• 제목/요약/키워드: PF/R

검색결과 123건 처리시간 0.026초

반응성 r.f. 스퍼터링에 의한 마이크로 박막 전지용 산화바나듐 박막의 제작 및 전기화학적 특성 평가 (Fabrication and electrochemical characterization of amorphous vanadium oxide thin films for thin film micro-battery by reactive r.f. sputtering)

  • 전은정;신영화;남상철;윤영수;조원일
    • 한국진공학회지
    • /
    • 제9권1호
    • /
    • pp.42-47
    • /
    • 2000
  • The amorphous vanadium oxide thin films for thin-film rechargeable lithium batteries were fabricated by r.f. reactive sputtering at room temperature. As the experimental parameter, oxygen partial pressure was varied during sputtering. At high oxygen partial pressures(>30%), the as-deposited films, constant current charge/discharge characteristics were carried out in 1M $LiPF_6$, EC:DMC+1:1 liquid electrolyte using lithium metal as anode. The specific capacity of amorphous $V_2O_5$ after 200cycles of operation at room temperature was higher compared to crystalline $V_2O_5$. The amorphous vanadium oxide thin film and crystalline film showed about 60$\mu$Ah/$\textrm{cm}^2\mu\textrm{m}$ and about 38$\mu$Ah/$\textrm{cm}^2\mu\textrm{m}$, respectively. These results suggest that the battery capacity of the thin film vanadium oxide cathode strongly depends on the crystallinity.

  • PDF

Electrolytes - Quality at Point of Use

  • Heider U.;Jungnitz M.;Oesten R.
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 1998년도 전지기술 심포지움
    • /
    • pp.153-166
    • /
    • 1998
  • Lithium ion Batteries commercially available since the early nineties in Japan are going to be more and more important for portable electronic devices and even EV applications. Today several companies around the world are working hard to join to market for Lithium secondary batteries. Based on the growing interest for commercial use of batteries also the materials have to be reviewed in order to meet large scale production needs. The requirements especially for electrolytes for lithium batteries are extremely high. The solvents and the lithium salts should be of highest purity. So the supply of these chemicals including packaging, transportation and storage but also the handling in production are critical items in this field. Frolic impurities are very critical for LiPF6 based electrolytes. The influence of water is tremendous. But also the other protic impurities like alcoholes are playing an Important role for the electrolyte quality. The reaction of these species with LiPF6 leads to formation of HF which further reacts with cathode materials (spinel) and anode. To understand the role of the protic impurities more clearly the electrolyte was doped with such compounds and was analyzed for protic impurities and HF. These results which directly show the relation between impurities and quality will be presented and discussed. In addition several investigations on different packaging materials as well as methods to analyze and handle the sensititive material will be addressed. These questions which are only partly discussed in literature so far and never been investigated systematically cover some of the key parameters for understanding of the battery chemicals. This investigation and understanding however is of major importance for scientist and engineers in the field of Lithium ion and Lithium polymer batteries.

  • PDF

Effect of Counter Anions on Solid Electrolyte Interphase Formation on Graphite Electrodes in Propylene Carbonate-based Electrolyte Solutions

  • Song, Hee-Youb;Kim, Seong In;Nogales, Paul Maldonado;Jeong, Soon-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권1호
    • /
    • pp.55-60
    • /
    • 2019
  • Herein, the effect of counter anions on the formation of a solid electrolyte interphase (SEI) in a propylene carbonate (PC)-based electrolyte solution was investigated. Although the reversible capacities were different, reversible intercalation and de-intercalation of lithium ions occurred in the graphite negative electrode in the PC-based electrolyte solutions containing 1 M $LiClO_4$, $LiPF_6$, $LiBF_4$, and $LiCF_3SO_3$ at low temperature ($-15^{\circ}C$). This indicated that the surface films acted as an effective SEI to suppress further co-intercalation and decomposition reactions at low temperature. However, the SEIs formed at the low temperature were unstable in 1 M $LiPF_6$ and $LiBF_4/PC$ at room temperature ($25^{\circ}C$). On the other hand, increasing reversible capacity was confirmed in the case of $LiCF_3SO_3/PC$ at room temperature, because the SEI formed at the low temperature was still maintained. These results suggest that counter anions are an important factor to consider for the formation of effective SEIs in PC-based electrolyte solutions.

