• Title/Summary/Keyword: PFC converter

Search Result 391, Processing Time 0.032 seconds

Design of Electronic Ballast Reducing Acoustic Resonances Phenomina in Metal Halide Discharge Tube (메탈 할라이드 방전관 내의 음향 공명을 감소시킨 전자식 안정기 설계)

  • 김기정;박종연
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.405-412
    • /
    • 1999
  • Meta! Halide Discharge(]\1HD) Iamps have good color rendition, long life and good focusing capability but h have flickers bv acoustic resonances. We have designed the electronic ballast for reducing acoustic resonances in high pressure discharge tube. The ballast consists of main two parts, the first part is a half-bridge inverter to make a square wave form a and the st'Cond part is a flyback converter to combine the low frequency and high frequency component. As a r result of this study, we conclude that MHD lamps of 70 watt 따c very well light(D without acoustic resonance p phenomena by the elestronic ballast.

  • PDF

2MHz, 2kW RF Generator (2MHz, 2kW RF 전원장치)

  • Lee J.H.;Choi D.K.;Choi S.D.;Choi H.Y.;Won C,Y.;Kim S.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.260-263
    • /
    • 2003
  • When ICP(Inductive Coupled Plasma type etching and wafer manufacturing is being processed in semiconductor process, a noxious gas in PFC and CFC system is generated. Gas cleaning dry scrubber is to remove this noxious gas. This paper describes a power source device, 2MHz switching frequency class 2kW RF Generator, used as a main power source of the gas cleaning dry scrubber. The power stage of DC/DC converter is consist of full bridge type converter with 100kHz switching frequency Power amplifier is push pull type inverter with 2MHz switching frequency, and transmission line transformer. The adequacy of the circuit type and the reliability of generating plasma in various load conditions are verified through 50$\Omega$ dummy load and chamber experiments result.

  • PDF

A Study on Characteristic Analysis of High Frequency Generating Circuit Integrated Chopper-Inverter with High Power-Factor (고역률 초퍼-인버터 일체형 고주파 발생회로의 특성해석에 관한 연구)

  • Won Jae-Sun;Park Jae-Wook;Nam Seung-Sik;Lee Bong-Seob;Seok Jul-Ki;Kim Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.10
    • /
    • pp.610-617
    • /
    • 2004
  • This paper presents a novel high frequency generating circuit integrated chopper-inverter using ZVS with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant inverter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications. fluorescent lamp and DC-DC converter etc.

Reverse Recovery Current Suppression Power Factor Correction Circuit (역회복 전류억제 역률개선 회로)

  • Jang, Duk-Kyu;Shin, Yong-Hee;Kim, Chan-Sun;Park, Gwi-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.942-943
    • /
    • 2008
  • The boost converter is usually used in power factor correction. The dynamic losses of its output diode are produced during the reverse recovery time. The power efficiency is decreased due to the losses and also it generates the noise. These disadvantages have been remarkably improved by ZCS and ZVS techniques of power factor improvement circuit. Some benefits lead to the achievement of higher power density and the development cost can be decreased. In this paper work, the reverse recovery suppression(RS) PFC method is used. A inductor and a diode are added into the conventional circuit. The switching device, MOSFET is turned off after the reverse recovery current has come to the zero level. The Zero Current Switching(ZCS) is implemented at that time. This power conversion technique improves the efficiency to about 1% and reduces the noise obviously. And the additional inductor can be designed using an original filter core in the circuit. The converter size is reduced effectively.

  • PDF

Development of an Electronic Ballast for 70W Ceramic Discharge Metal Halide Lamps with Step Down Converter (강압형 컨버터를 이용한 70W CDM 램프용 전자식 안정기의 개발)

  • 김일권;길경석;김진모
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.435-439
    • /
    • 2002
  • This paper describes a design and fabrication of an electronic ballast for 70[W] ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active power factor correction circuit (PFC), a half-bridge inverter, a LC resonant circuit and a microprocessor. The developed ballast also includes a specially designed time circuit which provides reignition of lamps. Running frequency of the ballast is set at 40[kHz] to avoid acoustic-resonance and flickering. From the experimental results, input power factor and efficiency of the ballast are estimated 99.8[%] and 93.1[%)] respectively.

