• Title/Summary/Keyword: PLC communication

Search Result 441, Processing Time 0.034 seconds

Protocol Design in Distribution Powerline Communication Network (배전선로를 이용한 통신망 구성 및 통신 프로토콜 설계)

  • Ju Seong-Ho;Gwak Kwi-Yil;Lim Yong-Hun;Park Byung-Seok;Kim Young-Hyun;Lee Beom-Seok;Hyun Duck-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.475-477
    • /
    • 2006
  • 최근들어 PLC 기술의 성능 및 안정성이 보완됨에 따라 배전선로 및 설비 감시를 위한 기존의 통신방식을 대체할 수 있게 되면서 PLC를 이용한 배전선로 통신망을 구성하는 연구가 활발히 진행중에 있다. 본 논문에서는 고속PLC를 이용하여 배전통신망을 구성할 경우 원활한 시스템을 구성하기 위한 Flooding 방지 프로토콜을 제안하고 시뮬레이션을 통해 고속 PLC망의 성능을 분석하고자 한다.

  • PDF

A Study on 8- Axis Servo Sync Control method and Implementation Using PLC Position Control Module (PLC에 의한 8축 동기제어의 구현)

  • Kim, S.W.;Kim, J.S.;Ryou, J.S.;Lee, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.880-882
    • /
    • 1995
  • The systematic function of the PLC (Programmable - Logic Controller) has been enhanced immensely due to the various special modules that consist of the conventional I/O control contants plus special function, which enables the flexible application to highly advanced systems. Position control module is one of the various PLC special module. In this paper, we proposed new synchronized operating method and implemented 8 - axis servo control system. The validity of proposed method is verified througth experimental results and it will be possible to expand 32 - axis servo control system by RS - 485 communication spec.

  • PDF

Authentication Mechanism for Power Line Communication System (전력선 통신 시스템을 위한 인증 메커니즘)

  • Heo, Joon;Hong, Choong-Seon;Ju, Sung-Ho;Lim, Yong-Hun;Lee, Bum-Suk;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1189-1190
    • /
    • 2007
  • 지금까지 국내 PLC 기술의 경우 그룹식별자(GID)를 키로 사용하는 암호화/복호화를 통해 보안 기능을 제공하고 있다. 그러나, 이러한 방법의 경우 동일한 셀(Cell)에 존재하는 PLC장비들이 동일한 키를 사용하게 된다. 따라서, 공격자는 GID를 획득함으로써 동일한 셀에 존재하는 모든 장비들의 정보를 획득하거나 조작할 수 있다. 이러한 문제가 발생하는 가장 큰 원인은 두 가지로 정리할 수 있다. 첫째, PLC 장비간 인증절차를 거치지 않는 것이다. 둘째, 단순 식별자를 암호화를 위한 보안키로 사용한다는 것이다. 따라서 본 논문은 한국산업규격(KSX 4600-1)의 매체접근제어(MAC)계층에서 정의하고 있는 기술을 근거로 PLC 장비간 인증 및 보안키 생성 메커니즘을 제안하고, 그에 따른 프레임 형식 및 동작과정을 제안한다.

  • PDF

Analysis of Characteristics of Residential Distribution Line for PLC Modem Design (PLC 모뎀설계를 위한 옥내 배선 특성분석)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1524-1526
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper and Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and the averaged analysis data are shown in the tables. The measured results no different from the calculated values with using conventional formula due to the line arrangement neglected factors, complex permittivity, and etc. Also, this paper describes many kinds of lines and wiring figures of domestic construction. Finally, it is utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

  • PDF

Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 임피던스 특성)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.67-78
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power line for power line communication (PLC) is analyzed. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the equivalent model and basic transmission line theory, input impedance at the signal induction part is calculated. And also calculated input impedance of power line itself that the medium voltage coupler and coaxial cable effect are removed. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power line itself is between $200\;{\Omega}\;and\;300\;{\Omega}$ and converges to a half of their characteristic impedance with increasing frequency. And also measured data is very similar to calculated data.

