylorus could be inhibited during the period of drug release. After releasing drug, the hydrogel should be degraded by the enzymeatic digestion in the stomach, or by hydrolysis and eventually solubilized. Thus, in votro tests were performed to examine the factors that affect swelling and drug release from the PVP hydrogels. Experimental results show that the hydrogels swell to a size larger than the diameter of the pylorus(l.3$\pm$0.7 cm) and the hydrogel prepared by the chemical method is digested by pepsin. But the hydrogel prepared by the $\gamma$-irradiation method was not digested by the pepsin and just collapsed with time. Thus, the swelling of the hydrogel synthesized by $\gamma$-irradiation was independent albumin acrylation time and pepsin concentration. But drug content and radiation dose affected the swelling and drug release kinetics of the hydrogel. Drug release from the hydrigels was prolonged up to about 24 hr. Therefore, it was concluded that by adjusting these factors, the albumin-crosslinked PVP hydrogel synthesized by $\gamma$-irradiation method is expected to be retained in the stomach for up to 60hr and be a potential platform of drugs for long-term GI absorption.

  • PDF

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

BOND STRENGTH OF RESIN CEMENTS TO ZIRCONIA CERAMIC (지르코니아 세라믹과 레진 시멘트의 결합강도)

  • Chang Mun-Suk;Kim Ji-Hye;Cho Suck-Kyu;Bok Won-Mi;Song Kwang-Yeob;Park Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.426-437
    • /
    • 2005
  • Statement of problem : Although zirconium oxide ceramics are more and more commonly used in restorative dentistry, for many clinical applications only limited data can be found in the literature. However it is quite clear that hydrofluoric acid etching is impossible with zirconia ceramics. Therefore, other bonding techniques are required in order to lute these materials adhesively. Purpose : The purpose or this study was to evaluate the effects of surface treatments on shear bond strengths between two resin cements and a zirconia ceramic. Materials and methods : Experimental industrially manufactured yttrium-oxide-partially-stabilized zirconia ceramic discs (Adens, Korea) were used for this study. The ceramic specimens divided into five experimental groups and a control group (as received). Five surface treatments were studied 1) sandblasting with 110$\mu$m $Al_2O_3$ at 3 bars pressure 13 seconds at a distance of 10 mm, 2) flame-treated with the Silano-Pen for 5 $s/cm^3$, 3) grinding with a diamond bur. 4) sandblasting + Silano-Pen treatment, 5) diamond bur preparation + Silano-Pen treatment. Acrylic plastic tube (5 mm in height and 3 mm in diameter) were filled with composite to fabricate composite cylinders The composite cylinders were bonded to the ceramic specimens with either Superbond C&B or Panavia F resin luting agents. All cemented specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed 1mm/min; the maximum load at fracture was recorded. Sheat bond strength data were analyzed with oneway analysis of variance and Tukey HSD tests (P<.05). Treated ceramic surfaces and fracture surfaces after shear testing were examined morphologically using scanning electron microscope. Results: Ceramic surface treatment with Silano-Pen after sandblasting improved the bond strength of Superbond C&B resin cement. Supevbond C& B resin cement at Silano-Pen aiker sandblasting($27.4{\pm}3.8MPa$) showed statistically higher shear bond strength than the others. Conclusion: Within the limitation of this study, Superbond C& &B resin cement are suitable for cementation of zirconia ceramics and flame-treated with the Silano-Pen after sandblasting is required to enhance the bond strength.

Chilodonella hexasticha(Protozoa, Ciliata) from Korean freshwater fish (한국산 담수 어류에 기생하는 Chilodonella hexaticha에 관하여)

  • Ji, Bo-Young;Kim, Ki-Hong;Park, Soo-Il
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.113-118
    • /
    • 1996
  • During a study to document more fully the parasitic ciliates of Korean freshwater fishes, we found numerous small ciliates in the gills and skin of crucian carp, Carassius carassius. Cursory examination indicated that the ciliate were very similar with Chilodonella sp. In this study, we described the morphometrics of this ciliate in detail and compared with other species of Chilodonella in the world. Numerous small ciliates were observed in the body surface, fins and gills of infected fish and excessive mucus production were seen in those fish. Sometimes ulcer was observed in the body of moribund fish. From the scrutinized observation of the parasite, it was identified as Chilodonella hexasticha. The parasite was dorsoventrally flattened body, without a notch in the posterior margin, and it measured 30-$45{\mu}m$ long and 15-$30{\mu}m$ wide. In number of kineties, the right band ciliature was 3-5 and the left band ciliature was 3-5. The right ventral ciliary band shaped arch and was longer than the left, straight band. It had a single oval macronucleus, 8-$15{\mu}m$ in diameter, a single micronucleus, 2-$4{\mu}m$ in diameter. The cytopharynx was reinforced by 10-16 conspicuous nematodesmata, which shaped like a tube and curved at its inner end. Two contractile vacuoles, one anteriorly at right and the second posteriorly at left were observed in wet mounts. This parasite reproduced by a simple division at $22{\pm}1^{\circ}C$.