  • PDF

Characteristic Estimation of Single-Stage Active-Clamp Type High Frequency Resonant Inverter (단일 전력단 능동 클램프형 고주파 공진 인버터의 특성 평가)

  • 원재선;강진욱;김동희
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.2
    • /
    • pp.114-122
    • /
    • 2004
  • This paper presents a novel single-stage active-clamp type high frequency resonant inverter. The proposed topology is integrated full-bridge boost rectifier as power factor corrector and active-clamp type high frequency resonant inverter into a single-stage. The input stage of the full-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. By adding additional active-clamp circuit to conventional class-E high frequency resonant inverter, main switch of inverter part operates not only at Zero-Voltage-Switching mode but also reduces the switching voltage stress of main switch. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics estimation through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in the fields of induction heating applications, fluorescent lamp and DC-DC converter etc.

A Single-Switch AC-DC LED Driver Based on a Boost-Flyback PFC Converter with Lossless Snubber (무손실 스너버를 갖는 부스트-플라이백 역률보상 컨버터 기반의 단일 스위치 AC-DC LED 드라이버)

  • Lee, Sin Woo;Do, Hyun Lark
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.135-136
    • /
    • 2016
  • 본 논문은 무손실 스너버를 갖는 부스트-플라이백 역률보상 컨버터 기반의 단일 스위치 AC-DC LED(Light Emitting Diode) 드라이버를 제안한다. 제안된 LED 드라이버는 높은 역률을 얻기 위한 부스트 역률 개선 회로와 전기적 절연을 위한 무손실 스너버를 갖는 DC-DC 플라이백 모듈로 구성된다. 무손실 스너버에 의해 스위치의 서지 전압 스트레스는 감소하며 누설 인덕터의 에너지가 DC 링크 커패시터에 저장되어 재사용된다. 또한 낮은 정격 전압의 DC 링크 커패시터를 사용할 수 있다. 제안된 컨버터는 이론적 해석과 100[W]급 하드웨어 시작품을 제작하여 검증하였다.

  • PDF

A Study on the Power Factor Improvement of Single-Phase Bridgeless Voltage Doubler Converter (단상 브리지리스 배전압 변환기의 역률 개선에 관한 연구)

  • Koo, Do-Yeon;Kim, Dong-Wook;Lim, Seung-Beom;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.169-170
    • /
    • 2011
  • PFC(Power Factor Correction) converters are commonly designed for CCM(Continuous Conduction Mode). However, DCM(Discontinuous Conduction Mode) appears in the input current near the ZCP(Zero Crossing Point) at light loads, resulting in input current distortion. It is caused by inaccurate average current values obtained in DCM. This paper studies a simple digital control scheme that can be operated in both CCM and DCM with minimal changes to the CCM average current control structure.

  • PDF

Power Factor Correction Circuit with a Soft-switched Boost Scheme (스위칭 손실을 최소화한 부스트 방식의 역률 개선 회로)

  • Lee, Hyo-Jae;Choi, Hyun-Chil
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.122-129
    • /
    • 2011
  • In this paper, a new power factor correction circuit(PFC) based on a soft-switched boost scheme is proposed. Except for some soft-switching transition intervals, it operates exactly like the conventional boost scheme. Thus the desirable features of both high efficiency and easy control can be obtained. The design guidelines are suggested to achieve high efficiency. To verify the superior performance of the proposed circuit, experiment and simulation is carried out.

Bridgeless Forward-Flyback PFC Converter (브리지리스 포워드-플라이백 역률 개선 회로)

  • Jang, Paul;Baek, Jongbok;Cho, Bohyung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.143-144
    • /
    • 2011
  • 브리지리스 역률 개선 회로는 브리지 정류단을 제거해서 전류 도통 경로에 존재하는 스위칭 소자의 개수를 최소화함으로 기존 역률 개선 회로 대비 효율 향상을 가능케 하는 기법이다. 본 논문에서는 새로운 토폴로지의 브리지리스 포워드-플라이백 역률 개선 회로를 제안한다. 제안된 회로는 포워드 컨버터와 플라이백 컨버터의 동작을 모두 이용함으로써 브리지 정류단 없이 효과적으로 역률을 개선할 수 있다. 또한 컨버터 입력과 출력 사이에 직류 접지가 분리되는 절연형 특성을 가지며, 변압기의 권선비에 따라 출력 전압을 조절할 수 있다. 제안된 회로의 성능은 모의 실험을 통해 검토한다.

  • PDF