• Title/Summary/Keyword: PM Point

Search Result 1,374, Processing Time 0.033 seconds

Binocular Vision Corrective Spectacle Lenses Reduce Visual Fatigue in 3-D Television Viewing (양안시 교정안경의 3차원 텔레비전 시청 중 발생한 안정피로 감소)

  • Yoon, Jeong Ho;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.363-369
    • /
    • 2014
  • Purpose: Three-dimensional (3D) displays are very useful in many fields, but induce physical discomforts in some people. This study is to assess symptom type and severity of asthenopia with their habitual distance corrective spectacle (HDCS) and their binocular vision corrective spectacle lenses (BVCSL) in people who feel physical discomforts. Methods: 35 adult subjects (ages $32.2{\pm}4.4$ yrs) were pre-screened out of 98 individuals to have the highest symptom/asthenopia scores following 65 minutes of 3D television viewing with HDCS. These 35 individuals were then retested symptom/asthenopia scores during they watched 3D television for 65 minutes at a distance of 2.7 m with wearing BVCSL of horizontal, vertical or base down yoked prisms. A 4-point symptom-rating scale questionnaire (0=no symptom and 3=severe) was used to assess 11 symptoms (e.g., blur, diplopia, etc.) related to visual fatigue/visual discomfort. Distance and near lateral phoria were measured using Howell phoria card and vertical phoria were measured using Maddox rod. Symptoms induced by watching 3D TV were compared between wearing HDCS and BVCSL. Results: Asthenopia in watching 3D TV with wearing BVCS was significantly lower than wearing HDCS at 5, 25, 45, and 65 minutes (all p < 0.001, paired t-tests). In only refractive error power correction power group, all asthenopia was not significantly different between HDCS and BVCSL (all $p{\geq}0.05$, paired t-tests). In prism correction groups for binocular imbalance, symptoms of asthenopia, however, was significantly lower for when wearing BVCSL than when wearing HDCS (all p < 0.05). Conclusions: Correction of phoria/vergence-based binocular vision imbalance can reduce asthenopia during 3D television viewing. An individual with binocular vision imbalance need corrected/compensated glasses with appropriate prisms prior to prolonged viewing of 3D television displays to reduce asthenopia/visual fatigue.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Learning Curve of a Laparoscopy Assisted Distal Gastrectomy for a Surgeon Expert in Performing a Conventional Open Gastrectomy (개복 위절제술에 경험이 풍부한 술자에 의한 복강경 보조하 원위부 위절제술의 Learning Curve)

  • Kim, Ji-Hoon;Jung, Young-Soo;Jung, Oh;Lim, Jeong-Taek;Yook, Jeong-Hwan;Oh, Sung-Tae;Park, Kun-Choon;Kim, Byung-Sik
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.167-172
    • /
    • 2006
  • Purpose: The laparoscopy assisted gastrectomy has been increasingly reported as the treatment of choice for early gastric cancer. However, expert surgeons, who have performed a conventional open gastrectomy for a long time, tend to have a negative attitude toward laparoscopic procedures. The aim of this study was to determine the learning curve of a laparoscopy assisted distal gastrectomy (LADG) for a surgeon expert in performing an open gastrectomy and to analyze the factors that have an effect on a LADG. Materials and Methods: Between April 2005 and March 2006, 62 patients underwent a LADG with D1+beta lymph-node dissection. The 62 patients were divided into 10 sequential groups with 6 cases in each group (the last group was 8 cases), and the time required to reach the plateau of the learning curve was determined by examining the average operative times of these 10 groups. Other factors, such as sex, BMI, complications, transfusion requirements, the number of retrieved lymph nodes, and change of postoperative hemoglobin level, were also analyzed. Results: With the $5^{th}$ group (after 30 cases), the operative time reached a plateau (average: 170 min/operation). The differences between before the $30^{th}$ case and after the $31^{st}$ case with respect to changes in the postoperative hemoglobin level, the number of retrieved lymph nodes, the transfusion requirements, and the complications rate were not significant. Conclusion: According to an analysis of the operative time, experience with 30 LADGs in patients with early gastric cancer is the point at which the plateau of the learning curve (7 months) is reached. Abundant experience with a conventional open gastrectomy and a well-organized laparoscopic surgery team are important factors in overcoming the learning curie earlier.

  • PDF

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

Storage condition that induce black heart of potato (Solanum tuberosom L.)

  • Jin, Yong-Ik;Chang, Dong-Chil;Cho, Ji-Hong;Yu, Dong-Lim;Nam, Jeong-Hwan;Yu, Hong-Seob;Koo, Bon-Choel;Choi, Jong-Kun;Lee, Soon-Ae
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.193-193
    • /
    • 2017
  • The black heart in potato is a physiological disorder that occurs when potatoes suffer from breathing problems. When storing potatoes at a low temperature around $0^{\circ}C$, there is a high possibility that the respiration rate of potato will rise and black heart will occur. Also, respiration can occur easily and briefly in a state where high temperature and ventilation is insufficient. Recently, as black heart has been occurred continuously and severely in South Korea, here we tried to identify the causes of black heart in potato and to develop the control strategy of this disorder. Firstly, we analyzed the influence on the black heart on the basis of preservation containers (breathable plastic box, burlap bag, paper box, sealed plastic box). After harvesting the potato which is cv. Superior, it preserved for 6 months under conditions of temperature $3.5^{\circ}C{\pm}0.2$ and humidity 85%, after then we surveyed the incidence of emergence rate, rate of weight loss and occurrence rate of black heart. Secondly, in order to investigate the time point of black heart initiation under the oxygen concentration condition of 1% or less, The potatoes were used for this experiment stored for 6 months in a aerated plastic box under conditions of temperature $3.5^{\circ}C{\pm}0.2$ and humidity 85% under sufficient oxygen condition. After stored for 6 month, those were stored at $15^{\circ}C$ and below 1% of oxygen for 25 days, and then the incidence of black heart was surveyed. Thirdly, to investigate the effects of the number of days after harvest on the occurrence of black heart, it was examined the occurrence of black heart stored on 40 days and 100 days after harvesting under sealed condition and vacuum condition. The temperature condition of potato storage was stored was at $4^{\circ}C$ and $25^{\circ}C$ in humidity 85%. As a result of investigating the occurrence of black heart depending on the storage containers, all of the potatoes stored in the sealed plastic box had been occurred black heart. However, black heart of the potatoes in the other treatments did not. Potato preserved under the condition of below 1% of oxygen was found to occur 32% black heart after 25 days of storage. The potatoes corresponding to the required number of days after harvesting were stored for 31 days and the black heart was examined on the occurred. As a result, the potatoes which were 40 days after the harvest did not have black heart under sealed condition and vacuum condition. But potatoes harvested 100 days after harvesting had a black heart incidence of 95.7% under sealed condition at $4^{\circ}C$. The potato placed in the vacuum condition and a sealed state at $25^{\circ}C$ was transformed into anaerobic respiration, the inner tissue of tuber collapsed. Therefore, it is considered that black heart is caused by the breathing trouble in the central part when the oxygen is almost consumed after the aerobic respiration which gradually consumes the oxygen. We conclude that the black heart occurred in the central part where exchange of oxygen and carbon dioxide is the slowest is sensitive to respiration disorder. It is thought that research to investigate black heart generation time according to storage conditions and post-harvest state of potatoes is further necessary.

  • PDF

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF