• Title/Summary/Keyword: PLC(power line communication)

Search Result 278, Processing Time 0.027 seconds

PLC Filter Capacity Improvement and Efficiency Evaluation of Smart Street Lighting System (스마트 가로등 시스템의 전력선통신 필터 성능 개선 및 효율 평가)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.154-157
    • /
    • 2009
  • In order to give handiness to the management of the existing street lighting system which is based on the one way communication and to reduce the maintenance cost, the power line communication filter in the two way communication which is based on the CDMA communication and power line communication was improved and accordingly the stability of the communication performance was improved. Also, the efficiency of existing street lighting system and smart street lighting system was evaluated as Visual studio system. As a result, when the number of street lights is 10,000, the hours of daily work fell 50% and the number of necessary maintenance staff decreased 40%. Compared to the maintenance costs of the existing street lighting system, it could be expected to have the cut costs of almost 100 million won a year on the basis of 60 switch board and 1,200 street lights.

The Electric Power System Remote Control Of Semiconductor Plasma Manufacturing Equipment Using Power Line Communication (Power Line Communication을 이용한 반도체 Plasma 장비 전력시스템 원격제어)

  • Lee, Nae-Il;Kim, Jin-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1678-1679
    • /
    • 2007
  • This paper is the electric power system remote control of semiconductor plasma manufacturing equipment using PLC(power line communication). PLC is useful for economical data link but various problems and limitations are caused in using power lines for communications channel Develop of Semiconductor plasma manufactur ing equipment and remote automation technologies of tool develops day after day and standards. Also, Remote electric power control and device module control by GUIRCS(Graphic User Interface Remote Control System) of tool are monitoring in real time.

  • PDF

Modeling and Characterization of Low Voltage Access Network for Narrowband Powerline Communications

  • Masood, Bilal;Haider, Arsalan;Baig, Sobia
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.443-450
    • /
    • 2017
  • Nowadays, Power Line Communication (PLC) is gaining high attention from industry and electric supply companies for the services like demand response, demand side management and Advanced Metering Infrastructure (AMI). The reliable services to consumers using PLC can be provided by utilizing an efficient PLC channel for which sophisticated channel modeling is very important. This paper presents characterization of a Low Voltage (LV) access network for Narrowband Power Line Communications (NB-PLC) using transmission line (TL) theory and a Simulink model. The TL theory analysis not only includes the constant parameters but frequency selectivity is also introduced in these parameters such as resistance, conductance and impedances. However, the proposed Simulink channel model offers an analysis and characterization of capacitive coupler, network impedance and channel transfer function for NB-PLC. Analysis of analytical and simulated results shows a close agreement of the channel transfer function. In the absence of a standardized NBPLC channel model, this research work can prove significant in improving the efficiency and accuracy of NB-PLC communication transceivers for Smart Grid communications.

Implementation of a Dynamic High-performance Notch Filter applying CIC Filter Scheme (CIC Filter 기법을 적용한 동적 고성능 Notch Filter 구현)

  • Shin, Seong-Kyun;Jeong, Won-Ho;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.1-8
    • /
    • 2011
  • Power Line Communication (PLC: Power Line Communication) to propagate the current power lines are in every household of the existing infrastructure is the most extensive network configuration. In addition, the cost required for network configuration, the advantage of almost zero for the investors and is sufficient to attract the attention of operators. The PLC is supply power to power lines used the voice and data communication technologies put it on KHz ~ tens of hundreds of high-frequency signal MHz. But because uses power lines as existing wireless communications systems will occurs interference. The notch filters of a common way to eliminate the interference are used. In this paper, a dynamic high-performance notch filter applying CIC filter performance was verified through MATLAB and was implemented using a TI's TMS320C6416T DSP board.

Remote Dimming Control System Development of LED Street Light using PLC (전력선 통신을 이용한 LED 가로등의 원격조도제어 시스템 개발)

  • Kim, Ki-Nam;Yoo, Jin-Wan;Park, Jong-Yeon
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.113-118
    • /
    • 2010
  • In this paper, We proposed remote dimming control system for Light Emitting Diode(LED) street light using Power Line Communication(PLC). LED will be used widly by indoor or outdoor lighting because of semi-permanent life and environment restriction. For energy saving of street light, the dimming control system is very necessary and the PLC is a very efficient technique. Thus, in this paper we proposed the remote dimming control system for LED street light using PLC. A performance of the proposed system was validated by experimental results.

