• Title/Summary/Keyword: PD detection

Search Result 270, Processing Time 0.031 seconds

Preparation of $SnO_2$ Semiconducting Gas Sensor by Wet Process (습식방법에 의한 $SnO_2$ 반도체 가스센사 제조)

  • 전병식;김홍대;최병현;최성근
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.3
    • /
    • pp.53-61
    • /
    • 1986
  • A gas sensor which has been made by wet process had fabricated by coating each of the mixture on alumina tube and firing at 85$0^{\circ}C$ for 3hrs. A gas concentration such $H_2$, CO, $C_3H_8$, $C_2H_2$ and $CH_4$ vs its detection voltage characteristics has been in-vestigated on $SnO_2-In_2O_3-MgO$ system doped with PdO, $La_2O_3$, $ThO_2$, NiO and $Nb_2O_5$ The optimum sensitivity composition for various gases were 90w/o $SnO_2$-9w/o $In_2O_3$-1w/o MgO for $H_2$, $C_2H_2$ CO and $C_3H_8$ and 95w/o $SnO_2$-4w/o $In_2O_3$-1w/o MgO for $CH_4$. The sample which has been made by wet process than dry process had predominated sensitivity for each gases and particle size of the sample coprecipitated with PH=9 was 0.1${\mu}{\textrm}{m}$ The $SnO_2$-In2_O_3-MgO$ system doped with 2w/o $Nb_2O_5$ and NiO was the most sensitive for $H_2$ and $C_2H_2$ gas. In $SnO_2$-In2_O_3-MgO$ system doped with $ThO_2$ the sensitivity of $H_2$ gas was decreased but CO gas was in-creased when dopant con was increased.

  • PDF

Phase-Shifting System Using Zero-Crossing Detection for use in Fiber-Optic ESPI (영점검출을 이용한 광섬유형 전자 스페클 패턴 간섭계의 위상이동)

  • Park, Hyoung-Jun;Song, Min-Ho;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.516-520
    • /
    • 2005
  • We proposed an efficient phase stepping method for the use in fiber-optic ESPI. To improve phase-stepping accuracy and efficiency, a fiber-optic Michelson interferometer was phase-modulated by a ramp-driven fiber stretcher, resulting in 4$\pi$ phase excursion in the PD interference signal. The zero-crossing points of the signal, which have consecutive $\pi$ phase difference, were carefully detected and used to generate trigger signals for the CCD camera. From the experimental results by using this algorithm, $\pi$/2 phase-stepping errors between the speckle patterns were measured to be less than 0.6 mrad with 100 Hz image capture speed. Also it has been shown that the error from the nonlinear phase modulation and environmental perturbations could be minimized without any feedback algorithm.

FMCW Radar simulation model with interference using a new radar performance parameter (새로운 레이더 성능지표를 이용한 FMCW 레이더 간섭 시뮬레이션 모델)

  • Mun, Sang-Kon;Park, Seung-Keun;Yang, Hoon-Gee;Cheon, Chang-Yul;Chung, Young-Seek;Bae, Kyung-Bin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.86-92
    • /
    • 2011
  • ITS(Intelligent Transport System) has been researched actively to guarantee the smooth traffic and the safety of the vehicle. In recent, as the sensor for the measurement of distance between vehicles, the FMCW radar system in millimeter wave band has been interested in ITS. Actually, 47, 60, 77, 94 and 139 GHz have been assigned for the vehicle radar frequencies in Europe and Japan. However, the performances of the FMCW radar are deteriorated due to the interferences from the surrounding radars and mobile devices. In this paper, in order to model and simulate the performance of FMCW radar under the exterior interference, we propose a new performance parameter, RER(Radius Error Rate), which contains the information of the range error due to the interferences, and show the effectiveness of the proposed parameter.