High Speed PLC-based Automatic Control System for a Smart LED Streetlight (스마트 LED 가로등을 위한 고속 전력선 통신 기반 자동제어 시스템)

  • Kim, Young-Suk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.95-102
    • /
    • 2014
  • In this paper, we propose the high speed PLC-based automatic control system for a smart LED streetlight. The proposed the automatic control system were constructed of a power line modem part and monitoring part, streetlight controller part for the high speed communication frequency band and streetlight ballasts characterization and real-time remote control using a high-speed PLC network, and it was designed to meet to lighting grades conditions of KS road lighting standards. The proposed automatic control system were easy monitoring of the power consumption using PC through to the comparison result of the existing streetlight system. As a result, it was confirmed to the possibility of efficient operation for the real-time monitoring and maintenance by induction of reasonable power consumption through to the LED streetlight state checking and remote-control. In addition, we proved to improvement of expected effects for the power cost savings, the energy efficiency, and streetlight differentiation and advanced.

A Study on the Implementation of outdoor type Virtual Private Network Gateway for Smart Grid (Smart Grid를 위한 필드형 가상사설망(VPN) 게이트웨이의 구현)

  • Park, Jun-Young;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.4
    • /
    • pp.125-136
    • /
    • 2011
  • The vulnerabilities existed in Korean electricity control systems is unexposed because it is being operated in a closed network with superior security. The threat will become greater once the closed network develops into a smart grid environment with superior intelligence. Security will have a greater impact once each household will be connected to the power plant via the smart meter. This research focuses on stable data transfer in harsh external environment and whole-nation coverage network, and suggested standardized and optimized Virtual Private Network (VPN) Gateway architecture to support Power Line Communication (PLC). The functionality and stability of the prototype has been verified with field tests. For implementation of outdoor type VPN device for smart grid, we adopted PLC low voltage remote-meter-net for data communication. Also, IPSec type tunneling and ARIA algorithm based encryption of data collected by PLC low voltage remote meter is transmitted.

Implementation of a High Performance Notch Filter Algorithm for Power Line Communication System (전력선 통신 시스템을 위한 고성능 Notch Filter 알고리즘 구현)

  • Nam, Yun-Ho;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.159-166
    • /
    • 2010
  • As Power Line has been already installed over 60% of a residential area all over the world, Broadband Service has been possible using high-speed PLC(Power Line Communication) without new access line installed for Internet access. Because of such reason, PLC is researched as the most suitable service for Last Mile Solution. But, Power Line is designed for transmitting electric power, so peripheral Wireless Communication System is affected by a leak of electric wave. In this paper, we propose a High Performance Notch Filter algorithm in comparison with a existing notch filter for reduction of interference between existing Wireless Communication Service and Power Line Service. In addition, we implement the Notch Filter emulator appling a High Performance Notch Filter and using a embedded board.

Integrated Network System of Milk Cow Stock-Farming Facilities for Stockbreeding Management (사양관리를 위한 젖소 목장 시설 통합 네트웍 시스템)

  • 김지홍;이수영;김용준;한병성;김동원
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.199-208
    • /
    • 2002
  • This paper introduces the method to make management network about milking cow farm tasks. The object of this research was to design of biological measuring system and managing network system in a livestock farm. This auto-management system provides informations about individual cows' temperature, conductivity of milk and weight for efficient management of feeding, and milking works by a micro-processor and RS -485 type serial COM. ports. And measured bio-data which are basic informations for remote raising management are saved to user PC by serial communication between the PLC and user PC. Milking cow farm is divided into three working place to each measurement work and feed. The first working place is milking station which has two thermometers, a conduct meter and a scale set. The second working place is feeding station, and the third place is cattle cage. These are combined by network system and the PLC which is used to drive network and sub-modules. Sub-modules have a micro-process to control the sensor and to interface with network. The PLC which drive network and control sequence has two serial communication port to be linked with user PC for sending the measured data and for receiving data. Above all, in this study tells the sequence operating method by the driving scenario of breeding milk cow for livestock auto-management using the PLC and network system.

  • PDF