등온증폭법을 이용한 Clostridium difficile 검출 (Detection of Clostridium difficile by Loop-Mediated Isothermal Amplification)

  • 인예원;하수정;양승국;오세욱
    • 한국식품영양과학회지
    • /
    • 제41권9호
    • /
    • pp.1326-1330
    • /
    • 2012
  • 본 연구는 loop-mediated isothermal amplification(LAMP)을 이용하여 Clostridium difficile을 검출하고자 하였다. LAMP 수행을 위하여 선택적인 타깃 유전자로 C. difficile의 16S ribosomal RNA를 타깃으로 하여 primer set를 구성하였다. 5개의 primer set(BIP, FIP, B3, F3, LF, PF)를 이용하여 TcdA와 TcdB toxin이 모두 양성인 균주, TcdA와 TcdB toxin이 모두 음성인 균주와 식품 분리균주를 효과적으로 검출할 수 있었다. LAMP는 80분 이내의 시간이 필요하며 thermocycler와 같은 장비를 필요로 하지 않고 또한 결과를 직접 눈으로 확인할 수 있기 때문에 식품 생산 현장에서 활용될 수 있을 것이라고 생각되었다.

TRPC-Mediated Current Is Not Involved in Endocannabinoid-Induced Short-Term Depression in Cerebellum

  • Chang, Won-Seok;Kim, Jun;Kim, Sang-Jeong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제16권2호
    • /
    • pp.139-144
    • /
    • 2012
  • It has been reported that activation of metabotropic glutamate receptor 1 (mGluR1) can mediate endocannabinoid-induced short-term depression of synaptic transmission in cerebellar parallel fiber (PF)-Purkinje cell (PC) synapse. mGluR1 has signaling pathways involved in intracellular calcium increase which may contribute to endocannabinoid release. Two major mGluR1-evoked calcium signaling pathways are known: (1) slow-kinetic inward current carried by transient receptor potential canonical (TRPC) channel which is permeable to $Ca^{2+}$; (2) $IP_3$-induced calcium release from intracellular calcium store. However, it is unclear how much each calcium source contributes to endocannabinoid signaling. Here, we investigated whether calcium influx through mGluR1-evoked TRPC channel contributes to endocannabinoid signaling in cerebellar Purkinje cells. At first, we applied SKF96365 to inhibit TRPC, which blocked endocannabinoid-induced short-term depression completely. However, an alternative TRP channel inhibitor, BTP2 did not affect endocannabinoid-induced short-term depression although it blocked mGluR1-evoked TRPC currents. Endocannabinoid signaling occurred normally even though the TRPC current was mostly blocked by BTP2. Our data imply that TRPC current does not play an important role in endocannabinoid signaling. We also suggest precaution in applying SKF96365 to inhibit TRP channels and propose BTP2 as an alternative TRPC inhibitor.

EC:MA 혼합전해질에서 카본 전극의 용량 특성 - I. 전기화학적 특성에 대한 혼합비의 영향 - (Properties of Capacity on Carbon Electrode in EC:MA Electrolytes - I. Effect of Mixing Ratio on the Electrochemical Properties -)