A Development on Deep Learning-based Detecting Technology of Rebar Placement for Improving Building Supervision Efficiency (감리업무 효율성 향상을 위한 딥러닝 기반 철근배근 디텍팅 기술 개발)

  • Park, Jin-Hui;Kim, Tae-Hoon;Choo, Seung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.93-103
    • /
    • 2020
  • The purpose of this study is to suggest a supervisory way to improve the efficiency of Building Supervision using Deep Learning, especially object detecting technology. Since the establishment of the Building Supervision system in Korea, it has been changed and improved many times systematically, but it is hard to find any improvement in terms of implementing methods. Therefore, the Supervision is until now the area where a lot of money, time and manpower are needed. This might give a room for superficial, formal and documentary supervision that could lead to faulty construction. This study suggests a way of Building Supervision which is more automatic and effective so that it can lead to save the time, effort and money. And the way is to detect the hoop-bars of a column and count the number of it automatically. For this study, we made a hoop-bar detecting network by transfor learnning of YOLOv2 network through MATLAB. Among many training experiments, relatively most accurate network was selected, and this network was able to detect rebar placement in building site pictures with the accuracy of 92.85% for similar images to those used in trainings, and 90% or more for new images at specific distance. It was also able to count the number of hoop-bars. The result showed the possibility of automatic Building Supervision and its efficiency improvement.

A Hierarchical Cluster Tree Based Fast Searching Algorithm for Raman Spectroscopic Identification (계층 클러스터 트리 기반 라만 스펙트럼 식별 고속 검색 알고리즘)

  • Kim, Sun-Keum;Ko, Dae-Young;Park, Jun-Kyu;Park, Aa-Ron;Baek, Sung-June
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.562-569
    • /
    • 2019
  • Raman spectroscopy has been receiving increased attention as a standoff explosive detection technique. In addition, there is a growing need for a fast search method that can identify raman spectrum for measured chemical substances compared to known raman spectra in large database. By far the most simple and widely used method is to calculate and compare the Euclidean distance between the given spectrum and the spectra in a database. But it is non-trivial problem because of the inherent high dimensionality of the data. One of the most serious problems is the high computational complexity of searching for the closet spectra. To overcome this problem, we presented the MPS Sort with Sorted Variance+PDS method for the fast algorithm to search for the closet spectra in the last paper. the proposed algorithm uses two significant features of a vector, mean values and variance, to reject many unlikely spectra and save a great deal of computation time. In this paper, we present two new methods for the fast algorithm to search for the closet spectra. the PCA+PDS algorithm reduces the amount of computation by reducing the dimension of the data through PCA transformation with the same result as the distance calculation using the whole data. the Hierarchical Cluster Tree algorithm makes a binary hierarchical tree using PCA transformed spectra data. then it start searching from the clusters closest to the input spectrum and do not calculate many spectra that can not be candidates, which save a great deal of computation time. As the Experiment results, PCA+PDS shows about 60.06% performance improvement for the MPS Sort with Sorted Variance+PDS. also, Hierarchical Tree shows about 17.74% performance improvement for the PCA+PDS. The results obtained confirm the effectiveness of the proposed algorithm.

Neuropsychiatric Evaluation of Head-Injured Patients(I) : Comparison of Structural and Functional Brain Studies in Post-Traumatic Organic Mental Disorder (두부외상 환자의 신경정신의학적 평가(I) : 외상후 기질성정신장애 환자에서 뇌의 구조적 및 기능적 검사소견의 비교)