  • PDF

Finite Element Analysis on the Strength Safety of a Fuel Tank for Highly Compressed Gas Vehicle (수술실 내의 아산화질소($N_2O$) 노출평가)

  • Baek, Jong-Bae;Uhm, Min-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.34-38
    • /
    • 2009
  • Nitrous oxide, which is used as an anesthetic gas, has been shown to be a chronic health hazard. It is necessary to monitor and control the nitrous oxide exposure of the operating theaters staff. In this study, N2O exposure level of the operating nurses is assessed with a GC-ECD. The nitrous oxide gas is collected on a molecular sieve 5A contained in a glass tube and desorbed for 12 hours at $100^{\circ}C$ in heating block. As a result of the test using GC-ECD, calibration curve's $R^2$ of $N_2O$ is 0.9992, LOD is $0.96{\mu}g$/injection, LOQ is $3.21{\mu}g$/injection, desorption efficiency is 94.78 4.50% in average and break through is within 10% compared with the concentration. The average concentration before operation is 5.12ppm and it is 42.3ppm during operation. There are a significant difference showing that the P value is lower than 0.05. Assessing exposure level to nitrous oxide based on nurses' working positions, the exposure levels do not show significant difference( P>0.005). And $N_2O$ in active sampling method is higher than passive sampling method(P<0.05).

  • PDF

A Study on the Image Quality of Mammography and the Average Glandular Dose (맘모그래피의 화질과 평균유선조직선량에 관한 검토)

  • Lee, In-Ja;Kim, Hak-Sung;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.47-55
    • /
    • 2002
  • We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospitals in Seoul. 1. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. 2. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospitals. The unit at the B hospital exceeded the allowable limit by ${\pm}0.15$. 3. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. 4. The image quality of breast phantom photography was affected by the screen/film system among the hospitals. 5. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured $0.26{\sim}1.39\;mGy$ less than ACR standard 3.0 mGy.

  • PDF

Effects of reducing inclusion rate of roughages by changing roughage sources and concentrate types on intake, growth, rumen fermentation characteristics, and blood parameters of Hanwoo growing cattle (Bos Taurus coreanae)

  • Jeon, Seoyoung;Jeong, Sinyong;Lee, Mingyung;Seo, Jakyeom;Kam, Dong Keun;Kim, Jeong Hoon;Park, Jaehwa;Seo, Seongwon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.11
    • /
    • pp.1705-1714
    • /
    • 2019
  • Objective: Reducing roughage feeding without negatively affecting rumen health is of interest in ruminant nutrition. We investigated the effects of roughage sources and concentrate types on growth performance, ruminal fermentation, and blood metabolite levels in growing cattle. Methods: In this 24-week trial, 24 Hanwoo cattle ($224{\pm}24.7kg$) were fed similar nitrous and energy levels of total mixed ration formulated using two kinds of roughage (timothy hay and ryegrass straw) and two types of concentrate mixes (high starch [HS] and high fiber [HF]). The treatments were arranged in a $2{\times}2$ factorial, consisting of 32% timothy-68% HS, 24% timothy-76% HF, 24% ryegrass-76% HS, and 17% ryegrass-83% HF. Daily feed intakes were measured. Every four weeks, blood were sampled, and body weight was measured before morning feeding. Every eight weeks, rumen fluid was collected using a stomach tube over five consecutive days. Results: The mean dry matter intake (7.33 kg) and average daily gain (1,033 g) did not differ among treatments. However, significant interactions between roughage source and concentrate type were observed for the rumen and blood parameters (p<0.05). Total volatile fatty acid concentration was highest (p<0.05) in timothy-HF-fed calves. With ryegrass as the roughage source, decreasing the roughage inclusion rate increased the molar proportion of propionate and decreased the acetate-to-propionate ratio; the opposite was observed with timothy as the roughage source. Similarly, the effects of concentrate types on plasma total protein, alanine transaminase, Ca, inorganic P, total cholesterol, triglycerides, and creatinine concentrations differed with roughage source (p<0.05). Conclusion: Decreasing the dietary roughage inclusion rate by replacing forage neutral detergent fiber with that from non-roughage fiber source might be a feasible feeding practice in growing cattle. A combination of low-quality roughage with a high fiber concentrate might be economically beneficial.

