Propagation Characteristics of Acoustic Signals Produced by Partial Discharge in Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Kim, Sung-Wook;Park, Chan-Yong;Park, Dae-Won;Kil, Gyung-Suk;Rhyu, Keel-Soo
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.841-847
    • /
    • 2009
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. To measure small acoustic signals produced by PD, we fabricated an amplifier and simulated PD at a needle-plane electrode system set in insulation oil. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz$\sim$1.6 MHz. These are enough characteristics for the measurement of acoustic signals. After a comparative calibration experiment by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil.

  • PDF

The signal interpretion of PD on DS for GIS (GIS 단로기의 부분방전 신호해석)

  • Kim, Jong-Seo;Park, Yong-Pil;Lee, Eun-Suk;Jeong, Seung-Cheon;Lim, Young-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.1-4
    • /
    • 2004
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this anslysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm.

  • PDF

The diagnosis of internal trouble on DS for GIS using PD detection (부분방전 검출을 이용한 GIS 단로기 내부이상 진단)

  • Kim, Jong-Seo;Lee, Eun-Suk;Cheon, Jong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.575-578
    • /
    • 2003
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this analysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

Identification of Void Diameters for Cast-Resin Transformers (몰드변압기의 보이드 결함 크기 판별)

  • Jeong, Gi-woo;Kim, Wook-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.570-573
    • /
    • 2022
  • This paper presents the identification of void diameters for a cast-resin transformer using an artificial neural network (ANN) model. A PD signal was measured by the Rogowski coil sensor which has the planar and thin structures fabricated on a printed circuit board (PCB), and the PD electrode system was fabricated to simulate a PD defect by a void. In addition, void samples with different diameters were fabricated by injecting air in a cylindrical aluminum frame using a syringe during the epoxy curing process. To identify the diameter of void defects, PD characteristics such as the discharge magnitude, pulse count, and phase angle were extracted and back propagation algorithm (BPA) was designed using virtual instrument (VI) based on the Labview program. From the experimental results, the BPA algorithm proposed in this paper has over 90% accurate rate to identify the diameter of void defects and is expected to use reference data of maintenance and replacement of insulation for cast-resin transformers in the on-site PD measurement.

  • PDF

Measures of modal and gross controllability/observability for linear time-varying systems (선형 시변 시스템에 대한 모드 및 총가제어성/가관측성 척도)

  • Choe, Jae-Won;Lee, Ho-Chul;Lee, Dal-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.6
    • /
    • pp.647-655
    • /
    • 1999
  • For linear time-varying systems described by the triple (A(t),B(t),C(t)) where A(t),B(t),C(t) are the system, the input, and the output matrices, respectively, we propose concepts for measures of modal and gross controllability /observability. We introduce a differential algebraic eigenbvalue theory for linear time-varying systems to calculate the PD-eigenvalues and left and right PD-eigenvectors of the system matrix A(t) which will be used to derive the concepts for the measures. The time-dependent angle between the left PD-eigenvectors of the system matrix A(t) and the columns of the input matrix B(t), and the magnitude of the each element of the input matrix B(t) are used to propose the modal controllability measure. Similarly, the time-dependent angle between the right PD-eigenvectors of the system matrix A(t) and the rows of the output matrix C(t) are used to propose the madal observability measure. Gross measure of controllability of a mode from all inputs and its gross measure of observability in all outputs for the linear time-varying systems are also proposed. Numerical examples are presented to illustrate the proposed concepts.

  • PDF

Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers (몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술)

  • Jung, Kwang-Seok;Park, Dae-Won;Cha, Hyeon-Kyu;Cha, Sang-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

Assessment of Insulation Condition in Gas Turbine Generator Stator Windings (가스터빈 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Yang, Gyu-Hyun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

Propagation Characteristics of Acoustic Signals Produced by Partial Discharges in an Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Park, Dae-Won;Cha, Sang-Wook;Cho, Hyang-Eun;Kim, Dong-Geon;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.188-188
    • /
    • 2011
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. We fabricated a decoupler and an amplifier to measure acoustic signals produced by PD. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz~1.6 MHz. After a comparative calibration by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil as a function of distance.

  • PDF

Anisotropy Coupling in Patterned Thin Films with Mixed Uniaxial Anisotropies

  • Nam, Yoon Jae;Lee, Tae Young;Lim, Sang Ho
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.232-236
    • /
    • 2014
  • Anisotropy coupling in thin films with mixed induced and shape anisotropies is investigated. A 200-nm-thick Co-Fe-Pd-B thin film with a large induced anisotropy of 57 Oe is fabricated and then patterned into micron-sized cells to provide shape anisotropy, whose strength has a similar magnitude to that of the induced anisotropy for enhancing the anisotropy coupling. The angles between the two mixed anisotropies considered are $0^{\circ}$, $90^{\circ}$, and $110^{\circ}$. Hysteresis loops measured under in-plane magnetic fields along various directions indicate no anisotropy coupling behaviour for all the three angles examined in this study.