• 제목/요약/키워드: PD (Partial Discharge)

검색결과 501건 처리시간 0.028초

투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발 (Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance)

  • 김영석;송길목;방선배;김종민;최명일;김우진
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

초고압용 조립형 접속함 모의계면에서 압력에 따른 절연파괴 및 부분방전 특성 (Breakdown Voltage and Partial Discharge Characteristics at the Simulated Interface in a Prefabricated Joint for Ultra High Voltage Cable)

  • 김정년;백주흠;신두성;이창영;김충식;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1099-1101
    • /
    • 1999
  • PJB(Prefabricated Joint Box) is consisted of three major components ; an epoxy unit, a stress relief cone and a spring unit. The insulation structure of PJB is maintained by the interfacial pressure, and the dielectric performance at the interface depends on the interfacial pressure which is regarded as the most important factor for preventing breakdown failure. This experiment was performed to investigate breakdown voltage characteristic and partial discharge patterns under the controlled pressure conditions at the simulated interface. Finally, this paper presents the optimal pressure conditions at the interface by analyasing the PD patterns.

  • PDF

GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증 (Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

Genetic Algorithm을 이용한 부분방전 패턴인식 최적화 연구 (A Study on Optimization of Partial Discharge Pattern Recognition using Genetic Algorithm)

  • 김성일;정승용;구자윤;장용무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.145-146
    • /
    • 2006
  • 본 논문은 부분방전(PD: Partial Discharge)의 패턴인식 확률 극대화를 목적으로 신경망(NN: Neural Network) 파라미터 중에서 은닉층 뉴런의 수, 모멘텀(momentum)의 Step size와 Decay rate 를 최적화하기 위하여 유전 알고리즘(GA: Genetic Algonthm)을 적응하였다. 실험적 연구의 대상으로서, GIS(Gas Insulated Switchgear)사고의 주요 원인으로 보고되어있는 결함들을 인위적으로 모의한 16개 Test cell을 이용하여 부분방전을 발생시켰다. 부분방전 신호는 본 연구팀이 개발한 센서를 이용하여 검출되어 데이터베이스가 구축되어 그로부터 추출된 학습 데이터들의 학습에 다음과 같은 5가지 신경망 모델이 적응되었다: Multilayer Perception (MLP), Jordan-Elman Network (JEN), Recurrent Network (RN), Self-Organizing Feature Map (SOFM), Time-Lag Recurrent Network (TLRN). 유전 알고리즘 적용 효율성을 분석하기 위하여 동일한 데이터를 이용하여 다음과 같은 두 가지 방법을 적용한 결과를 상호 비교하였다. 우선 상기 선택된 모델만 적용하였고 다근 하나는 상기 모델과 Genetic Algorithm이 동시에 적용되었다. 모든 모델에 대하여 학습오차와 패턴 분류 확률을 비교한 결과, 유전 알고리즘 적응 시 부분방전 패턴인식 확률이 향상되었음이 확인되어 향후 신뢰성 있는 GIS 부분방전 진단기술에 활용될 수 있을 것으로 사료된다.

  • PDF

고압 전동기 고정자 권선의 상태진단을 위한 운전중 모니터링 시스템 개발 (Development of On-Line Monitoring System for Insulation Diagnosis of High-Voltage Motor Stator Windings)

  • 황돈하;심우용;김용주;송상옥;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1701-1703
    • /
    • 2002
  • This paper introduces a on-line monitoring system for insulation diagnosis of high-voltage motor stator windings. This system monitors the insulation condition of the stator winding with sensor, coupling capacitor. Partial discharge (PD) signals are able to be continuously measured and digitalized with a Peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. This system can communicate with the central monitoring system via RS-485 This paper introduces an economic solution for data acquisition of partial discharges.

  • PDF

Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.

지중송전 XLPE케이블 활선상태 PD 측정기술 향상을 위한 가이드라인 제시 (Guideline for Field Partial Discharge measurement of Underground Transmission Level XLPE Cable)

  • 박진우;최경규;이전선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.141-142
    • /
    • 2008
  • 국내 지중송전선로는 주로 XLPE케이블과 OF케이블로 구성된다. 1971년 154kV급 OF 케이블이 최초로 한전에 의해 상용운전에 들어간 후 XLPE 케이블 지중선로가 1983년부터 병용운전 되고 있으며 OF케이블의 경우 절연유의 사용으로 인한 화재의 위험과 환경오염 문제 등으로 인하여 점진적으로 XLPE케이블로 대체되는 추세에 있다. 하지만 내전압 시험, 절연저항이나 누설전류 측정, $tan{\delta}$ 측정 등으로 진단이 가능했던 OF케이블과는 달리 XLPE케이블의 경우 종래의 시험을 통한 진단은 한계가 있고 부분방전을 통한 진단이 가장 효율적인 진단방법으로 제시되어 국내외 XLPE케이블의 진단을 위해 운영되고 있으며 보다 정확한 PD측정을 위한 연구가 계속 진행되고 있다. 지난 10년여간의 국내외 연구결과 XLPE케이블에 대한 PD 측정기술의 정확성은 상당히 향상되었고 그 결과물로서 수많은 폭정 장비와 기법이 개발되어 오늘날 널리 보급되고 있다. 하지만 여전히 측정된 Data에 대한 해석은 일부 전문가들에게 조차 복잡하고 어려운 일로 남아 있다. 자칫 그릇된 해석은 향후 큰 사고로 이어질 수 있으므로 선로 운영자의 입장에서는 측정결과의 신뢰성에 민감할 수밖에 없다.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석 (Fatten Analysis of Trouble Signal on DS for GIS using Neural Network)

  • 김종서;이은석;천종철
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1310-1315
    • /
    • 2003
  • GIS(Gas Insulated Switchgear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. But, because of structural characteristics, this is difficult to monitor externally and provide much loss in the event of an accident. Recently, because equipment of GIS is occurring problem of confidence used for a long time, development of diagnosis technique have been importantly recognized. therefore, measurement and analysis of PD much has been generally used for equipment of GIS. But, in case of measurement of PD at field, real trouble signals is difficult to classify noise. Accordingly, a variety of trouble conditions for DS are simulated, and detected signals are analyzed by the application of electrical and mechanical methods. For this analysis, detected signals are accumulated according to phase-magnitude with the application of induction sensor, and then we analyzed the characteristics. For the simulation experiment, we make DS for 170KV GIS and analyze the characteristics of detected signals with the application of neural network algorithm. last, we have measured DS for GIS at field, and then have analyzed detected signals.

PD 신호의 주파수 분석이 고려된 GIS 절연 결함 분류를 위한 Advanced PRPD 패턴인식 (An advanced PRPD Pattern recognition method considering frequency analysis of the PD signals detected in GIS)

  • 박재홍;정승용;류철휘;김영홍;이영조;임윤석;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1443-1444
    • /
    • 2007
  • 지속적으로 증가되는 전기에너지 공급의 신뢰성을 높이기 위하여 전력설비 주요 사고 원인인 부분방전(PD : Partial Discharge)을 검출하고 결함원의 패턴인식 방법의 개발 필요성 날로 증가되고 있다. 본 논문은 부분방전의 패턴인식 확률을 높이기 위하여 검출된 부분방전의 주파수 분석을 이용하여 Conventional PRPD Analysis 방법의 결함 판독확률을 향상시키기 위하여 Advanced PRPD를 제안 한다. 이를 위하여, GIS(Gas Insulated Switchgear)의 주요 사고원인으로 인식되어 있는 결함들을 인위적으로 제작 후 삽입하여 부분방전을 발생시켜 자체 설계 개발된 UHF 내장형 센서를 이용하여 검출하였다. 새로이 제안하는 방법과 기존의 PRPD 방법의 인식률을 상호 비교하기 위하여, 두 가지 그룹을, 즉, 기존의 방법에 의한 것과 부분방전의 주파수 분석이 포함된 방법에 의한 데이터그룹을 구축하고 학습방법은 동일한 인공신경망 MLP (Multilayer Perceptron)를 이용하여 인식률과 학습시간을 동시에 비교하였다. 상호 비교 결과에 의하면, 후자의 방법이 인식확률 뿐만아니라 학습시간도 좋은 결과가 나타났다.

  • PDF