• Title/Summary/Keyword: PDIP

Search Result 10, Processing Time 0.021 seconds

A Study on the Effects of Package and PCB Materials on Thermal Characteristics of PDIP (패키지 및 PCB 재료가 PDIP 열특성에 미치는 영향에 관한 연구)

  • 정일용;이규봉
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.729-737
    • /
    • 1994
  • A three-dimensional finite element model of a 20-pin plastic dual-in-line package(PDIP) plugged into a PCE has been developed by using the finite element code ANSYS. The model has been used for thermal characterization of the package during its normal operation under natural convection cooling. Temperature distributions in the package and PCB are obtained from numerical analysis and compared with experimentally measured data. Various cases are assumed and analyzed to study the effects of package and PCB materials on thermal characteristics of PDIP with and without aluminum heatspreader. Thermal dissipation capability of PDIP is greatly increased due to copper die pad/lead frame and heatspreader. However, thermally induced stresses in the package and fatigue life of chip are improved for PDIP with Alloy 42 die pad/lead frame and no heatspreader. It is also found that the role of PCB on thermal characteristics of PDIP is very imporatant.

Comparison Analysis of Patient Specific Quality Assurance Results using portal dose image prediction and Anisotropic analytical algorithm (Portal dose image prediction과 anisotropic analytical algorithm을 사용한 환자 특이적 정도관리 결과 비교 분석)

  • BEOMSEOK AHN;BOGYOUM KIM;JEHEE LEE
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.15-21
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the performance of the anisotropic analytical algorithm (AAA) and portal dose image prediction (PDIP) for patient-specific quality assurance based on electronic portal imaging device, and to evaluate the clinical feasibility of portal dosimetry using AAA. Subjects and methods: We retrospectively selected a total of 32 patients, including 15 lung cancer patients and 17 liver cancer patients. Verification plans were generated using PDIP and AAA. We obtained gamma passing rates by comparing the calculated distribution with the measured distribution and obtained MLC positional difference values. Results: The mean gamma passing rate for lung cancer patients was 99.5% ± 1.1% for 3%/3 mm using PDIP and 90.6% ± 5.8% for 1%/1 mm. Using AAA, the mean gamma passing rate was 98.9% ± 1.7% for 3%/3 mm and 87.8% ± 5.2% for 1%/1 mm. The mean gamma passing rate for liver cancer patients was 99.9% ± 0.3% for 3%/3 mm using PDIP and 96.6% ± 4.6% for 1%/1 mm. Using AAA, the mean gamma passing rate was 99.6% ± 0.5% for 3%/3 mm and 89.5% ± 6.4% for 1%/1 mm. The MLC positional difference was small at 0.013 mm ± 0.002 mm and showed no correlation with the gamma passing rate. Conclusion: The AAA algorithm can be clinically used as a portal dosimetry calculation algorithm for patientspecific quality assurance based on electronic portal imaging device.

  • PDF

A Study on Primal-Dual Interior-Point Method (PRIMAL-DUAL 내부점법에 관한 연구)

  • Seung-Won An
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.801-810
    • /
    • 2004
  • The Primal-Dual Interior-Point (PDIP) method is currently one of the fastest emerging topics in optimization. This method has become an effective solution algorithm for large scale nonlinear optimization problems. such as the electric Optimal Power Flow (OPF) and natural gas and electricity OPF. This study describes major theoretical developments of the PDIP method as well as practical issues related to implementation of the method. A simple quadratic problem with linear equality and inequality constraints

A New Approach to Solve the Rate Control Problem in Wired-cum-Wireless Networks

  • Loi Le Cong;Hwang Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1636-1648
    • /
    • 2006
  • In this paper, we propose a new optimization approach to the rate control problem in a wired-cum-wireless network. A primal-dual interior-point(PDIP) algorithm is used to find the solution of the rate optimization problem. We show a comparison between the dual-based(DB) algorithm and PDIP algorithm for solving the rate control problem in the wired-cum-wireless network. The PDIP algorithm performs much better than the DB algorithm. The PDIP can be considered as an attractive method to solve the rate control problem in network. We also present a numerical example and simulation to illustrate our conclusions.