  • Yi, Jang Ho;Chang, Hwan-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.57-65
    • /
    • 1996
  • The Evaluation of patients complaining of psychiatric symptoms following head injury is much affected by the results of various tests. The objecive of this paper is to investigate the effectiveness of each lest by comparing the structual and fuctional brain studies. The subjects were 93 organic menial disorder in and out patients at the Dept. of Neuropsychiatry of the Kyung Hee University Hospital. After carrying out MRI, CT, SPECT, EEG, the results of each were analysed for the sesitivity and ability to detect focal lesion. The degree of inter-test correlations of lest results were also investigated. Furthermore, the characteristic features of psychological tests were studied and the relationship between each of above mentioned tests and psychological test was examined. As for the test sensitivity to diagnosis, the SPECT was the most superior followed by MRI, CT, EEG in thai order. In the case of abnormality, SPECT ranked 1st in detection of focal lesion, followed by MRI, CT in that order. In the inter-test result correlation, the correlation of SPECT-MRI was statistically significant. When mare than moderate abnormality EEG finding was reported, it correlated significantly with that of MRI findings. In the MMPI, the average scores on F, Hs, D, Hy, Pa, Pt, Sc subscales were above 60. Abnormal SPECT group scored significantly high on the F, Pd, Pa, Sc, Ma scales and therefore in comparison ot the SPECT normal group, displayed more psychotic features. In K-WAIS, the mean full scale IQ was down to 77. 23(Verbal IQ : 78.76, Performance IQ : 77.44) but there was no characterogic significant relationship between the lowered to and abnormal SPECT, MRI, CT and EEG results. In conclusion, 1) The SPECT was mast superior in sensitivity and detection of focal lesions. In comparision with other tests, the results of SPECT correlated well with MRI had thus is thought to be very usefull testing method in the evaluation of organic mental disorder patients. 2) The MRI had relatively high sensitivity, ability to detect focal lesion and superior correlation with other test. 3) Although EEG fared less an sensitivity in comparison to other tests, the results of above moderate abnormal grade group and that of MRI correlated significantly. 4) In the MMPI highly scored in F, Hs, D, Hy, Pa, Pt, Sc subscales and abnormal SPECT patients were shown to display more sever psychotic features. There was no significant character relationship between the lowered IQ(in K-WAIS) and abnormal findings on MRI, CT, SPECT, EEG.

  • PDF

Prevalence Report of Transovarian Transmitted Diseases in the Breeder Chickens, Korea (국내 종계에서 난계대 전염병 감염 실태 보고)

  • Kwon, Yong-Kuk;Kang, Min-Soo;Oh, Jae-Young;Jung, Byeong-Yeal;Kim, Hye-Ryoung;Kim, Ha-Young;Shin, So-Yeon;Kwon, Jun-Hun;Chung, Gab-Soo
    • Korean Journal of Poultry Science
    • /
    • v.37 no.3
    • /
    • pp.237-245
    • /
    • 2010
  • A survey of transovarially transmitted diseases, including salmonellosis [(pullorum disease; PD)/(fowl typhoid; FT)], mycoplasmosis, avian infectious anemia (CIA), and fowl adenovirus infection was conducted in the breeder chickens from August to December in 2009. The numbers of flocks sampled out were: Grand Parents Stock (GPS), 45; Parents Stock (PS) 1,018, Baeksemi breeder (BSB) 54. The seroprevalence of salmonellosis (PD/FT) were 0% (GPS), 3.2% (PS), and 3% (BSB), respectively. A total of 983 chicken farms were affected with FT outbreaks between 2000 and 2008. The incidence of FT in commercial broilers, Baeksemi, commercial layers, native chickens, and broiler breeders was 44.3%, 26.2%, 15.7%, 12.6% and 1.08%, respectively. Of the affected broilers, over 90% birds were under 2 weeks of age, indicating it was possible that they were infected with S. gallinarum via vertical transmission. The sero-positive flocks against Mycoplasma gallisepticum (MG) were 71.1% (GPS), 88.7% (PS), 88.7% (BSB), while the rates of positive flocks against Mycoplasma synoviae (MS) were 86.0% (GPS), 77.0% (PS), and 98.0% (BSB). In GP and parent farms, the detection rates on specific genes of CIA virus were 19/45 (42.2%), and 169/1039 (18.0%), respectively, whereas the seroprevalence of CIA were 86.0% in GPS and 93.7% in PS flocks. In addition, positive flocks of fowl adenoviruses were 4.4% (GPS), 2.7% (PS) and 9.35% (BSB), respectively. As the results, avian mycoplasmosis and CIA have been more prevailing in chicken breeder than avian salmonellosis and fowl adenovirus infection in Korea.

Cl--Channel Is Essential for LDL-induced Cell Proliferation via the Activation of Erk1/2 and PI3K/Akt and the Upregulation of Egr-1 in Human Aortic Smooth Muscle Cells