  • PDF

System Design of High-Definition Media Transceiver based on Power Line Communication and Its Performance Analysis (전력선 통신 기반 HD급 미디어 전송 시스템 설계 및 성능 분석)

  • Kim, Ji-Hyoung;Kim, Kwan-Woong;Kim, Yong-K.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.192-196
    • /
    • 2010
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. The strength of the PLC has no more additional wiring work. PLC has also possible to high quality data transmission with currently electrical cable. It has a various strong point campare with existing wire and wireless communication technologies. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. The video function was used for the VEDEO TEST GENERATOR in order to a property valuation. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal. It can be possible to have HD class Media service through the PLC.

Study on Very High-Rate Power Line Communications for Smart Grid (스마트그리드를 위한 초고속 전력선통신기술 연구)

  • Choi, Sung-Soo;Oh, Hui-Myoung;Kim, Young-Sun;Kim, Yong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1255-1260
    • /
    • 2011
  • In this paper, we study on the reliability of Very High-rate Power Line Communication (VH-PLC) for Smart Grid, so that the resultant data rate is over 400Mbps at a physical layer. Firstly, reviewing the research trend of the PLC, we discuss the required techniques for supporting the Smart Grid. Considering a pre-specification with the value of several parameters, we investigate a multi-carrier modulation technique to overcome limitations of higher rate transmission under power line channel environments. Then, we propose a system specification of the VH-PLC in the sense of enhancing two features. One is resolving the problem of the co-existence of the deployed high-speed PLC according to the published standardization of KS X 4600-1 in Korea. The other is getting better performance on the grid adopting the diverse element techniques, such as multi-carrier modulation, a subcarrier utilization mode, a variable rate LDPC (Low Density Parity Check) code, and a time and frequency diversity technique. Further, a simulation tool, composed of an Event-Driven simulator and a Time-Driven simulator, is developed for the purpose of verifying the system performance and continuously cross-checking the test bench signal of the proposed VH-PLC system.

Implement of Watt-Hour Meter Monitoring System by Internet Map Based GUI using Power Line Communication (전력선 통신을 이용한 인터넷 맵 연동 전자계량기 모니터링 시스템 구현)

  • Park, Keun-Soo;Lee, Young-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1435-1441
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system applying a Power Line Communication (PLC) MODEM and a Data Concentrator Unit (DCU) which can apply to Internet map based Graphical User Interface (GUI). The PLC MODEM is profitable by saving the cost of installing dedicated wiring, and Internet map GUI also is able to contribute an easy access to monitoring system for non export users. This system makes it possible to monitor the amount of electricity of previous/ current month metering data via Internet mapping service. The implement system can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.

Trends Research and Development View of Power Line Communication (전력통신을 위한 시장 동향 및 발전 전망)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.573-578
    • /
    • 2008
  • While going through economic development for several decades, Korea has become an industrialized country, and the development of industrial technology accelerated the advent of the information opportunity era. The recent information oriented society has brought forth the development of new information communication technology that enables anybody to obtain information easily and simply, and recently power line communication technology is being developed that allows the use of the existing power line net-works as they are. Each advanced country that faced up to a riffle effect of power line communication technology that enables us to obtain information easily anywhere at anytime is engaged in fierce competition to be a leader in this technology and to preoccupy the standardization of power line communication technology. At this point, this study is to help Korea take the lead in information communication technology by proposing a direction for the standardization that Korean power line communication technology needs to head for by identifying the trend of the worldwide of power line communication technology.

  • PDF

A study for chirp signal method & system implementation in the PLC modem with low speed (저속 PLC 모뎀에서의 Chirp 신호 방식과 시스템 구현에 관한 연구)

  • Jeong, Young-Hwa;Sang-Gun Lee
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.37-45
    • /
    • 2004
  • The representative communication method which is applied in the low-speed power line communication modem with 60bps is single carrier method. It has been used mainly for the control. The single carrier method is very sensitive to a power line communication channel environment. Specially, the severe attenuation of the transmission signal according to the notch characteristics of channel becomes the main cause of communication error. Domestic power line channel environment has this notable feature. In this paper, we implemented the low-speed power line communication system which used the chirp signal method to be strong in notch and noise characteristics. In this research, we proposed the method which transmits 1- '1 Unit symbol Chirp signal' with a 100${\mu}s$ time within 1ms for 1 bit. Also it applied for the Convolution code for an error correction and the Manchester code for a collision perception and an error detection. It used the method which uses the bit correlator for signal detection in the receiver parts. We confirmed that the communication method of the chirp method has a excellent performance compared to single carrier methods with a result of experiment of the low-speed power line communication system with the 60bps.

  • PDF