  • PDF

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

Clinical implementation of PerFRACTIONTM for pre-treatment patient-specific quality assurance

  • Sang-Won Kang;Boram Lee;Changhoon Song;Keun-Yong Eeom;Bum-Sup Jang;In Ah Kim;Jae-Sung Kim;Jin-Beom Chung;Seonghee Kang;Woong Cho;Dong-Suk Shin;Jin-Young Kim;Minsoo Chun
    • Journal of the Korean Physical Society
    • /
    • v.80
    • /
    • pp.516-525
    • /
    • 2022
  • This study is to assess the clinical use of commercial PerFRACTIONTM for patient-specific quality assurance of volumetric-modulated arc therapy. Forty-six pretreatment verification plans for patients treated using a TrueBeam STx linear accelerator for lesions in various treatment sites such as brain, head and neck (H&N), prostate, and lung were included in this study. All pretreatment verification plans were generated using the Eclipse treatment planning system (TPS). Dose distributions obtained from electronic portal imaging device (EPID), ArcCHECKTM, and two-dimensional (2D)/three-dimensional (3D) PerFRACTIONTM were then compared with the dose distribution calculated from the Eclipse TPS. In addition, the correlation between the plan complexity (the modulation complexity score and the leaf travel modulation complexity score) and the gamma passing rates (GPRs) of each quality assurance (QA) system was evaluated by calculating Spearman's rank correlation coefficient (rs) with the corresponding p-values. The gamma passing rates of 46 patients analyzed with the 2D/3D PerFRACTIONTM using the 2%/2 mm and 3%/3 mm criteria showed almost similar trends to those analyzed with the Portal dose imaging prediction (PDIP) and ArcCHECKTM except for those analyzed with ArcCHECKTM using the 2%/2 mm criterion. Most of weak or moderate correlations between GPRs and plan complexity were observed for all QA systems. The trend of mean rs between GPRs using PDIP and 2D/3D PerFRACTIONTM for both criteria and plan complexity indices as in the GPRs analysis was significantly similar for brain, prostate, and lung cases with lower complexity compared to H&N case. Furthermore, the trend of mean rs for 2D/3D PerFRACTIONTM for H&N case with high complexity was similar to that of ArcCHECKTM and slightly lower correlation was observed than that of PDIP. This work showed that the performance of 2D/3D PerFRACTIONTM for pretreatment patient-specific QA was almost comparable to that of PDIP, although there was small difference from ArcCHECKTM for some cases. Thus, we found that the PerFRACTIONTM is a suitable QA system for pretreatment patient-specific QA in a variety of treatment sites.

Feasibility Study of Patient Specific Quality Assurance Using Transit Dosimetry Based on Measurement with an Electronic Portal Imaging Device

  • Baek, Tae Seong;Chung, Eun Ji;Son, Jaeman;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.54-60
    • /
    • 2017
  • This study was designed to measure transit dose with an electronic portal imaging device (EPID) in eight patients treated with intensity modulated radiotherapy (IMRT), and to verify the accuracy of dose delivery to patients. The calculated dose map of the treatment planning system (TPS) was compared with the EPID based dose measured on the same plane with a gamma index method. The plan for each patient was verified prior to treatment with a diode array (MapCHECK) and portal dose image prediction (PDIP). To simulate possible patient positioning errors during treatment, outcomes were evaluated after an anthropomorphic phantom was displaced 5 and 10 mm in various directions. Based on 3%/3 mm criteria, the $mean{\pm}SD$ passing rates of MapCHECK, PDIP (pre-treatment QA) for 47 IMRT were $99.8{\pm}0.1%$, $99.0{\pm}0.7%$, and, respectively. Besides, passing rates using transit dosimetry was $90.0{\pm}1.5%$ for the same condition. Setup errors of 5 and 10 mm reduced the mean passing rates by 1.3% and 3.0% (inferior to superior), 2.2% and 4.3% (superior to inferior), 5.9% and 10.9% (left to right), and 8.9% and 16.3% (right to left), respectively. These findings suggest that the transit dose-based IMRT verification method using EPID, in which the transit dose from patients is compared with the dose map calculated from the TPS, may be useful in verifying various errors including setup and/or patient positioning error, inhomogeneity and target motions.

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Islam, Authoritarian Legacy, and Income in the Continuity of Indonesia's Party System: Based on Urban Survey Data (인도네시아 정당체계의 연속성과 정치균열의 문제: 도시부문 설문조사를 바탕으로)

  • Choi, Jungug
    • The Southeast Asian review
    • /
    • v.23 no.3
    • /
    • pp.217-256
    • /
    • 2013
  • This study addresses the issue of the continuity in Indonesia's party system with respect to Islam, authoritarian legacy and income, using the urban-based individual face-to-face survey data. The existing studies focus on the historical continuity of the Indonesian party system between the 1955 and 1999 democratic elections. Yet, this study deals with the continuity and discontinuity between the pre-transitional 1997 election and the transitional 1999 election. It finds that the effect of Islam is largely independent of the democratic transition: Islam-oriented voters under the authoritarian rule tend to remain in the Islamic camp even during and after the democratic transition, while most of the secular voters prior to the democratic transition continue to shun any Islamic parties during the democratization. The effect of authoritarian legacy is also found to be meaningful, even if not as sticky as Islam. Finally, the variable of income is significant. Contrary to the popular belief, the PDIP is not a party of the urban poor but the PPP is the urban poor's favorite choice. This implies the linkage between poverty and political Islam.