  • Heo, Kyung-Sun;Ryoo, Sung-Woo;Kim, Lila;Nam, Miyoung;Baek, Seung-Tae;Lee, Hyemi;Lee, Ah-Reum;Park, Song-Kyu;Park, Youngwoo;Myung, Chang-Seon;Kim, Dong-Uk;Hoe, Kwang-Lae
    • Molecules and Cells
    • /
    • v.26 no.5
    • /
    • pp.468-473
    • /
    • 2008
  • Low-density lipoprotein (LDL) induces cell proliferation in human aortic smooth muscle cells (hAoSMCs), which may be involved in atherogenesis and intimal hyperplasia. Recent studies have demonstrated that $Cl^-$ channels are related to vessel cell proliferation induced by a variety of stimuli. In this study, we investigated a potential role of $Cl^-$ channels in the signaling pathway of LDL effects on hAoSMC proliferation with a focus on the activation of Erk1/2-PI3K/Akt and the subsequent upregulation of Egr-1. $Cl^-$ channel blockers, DIDS, but neither NPPB nor Furosemide, completely abolished the LDL-induced DNA synthesis and cell proliferation. Moreover, DIDS, but not NPPB, significantly decreased LDL-stimulated $Cl^-$ concentration, as judged by flow cytometry analysis using MQAE as a $Cl^-$-detection dye. DIDS pretreatment completely abolished the activation of Erk1/2 and PI3K/Akt in a dose-dependent manner that is the hallmark of LDL activation, as judged by Western blot and proliferation assays. Moreover, pretreatment with DIDS ($Cl^-$ channel blockers) but not LY294002 (PI3K inhibitors) completely abolished the LDL-induced upregulation of Egr-1 to the same extent as PD98059 (MEK inhibitors to inhibit Erk), as judged by Western blot and luciferase reporter assays. This is the first report, to our knowledge, that DIDS-sensitive $Cl^-$-channels play a key role in the LDL-induced cell proliferation of hAoSMCs via the activation of Erk1/2 and PI3K/Akt and the upregulation of Egr-1.

Pharmacokinetic/Pharmacodynamic Analysis of Metoprolol in Dogs (실험견에서 Metoprolol 약리효과의 약동/력학적 검토)

  • Oh, Dong-Jin;Jang, In-Jin;Lee, Kyung-Hun;Yim, Dong-Seok;Kim, Hyung-Kee;Shin, Sang-Goo;Park, Chan-Woong;Shin, Jae-Gook
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.2
    • /
    • pp.251-259
    • /
    • 1995
  • Pharmacokinetics and pharmacodynamics of metoprolol, a selective beta-l blocker, were examined for 360 minutes after intravenous bolus administration of metoprolol to 6 dogs. Plasma concentration and excreted amount in the urine metoprolol were measured by liquid chromatography with fluorescence detection. PR interval and heart rate were measured by ECG monitoring. Blood pressure was monitored through intraarterial catheter in femoral artery and cardiac output by thermodilution method using Swan-Ganz catheter. To analyze the effect site concentration-response relationship, plasma concentration and pharmacological effects were simultaneously fitted to a two pharmacokinetic compartment linked to pharmacodynamic model with NONLIN program. Results are as follows. 1) The plasma concentration of metoprolol after intrvenous injection decreased biexponentially. The terminal half-life estimated was $1.33{\pm}0.40$ hours and the volume of distribution at steady state (Vdss) and the total body clearance were $1.04{\pm}0.4\;L/kg,\;6.55{\pm}2.21\;L/hr$, respectively. The central compartment volume of distribution and peripheral compartment volume of distribution were $0.35{\pm}0.14L/kg\;and\;0.69{\pm}0.34L/kg$. The renal clearance and intercompartment clearance were $0.53{\pm}0.25\;L/min\;and\;0.35{\pm}0.19\;L/min$. 2) Simulated biophase concentration-response curve shows hyperbolic relationship and the estimated concentration-effect relationship was best explained by Emax model when the prolongation of PR interval and the reduction of the heart rate were used as pharmacodynamic parameters. Emax and EC50 were estimated to be $26.3{\pm}4.7\;msec\;and\;88.8{\pm}82.3\;g/ml$ for PR interval, and $48.7{\pm}18.8\;beats/min\;and\;113.5{\pm}78.7\;ng/ml$ for heart rate, respectively. 3) The changes of cardiac output-effect site concentration relationship was best fitted by a linear model and the slope of the relationship was $0.005{\pm}0.003$. Diastolic blood pressure-effect site concentration relationship was also explained by the linear model and the slope of the relationship was $0.038{\pm}0.034$.

  • PDF

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.