• 제목/요약/키워드: PD Sensor

검색결과 372건 처리시간 0.018초

Palladium-based Electrical and Optical Hydrogen Gas Sensors

  • Jinwoo, Lee;Minah, Seo
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.397-402
    • /
    • 2022
  • In this short review, we explore the recent progress in metal-based gas-sensing techniques. The strong interaction between the metal films and hydrogen gas can be considered to play a considerably important role in the gas-sensing technique. The physical and chemical reactions in Pd-Pd hydride systems were studied in terms of the phase transition and lattice expansion of the metals. Two types of represented detection, electrical and optical, were introduced and discussed along with their advantages.

Taguchi 실험 계획법에 의한 CH3SH 반도체 악취 가스 센서의 개발 (Development of a Semiconductor Odor Gas Sensor for the Measurement of CH3SH with Taguchi Experimental Design)

  • 김선태;최일환
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.783-792
    • /
    • 2004
  • In this study, a thick-film semiconductor odor gas sensor for the detection of $CH_3$SH was developed using SnO$_2$ as the main substrate and was investigated in terms of its sensitivity and reaction time. In the process of manufacturing the sensor, Taguchi's design of experiment (DOE) was applied to analyze the effects of a variety of parameters, including the substrate, the additives and the fabrication conditions, systematically and effectively. Eight trials of experiments could be possible using the 27 orthogonal array for the seven factors and two levels of condition, which originally demands 128 trials of experiments without DOE. The additives of Sb$_2$O$_{5}$ and PdCl$_2$ with the H$_2$PtCl$_{6}$ ㆍ6$H_2O$ catalyst were appeared to be important factors to improve the sensitivity, and CuO, TiO$_2$, V$_2$O$_{5}$ and PdO were less important. In addition, TiO$_2$, V$_2$O$_{5}$ and PdO would improve the reaction time of a sensor, and CuO, Sb$_2$O$_{5}$, PdCl$_2$ and H$_2$PtCl$_{6}$ㆍ6$H_2O$ were negligible. Being evaluated simultaneously in terms of both sensitivity and reaction time, the sensor showed the higher performance with the addition of TiO$_2$ and PdO, but the opposite results with the addition of CuO, V$_2$O$_{5}$, Sb$_2$O$_{5}$ and PdCl$_2$. The amount of additives were superior in the case of 1% than 4%. H$_2$PtCl$_{6}$ㆍ6$H_2O$ would play an important role for the increase of sensor performance as a catalyst.nce as a catalyst.

수소 센서용 Pd 첨가한 WO3 박막의 특성 (Characteristics of Pd-doped WO3 thin film for hydrogen gas sensor)

  • 김광호;최광표;권용;박진성
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.120-126
    • /
    • 2006
  • Physicochemical and electrical properties for hydrogen gas sensors based on Pd-deposited $WO_3$ thin films were investigated as a function of Pd thickness, annealing temperature, and operating temperature. $WO_3$ thin films were deposited on an insulating material by thermal evaporator. XRD, FE-SEM, AFM, and XPS were used to evaluate the crystal structure, microstructure, surface roughness, and chemical property, respectively. The deposited films were grown $WO_3$ polycrystalline with rhombohedral structure after annealing at $500^{\circ}C$. The addition effect of Pd is not the crystallinity but the suppression of grain growth of $WO_3$. Pd was scattered an isolated small spherical grain on $WO_3$ thin film after annealing at $500^{\circ}C$ and it was agglomerated as an irregular large grain or diffused into $WO_3$ after annealing at $600^{\circ}C$. 2 nm Pd-deposited $WO_3$ thin films operated at $250^{\circ}C$ showed good response and recovery property.

Pd가 코팅된 광섬유 센서를 이용한 수소 검출 시스템 (Hydrogen detection system based on Pd coated fiber sensor)

  • 박선옥;박규하;양병철;김광택;김태언;김회종;백세종;임기건
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.347-348
    • /
    • 2007
  • We have implemented a hydrogen detection system based on a Pd coated fiber sensor. The configuration of the system and the characteristics of the hydrogen sensor was presented.

  • PDF

MV급 케이블 중간접속부의 PD 측정을 위한 UHF-센서와 HFCT-센서의 비교시험 (Comparison test for PD measuring about UHF-sensor and HFCT-sensor in cable joint-box of MV grade)

  • 신동훈;이용성;김정윤;양종석;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1511-1512
    • /
    • 2006
  • In this paper, we measured PD signals from artificial surface defects and corona discharges under laboratory circumstances like the fields using both HFCT-sensor and UHF-sensor for MV grade XLPE cable with AMP, spectrum analyzer and oscilloscope. Also, detected signals were analyzed via PRPDA system in this paper. As a result, in this case of HFCT-sensor, the amount of background noise are larger than as compared to UHF-sensor. There is needed some hardware or software or software algorithm removing background noise effectively for diagnosis the underground power transmission cable in the case of HFCT-sensor.

  • PDF

Flexible Hydrogen Sensor Using Ni-Zr Alloy Thin Film

  • Yun, Deok-Whan;Park, Sung Bum;Park, Yong-il
    • 한국재료학회지
    • /
    • 제29권5호
    • /
    • pp.297-303
    • /
    • 2019
  • A triple-layered $PMMA/Ni_{64}Zr_{36}/PDMS$ hydrogen gas sensor using hydrogen permeable alloy and flexible polymer layers is fabricated through spin coating and DC-magnetron sputtering. PDMS(polydimethylsiloxane) is used as a flexible substrate and PMMA(polymethylmethacrylate) thin film is deposited onto the $Ni_{64}Zr_{36}$ alloy layer to give a high hydrogen-selectivity to the sensor. The measured hydrogen sensing ability and response time of the fabricated sensor at high hydrogen concentration of 99.9 % show a 20 % change in electrical resistance, which is superior to conventional Pd-based hydrogen sensors, which are difficult to use in high hydrogen concentration environments. At a hydrogen concentration of 5 %, the resistance of electricity is about 1.4 %, which is an electrical resistance similar to that of the $Pd_{77}Ag_{23}$ sensor. Despite using low cost $Ni_{64}Zr_{36}$ alloy as the main sensing element, performance similar to that of existing Pd sensors is obtained in a highly concentrated hydrogen atmosphere. By improving the sensitivity of the hydrogen detection through optimization including of the thickness of each layer and the composition of Ni-Zr alloy thin film, the proposed Ni-Zr-based hydrogen sensor can replace Pd-based hydrogen sensors.

로고스키코일을 이용한 기중 방전 신호 검출 (Air Discharge Detection using Rogowski Coil)

  • 박성희;이용희;이강원;김길수;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1884-1886
    • /
    • 2002
  • At present, the variable sensors are applied to detect PD pulse signals, UHF sensor, AE sensor and etc. In this paper we used the Rogowski sensor to detect PD pulse signals in air. We did performed test simulation and niddle to plane electrode structure for PD source. We compared Rogowski sensor with conventional type PD detector to detect discharge signals in air.

  • PDF

회전기 고정자 권선의 부분방전 측정용 RFCT 특성 (Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines)

  • 강동식;윤대희;황돈하;김용주;장기찬;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

진공여과증착법을 이용한 SWNT-PdOx계 수소센서 (Hydrogen sensor of SWNT-PdOx system using the vacuum filtering deposition method)

  • 김일진;박기배
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.87-91
    • /
    • 2010
  • Hydrogen gas sensors were fabricated using $PdO_x$ loaded with SWNTs. The nanoparticle powders of $SWNT_s-PdO_x$ composite were deposited on Si wafer substrates by a vacuum filtering deposition method. The fabricated sensors were tested against hydrogen gas. The composition ratio that exhibited the highest response to hydrogen gases was SWNTs : $PdO_x$ = 98 : 2 in wt% ratio at operating temperature of about $150^{\circ}C$. The response and recovery times were shorter than 1.0 min. in presence of 1000 ppm hydrogen.

고온 화학센서용 다결정 3C-SiC 쇼트키 다이오드 제작과 그 특성 (Fabrication and characteristics of polycrystalline 3C-SiCSchottky diodes for high temperature chemical sensors)

  • 정귀상;안정학
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.414-417
    • /
    • 2008
  • This paper describes the fabrication of a Pd/poly 3C-SiC Schottky diode and its characteristics, in which the poly 3C-SiC layer and Pd Schottky contact were deposited by using APCVD and sputter, respectively. Crystalline quality, uniformity, and preferred orientations of the Pd thin film were evaluated by SEM and XRD, respectively. Pd/poly 3C-SiC schottky diodes were fabricated and characterized by I-V and C-V measurements. Its electric current density Js and barrier height voltage were measured as $2{\times}10^{-3}A/cm^2$ and 0.58 eV, respectively. These devices were operated until about $400^{\circ}C$. Therefore, from these results, Pd/poly 3C-SiC Schottky devices have very high potential for high temperature chemical sensor applications.