Clinical Analysis of Disease Recurrence for the Patients with Secondary Spontaneous Pneumothorax (이차성 자연기흉 환자의 재발양상에 관한 분석)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Park, Seong-Sik;Ryu, Jae-Wook;Kim, Hyun-Jung
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.619-624
    • /
    • 2008
  • Background: Secondary spontaneous pneumothorax is caused by various underlying lung diseases, and this is despite that primary spontaneous pneumotherax is caused by rupture of subpleural blebs. The treatment algorithm for secondary pneumothorax is different from that for primary pneumothorax. We studied the recurrence rate, the characteristics of recurrence and the treatment outcomes of the patients with secondary spontaneous pneumothorax. Material and Method: Between March 2005 to March 2007, 85 patients were treated for their first episodes of secondary spontaneous pneumothorax. We analyzed the characteristics and factors for recurrence of secondary spontaneous pneumothorax by conducting a retrospective review of the medical records. Result: The most common underlying lung disease was pulmonary tuberculosis (49.4%), and the second was chronic obstructive lung disease (27.6%), The recurrence rate was 47.1% (40/85). The second and third recurrence rates were 10.9% and 3.5%, respectively. The mean follow up period was $21.1{\pm}6.7$ months (range: $0{\sim}36$ month). For the recurrence cases, 70.5% of them occurred within a year after the first episode. The success rates according to the treatment modalities were thoracostomy 47.6%, chemical pleurodesis 74.4%, blob resection 71% and Heimlich valve application 50%. Chemical pleurodesis through the chest tube was the most effective method of treatment. The factor that was most predictive of recurrence was 'an air-leak of 7 days or more' at the first episode. (p=0.002) Conclusion: The patients who have a prolonged air-leak at the first episode of pneumothorax tend to have a higher incidence of recurrence. Further studies with more patients are necessary to determine the standard treatment protocol for secondary spontaneous pneumothorax.

Clinical Use and Complications of Percutaneous Central Venous Catheterization in Very Low Birth Weight Infants (극소 저출생 체중아에서 경피 중심정맥 도관의 유용성과 합병증)

  • Kim, Hyang;Kim, Sun Hui;Byun, Hyung Suck;Choi, Young Youn
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.953-959
    • /
    • 2005
  • Purpose : The administration of total parenteral nutrition(TPN) has become a standard procedure in the management of nutritionally deprived and critically low birth weight neonates. Sepsis remains the most frequent serious complication during TPN, resulting in increased morbidity, mortality and health care costs. This study was performed to evaluate the clinical efficacy and complications of percutaneous central venous catheterization(PCVC) in very low birth weight infants. Methods : A total of 56 very low birth weight infants below 1,500 g during the period from January 1998 to December 2003 were enrolled and their medical records reviewed. Study group(n=32) included the babies who had undergone PCVC and a control group(n=24) included babies who had not undergone PCVC. We compared the study group with the control group for factors such as subject characteristics and catheter-related complications. Results : There was no difference in subject characteristics, such as birth weight, gestational week, respiratory distress syndrome, duration of ventilator therapy, duration from tube to complete oral feeding, days at TPN and its total duration, body weight at discontinuation of TPN and the days taken to reach to 2,000 g. However, the morbidity rate due to patent ductus arterious, chronic lung disease, necrotizing enterocolitis, osteopenia, cholestasis, and sepsis showed no difference. The study group with infants below 1,000 g showed a higher incidence of sepsis compared to the control group of the same weight group. The study group with infants between 1,000 to 1,500 g showed significantly higher incidences of intraventricular hemorrhage and took longer reach the a body weight of 2,000 g. Conclusion : Considering the high incidence of sepsis in the PCVC group, every attempt should be made to minimize the length of TPN therapy and encourage early enteral feeding. We also recommend the use of PCVC carefully in patients requiring prolonged nutritional support.

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF