• 제목/요약/키워드: PISO algorithm

검색결과 42건 처리시간 0.027초

삼각봉을 지나는 층류유동에 대한 입구유동각도 변화의 영향 (EFFECTS OF INFLOW ANGLE ON LAMINAR FLOW PAST A TRIANGULAR CYLINDER)

  • 박태선
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.22-28
    • /
    • 2011
  • Laminar Flow over an equilateral triangular cylinder is studied for several inflow angles. Under an uniform flow of $Re_d$=50,75,100,125,150, the triangular cylinder is rotated by ${\theta}$=$0^{\circ}$,$15^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$,$75^{\circ}$,$90^{\circ}$,$105^{\circ}$. The governing equations are solved by the PISO algorithm based on the finite volume method of the unstructured grid system. The effects of the inflow angle on the vortex-shedding flows are investigated. The Strouhal number shows a minimum at ${\theta}$=$60^{\circ}$. It is closely related to the variation of pressure and flow structure induced by the movement of separation points.

리어가이더 시작각 변화가 횡류홴 성능에 미치는 영향 (Effects of Starting Angles of a Rearguider on the Performance of a Cross-Flow Fan)

  • 김형섭;김동원;윤태석;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1981-1986
    • /
    • 2004
  • A cross-flow fan relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there exists a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, it is difficult to analyze the reciprocal relations of the cross-flow fan because each parameter is independent. Numerical analyses are conducted with different starting angles of the rearguider. Two-dimensional, unsteady governing equations are solved, using FVM, PISO algorithm, sliding grid system and ${\kappa}-{\varepsilon}$ standard turbulence model.

  • PDF

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.

비압축성 점성 유동의 수치적 해석을 위한 사각형-삼각형 혼합 격자계 (Quadrilateral-Triangular Mixed Grid System for Numerical Analysis of Incompressible Viscous Flow)

  • 심은보;박종천;류하상
    • 한국CDE학회논문집
    • /
    • 제1권1호
    • /
    • pp.56-64
    • /
    • 1996
  • A quadrilateral-triangular mixed grid method for the solution of incompressible viscous flow is presented. The solution domain near the body surface is meshed using elliptic grid geneator to acculately simulate the viscous flow. On the other hand, we used unstructured triangular grid system generated by advancing front technique of a simple automatic grid generation algorithm in the rest of the computational domain. The present method thus is capable of not only handling complex geometries but providing accurate solutions near body surface. The numerical technique adopted here is PISO type finite element method which was developed by the present author. Investigations have been made of two-dimensional unsteady flow of Re=550 past a circular cylinder. In the case of use of the unstructured grid only, there exists a considerable amount of difference with the existing results in drag coefficient and vorticity at the cylinder surface; this may be because of the lack of the grid clustering to the surface that is a inevitable requirement to resolve the viscous flow. However, numerical results on the mixed grid show good agreements with the earlier computations and experimental data.

  • PDF

ANALYSES ON FLOW FIELDS AND PERFORMANCE OF A CROSS-FLOW FAN WITH VARIOUS SETTING ANGLES OF A STABILIZER

  • Kim D. W.;Kim H. S.;Park S. K.;Kim Youn J
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.107-112
    • /
    • 2005
  • A cross-flow fan is generally used on the region within the low static pressure difference and the high flow rate. It relatively makes high dynamic pressure at low rotating speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. At off-design points, there are a rapid pressure head reduction, a noise increase and an unsteady flow. Those phenomena are remarkably influenced by the setting angle of a stabilizer. Therefore, it should be considered how the setting angle of a stabilizer affects on the performance and the flow fields of a cross-flow fan. It is also required to investigate the effect of the volumetric flow rate before occurring stall. Two-dimensional, unsteady governing equations are solved using a commercial code, STAR-CD, which uses FVM. PISO algorithm, sliding grid system and standard k - ε turbulence model are also adopted. Pressure and velocity profiles with various setting angles are graphically depicted. Furthermore, the meridional velocity profiles around the impeller are plotted with different flow rates for a given rotating speed.

리어가이더 형상변화에 따른 횡류홴 성능해석 (Analysis of Performance of Cross-Flow Fan with Various Rear Guiders)

  • 김동원;이준환;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

축열 연소시스템의 최적화 구현을 위한 사용자 전용 해석 프로그램의 개발 (The Development of User Oriented CFD Program for Optimum Design of a Regenerative Combustion Furnace)

  • 강관구;유수열;유홍선;김혁주;노동순
    • 열처리공학회지
    • /
    • 제16권3호
    • /
    • pp.148-158
    • /
    • 2003
  • In this study, a user oriented CFD program for optimum design of a regenerative combustion furnace, REBURN was developed. For user's convenience, user friendly Graphic User Interface was made and the renumbering interface program was developed in order to directly input any generated mesh system from ICEM CFD/FEA. Also an automatic processing system for switching mode was developed. The program was verified through compahng with commercial CFD code about regenerative combustion furnace. Then, numerical simulation of real walking beam furnace used in real industry was performed and the parametric analysis was studied about the arrangement mode. As a results, the uniform temperature was appeared in the cross mode.

PSR-Based Microstructural Modeling for Turbulent Combustion Processes and Pollutant Formation in Double Swirler Combustors

  • Kim, Yong-Mo;Kim, Seong-Ku;Kang, Sung-Mo;Sohn, Jeong-Lak
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.88-97
    • /
    • 2001
  • The present study numerically investigates the fuel-air mixing characteristics, flame structure, and pollutant emission inside a double-swirler combustor. A PSR(Perfectly Stirred Reactor) based microstructural model is employed to account for the effects of finite rate chemistry on the flame structure and NO formation. The turbulent combustion model is extended to nonadiabatic flame condition with radiation by introducing an enthalpy variable, and the radiative heat loss is calculated by a local, geometry-independent model. The effects of turbulent fluctuation are taken into account by the joint assumed PDFs. Numerical model is based on the non-orthogonal body-fitted coordinate system and the pressure/velocity coupling is handled by PISO algorithm in context with the finite volume formulation. The present PSR-based turbulent combustion model has been applied to analyze the highly intense turbulent nonpremixed flame field in the double swirler combustor. The detailed discussions were made for the flow structure, combustion effects on flow structure, flame structure, and emission characteristics in the highly intense turbulent swirling flame of the double swirler burner.

  • PDF

디젤기관 연료분무의 분열 현상에 대한 수치해석적 연구 (A Numerical Study on the Break-up of the Fuel Spray in Diesel Engine)

  • 양희천;최영기;유홍선
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.8-22
    • /
    • 1995
  • Three dimensional numerical study of non-evaporating and evaporating spray characteristics was performed in a quiescent and motoring condition of direct injection diesel engine. The calculation parameter was breakup model. The breakup models used were Reitz & Diwakar model and TAB model. The modified k-${\varepsilon}$ turbulence model considering the compressibility effect due to the compression and expansion of piston was used. The calculation results of the spray tip penetration and tip velocity using the TAB model showed similar trends comparing with the experimental data. Although the evaporation rate was not nearly affected with the breakup model at the higher injection pressure, in the low injection case, the evaporation rate result using the TAB model became higher than that of R&D model. The evaporation rate was increased with the injection pressure due to the vigorous interaction with the gas field.

  • PDF

스태빌라이져 위치 및 리어가이더 형상변화에 따른 횡류홴의 성능특성 연구 (Performance of a Cross-Flow Fan with Various Stabilizer Positions and Rearguider Shapes)

  • 김동원;김형섭;윤태석;박성관;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제7권4호
    • /
    • pp.7-15
    • /
    • 2004
  • The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. The purpose of this study is to research the reciprocal relation among each parameter. Experiments and numerical analyses are conducted on effects of a stabilizer and a rearguider on performance analysis of a cross-flow fan. Two-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard $k-{\epsilon}$ turbulence model. Experiments are also carried out to estimate the performance of the modeled cross-flow fan. It is clarified that the rearguider of Archimedes type has excellent results for the most part.