  • 박동원;김우성;손동언;김성필;최용국
    • 공업화학
    • /
    • 제17권2호
    • /
    • pp.183-187
    • /
    • 2006
  • 리튬-이온 전지에서 전해질 용액에 대한 용매의 선택은 충방전 특성의 개선을 위해 매우 중요하다. 여러 가지 용매 시스템이 리튬-이온 전지의 전해질로서 광범위하게 연구 되어졌다. 본 연구는 다양한 혼합비에서 제조한 1 M $LiPF_6/EC$ (ethylene carbonate) : MA (methyl acetate) (x:y) 전해질 용액의 용매 분해 전위와 카본 부극 표면에 형성된 Solid Electrolyte Interphase 피막의 전기화학적 성질을 시간대 전위법, 순환 전압- 전류법, 임피던스법을 이용하여 관찰하였다. 용매분해 전위는 전해질의 이온 전도도에 따라 전위가 달라졌고, 용매의 혼합비에 따라 피막의 전기화학적 특성이 변화되었음을 확인하였다. 결과적으로, 1 M $LiPF_6/(EC+MA)$ 시스템에서 가장 적절한 EC와 MA의 혼합비는 대략 1:3 (EC:MA, 부피비)이었다.

Translation and Validation of the Activities of Daily Living Scale with Iranian Elderly Cancer Patients Treated in an Oncology Unit

  • Khoei, Mahtab Alizadeh;Akbari, Mohammad Esmail;Sharifi, Farshad;Fakhrzadeh, Hossein;Larijani, Bagher
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.2731-2737
    • /
    • 2013
  • Background: This study evaluated the validity and reliability of applying the Katz's Activities of Daily Living (ADL) scale in an Iranian sample of elderly oncologic patients following initial cancer treatment. Materials and Methods: The scale was translated with the forward-backward procedure to give an Iranian version. The ADL scale was then applied in a random sample of 400 oncologic patients aged 60 and older following initial cancer treatment. Assessment of the scale stability was twice, with a 14-days (two weeks) interval, to 30 (of the 400) eligible elderly cancer patients in March 2012. To measure treatment effects, the index was run with 150 patients in a three month recall, following oncology processing. Exploratory and confirmatory factor analysis was performed for assessment of construct validity of the Katz's ADL. Reliability was measured with internal consistency (Cronbach's alpha co-efficient), and test/retest (Spearman's r value) of the instrument. Criterion validity was evaluated by comparing the Katz with Physical Function (PF) subscale of SF 36. Known-group validity was approved by comparing of Katz' ADL between quartile groups of PF subscale of SF 36. Results: In our study the ADL demonstrated a high degree of internal homogeneity (Cronbach's alpha 0.923). There was a high correlation between scores of two time measurement of Katz's ADL (p value of two- related- samples test was 0.3). Construct validity showed a correlation coefficient of 0.572 between the ADL and PF scores. In factor analysis, 2 factors were extracted. Evidence for the reliability of the questionnaire was good and known group validity was approved by significant differences of ADL score between quartiles of the PF subscale of SF36. Conclusions: The results suggest that the Iranian version of ADL applied for oncologic older adult patients following initial cancer treatment is a reliable and a valid clinical instrument and comparable to those reported in other studies.

Is Diabetes a Contraindication to Lower Extremity Flap Reconstruction? An Analysis of Threatened Lower Extremities in the NSQIP Database (2010-2020)

