포켈스 센서를 이용한 부분 방전 측정 기술의 GITR 적용 (An application of the Novel Method to Detect Partial Discharges for GITR using Pockels Sensor)

  • 이재호;장용무;구자윤;박기준;이영상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1997-1999
    • /
    • 2004
  • In this paper, a novel method has been proposed by use of HY-Pockels sensor for the detection of PD in GITR(Gas Insulated Transformer) in order to improve reliability and to overcome the shortcomings of other techniques which are currently employed. For this work, different types of the test specimen, simulating the winding of the real GITR, have been designed and fabricated to generate the PD. And then, the detection of PD has been realized by conventional methods according to IEC 270 and also the proposed novel sensor as well. Afterwards, their results are well compared to understand the correlation between the nature of the defects in the winding and their PD pattern.

  • PDF

Implementation of an Inductively Coupled EM Probe System for PD Diagnosis

  • Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.111-118
    • /
    • 2011
  • In recent years, various types of partial discharge (PD) methods such as capacitive, inductive, electromagnetic, and acoustic coupling techniques have been developed for diagnosing rotating machines. An electromagnetic (EM) probe, which is an inductively coupled type of sensor, is required for detecting corona and internal discharges during off-line tests. In this study, a new technique for enhancing the measurement sensitivities for corona and internal discharge based on an EM inductive position sensor is proposed. An EM probe that winds wires around horseshoe-shaped and cylindershaped ferrites as helices is designed and optimized for the implementation of off-line PD monitoring of the stator winding of a rotating machine. The measurement system based on this design is implemented, and it is verified from the results of the experiment performed in this study that the probe provides similar performance as existing commercial products.

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

Pd/다결정 3C-SiC 쇼트키 다이오드형 수소센서의 제작과 그 특성 (Fabrication of a Pd/poly 3C-SiC Schottky diode hydrogensensor and its characteristics)

  • 정귀상;안정학
    • 센서학회지
    • /
    • 제18권3호
    • /
    • pp.222-225
    • /
    • 2009
  • This paper describes the fabrication and characteristics of Schottky micro hydrogen sensors for high temperatures by using polycrystalline(poly) 3C-SiC thin films grown on Si substrates with thermal oxide layer using APCVD. Pd/poly 3C-SiC Schottky diodes were made and evaluated by I-V and C-V measurements. Electric current density and barrier height voltage were $2{\times}10^{-3}A/cm^2$ and 0.58 eV, respectively. These devices could operate stably at about 400 $^{\circ}$. The characteristics of implemented sensors have been investigated in terms of sensitivity, linearity of response, response rate, and response time. Therefore, from these results, Pd/poly 3C-SiC Schottky devices have very high potential for high temperature $H_2$ sensor applications.

A highly integrable p-GaN MSM photodetector with GaN n-channel MISFET for UV image sensor system

  • Lee, Heon-Bok;Hahm, Sung-Ho
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.346-349
    • /
    • 2008
  • A metal-semiconductor-metal (MSM) ultraviolet (UV) photodetector (PD) is proposed as an effective UV sensing device for integration with a GaN n-channel MISFET on auto-doped p-type GaN grown on a silicon substrate. Due to the high hole barrier of the metal-p-GaN contact, the dark current density of the fabricated MSM PD was less than $3\;nA/cm^2$ at a bias of up to 5 V. Meanwhile, the UV/visible rejection ratio was 400 and the cutoff wavelength of the spectral responsivity was 365 nm. However, the UV/visible ratio was limited by the sub-bandgap response, which was attributed to defectrelated deep traps in the p-GaN layer of the MSM PD. In conclusion, an MSM PD has a high process compatibility with the n-channel GaN Schottky barrier MISFET fabrication process and epitaxy on a silicon substrate.

Synthesis and Sensing Properties of Pd Nanoparticle-Functionalized SnO2 Nanowires

  • Akash, Katoch;Choi, Sun-Woo;Kim, Eun-Kyeong;Kim, Sang-Sub
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.289-293
    • /
    • 2011
  • Networked $SnO_2$ nanowires were uniformly functionalized with Pd nanoparticles via ${\gamma}$-ray radiolysis. The Networked $SnO_2$ nanowires were fabricated through a selective growth method. The sensing properties of the Pd-functionalized $SnO_2$ nanowires were analyzed in terms of their response to $NO_2$ and CO gases. The response time and sensitivity of the sensors were significantly improved for $NO_2$ at lower temperatures by the Pd functionalization. The enhancement in the sensing properties is likely to be due to the spillover effect of the Pd nanoparticles.

Pd 나노갭 수소 센서의 신뢰성 연구 (Reliability Test of Pd Nanogap-Based Hydrogen Sensors)

  • 박세영;김원경;이우영
    • 센서학회지
    • /
    • 제29권6호
    • /
    • pp.399-406
    • /
    • 2020
  • Pd nanogap hydrogen sensors were developed using an elastomeric substrate and operated through an on-off mechanism. A 10 nm thick Pd thin film was formed on a polydimethylsiloxane (PDMS) substrate, and 50% of the physical strain was applied in the longitudinal direction to fabricated uniform nanogaps. The initial concentration of the hydrogen gas for the PDMS/Pd films was controlled, and subsequently, the on-off switching response was measured. We found that the average nanogap was less than 50 nm, and the Pd nanogap hydrogen sensors operated over a wide range of temperatures. In particular, the sensors work properly even at a very low temperature of -40℃ with a fast response time of 2 s. In addition, we have investigated the relative humidity and annealing effects.

MR센서를 이용한 무인 주행 시스템 설계 (Development of an Unmanned Vehicle Driving system By the MR Sensor)

  • 김창섭;박기선;이영진;이만형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.587-590
    • /
    • 2000
  • By using the information obtained from output of the MR(Magneto Resistive) sensor for an unmanned vehicle system which is used in the Local Position System. We develop an algorithm that decides the distance and directions between the guideline made by magnets and vehicle, and make an unmanned vehicle driving system that is steered by PD controller and MR sensor

  • PDF

GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

주파수대역 검출센서를 이용한 전력케이블의 부분방전 진단 시스템 (A Partial Discharge Diagnostic System for Power Cable Using FBDS(Frequency Band Detection Sensor))

  • 이철희;최형기;홍수미;정의붕;박기영
    • 전자공학회논문지
    • /
    • 제54권1호
    • /
    • pp.157-163
    • /
    • 2017
  • 본 논문은 주파수대역검출센서(FBDS)를 이용하여 전력 케이블에서 부분방전(PD)가 발생했을 때 이것을 검출하고 진단하는 시스템 개발에 관한 논문이다. 주파수대역검출센서는 각 주파수대역에서 발생하는 부분방전을 음향학적으로 변환하여 검출한다. 부분방전은 그 음향학적 신호 형태로 잡음과 유사하다. 따라서 본 논문에서 상대적 레벨교차율(RLCR)과 주파수에너지 스펙트럼을 이용하여 정상과 비정상을 구별하여 부분방전을 검출하였다.