  • Amy Chen;Shannon R. Garvey;Nimish Saxena;Valeria P. Bustos;Emmeline Jia;Monica Morgenstern;Asha D. Nanda;Arriyan S. Dowlatshahi;Ryan P. Cauley
    • Archives of Plastic Surgery
    • /
    • 제51권2호
    • /
    • pp.234-250
    • /
    • 2024
  • Background The impact of diabetes on complication rates following free flap (FF), pedicled flap (PF), and amputation (AMP) procedures on the lower extremity (LE) is examined. Methods Patients who underwent LE PF, FF, and AMP procedures were identified from the 2010 to 2020 American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP®) database using Current Procedural Terminology and International Classification of Diseases-9/10 codes, excluding cases for non-LE pathologies. The cohort was divided into diabetics and nondiabetics. Univariate and adjusted multivariable logistic regression analyses were performed. Results Among 38,998 patients undergoing LE procedures, 58% were diabetic. Among diabetics, 95% underwent AMP, 5% underwent PF, and <1% underwent FF. Across all procedure types, noninsulin-dependent (NIDDM) and insulin-dependent diabetes mellitus (IDDM) were associated with significantly greater all-cause complication rates compared with absence of diabetes, and IDDM was generally higher risk than NIDDM. Among diabetics, complication rates were not significantly different across procedure types (IDDM: p = 0.5969; NIDDM: p = 0.1902). On adjusted subgroup analysis by diabetic status, flap procedures were not associated with higher odds of complications compared with amputation for IDDM and NIDDM patients. Length of stay > 30 days was statistically associated with IDDM, particularly those undergoing FF (AMP: 5%, PF: 7%, FF: 14%, p = 0.0004). Conclusion Our study highlights the importance of preoperative diabetic optimization prior to LE procedures. For diabetic patients, there were few significant differences in complication rates across procedure type, suggesting that diabetic patients are not at higher risk of complications when attempting limb salvage instead of amputation.

레진 시멘트와 상아질접착제를 사용한 콤포지트 레진 코아의 전단결합강도에 관한 연구 (SHEAR BOND STRENGTH OF COMPOSITE RESIN CORE USED IN COMBINATION WITH VARIOUS RESIN CEMENTS AND DENTIN BONDING AGENTS)

  • 김현오;방몽숙
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.30-40
    • /
    • 2004
  • Purpose : The purpose of this study was aimed to compare the shear bond strength on dentin of three dentin bonding agents and two resin cements used in conjunction with self-cured composite resin core material. Material and method : Control group and six experimental groups were divided for this study. Control group was designated as specimens bonded with Tenure$ A&B^{(R)}$. Experimental groups were as follows : PB-BL group : specimens bonded with Prime&Bond $NT^{(R)}$, $BondLink^{(R)}$ SB-BL group : specimens bonded with $^{(R)}$, BondLink$SingleBond^{(R)}$ PB group : specimens bonded with Prime&Bond $NT^{(R)}$ SB group : specimens bonded with $SingleBond^{(R)}$ PF group : specimens bonded with $Panavia-F^{(R)}$ BI group specimens bonded with Bistite $II^{(R)}$ All specimens were stored in $37^{\circ}C$ distilled water for 24 hours, followed by the shear bond strength was tested by universal testing machine. The data was analysed statistically by Mann-Whitney test. Results : 1. For Prime&Bond $NT^{(R)}$ and $SingleBonde^{(R)}$, the shear bond strength was 0.24 MPa and 7.19 MPa each by each, while Tenure $A&B^{(R)}$ group control was measured at 13.93 MPa (p<0.05). Especially for Prime&Bond $NT^{(R)}$ it did not get conjunction with dentin. 2. For Prime&Bond $NT^{(R)}$ and $SingleBond^{(R)}$ using $BondLink^{(R)}$, there was no significant difference as a result of 11.73 MPa and 14.00 MPa each by each (p<0.05). 3. For $Panavia-F^{(R)}$ and Bistite $II^{(R)}$, they showed the highest shear bond strength as measured by 18.24 MPa and 16.09 MPa each (p<0.05).

PF열교환기에서 R410A 냉매분배의 영향 (Analysis of R410A refrigerant distribution in parallel flow heat exchanger)

  • 김정식;김내현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2008
  • A computer program, which simulates the parall flow evaporator was developed. The program was having used to simulate the sample $650\;mm{\times}190\;mm$ frontal area, 25 mm flow depth and 3.0 mm fin pitch. It was shown that the cooling capacity of 3kW could be available from the sample. The present model, however, does not consider refrigerant mal-distribution in each pass, which is known to reduce the cooling capacity of the parallel flow heat exchanger.

  • PDF