가스절연 개폐장치의 PD검출용 UHF 대역 외장형 센서 제작 및 감도 특성 (Development of External UHF PD Sensor for the Detection of Partial Discharge in $SF_6$ Gas-insulated Switchgear)

  • 이창용;홍철용;최병화;윤자홍;남극채;정재기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1799-1801
    • /
    • 2004
  • We have developed the external-type PD sensors for detecting of the electromagnetic waves up to ultra high frequency (UHF) bands, propagating in various type of GIS. Sufficiently high sensitivity and accuracy for practical use were achieved for the external PD sensor. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

다중결함 부분방전의 패턴특성 연구 (A Study on Pattern Characteristics of Multi-Defect Partial Discharge)

  • 이준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.970-972
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produces from these defect simultaneously. Regarding these situations, we have to discriminate the type of defect as well as to determine whether the PD occurs or not. In our research. some analysis results of the PD signals from multi-defects insulating system will be presented. We measure the PD signals using three kind of electrode system: IEC(b). Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combine two electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods will be tested, and the possibilities and limitations of each method will be clarified.

  • PDF

송전 XLPE 케이블 절연층을 이용한 전기트리 형성과 부분방전 양상의 상관관계 (A study on the correlation between the PD pattern and the formation of electrical trees by use of XLPE insulation for the underground power transmission cable)

  • 이전선;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2051-2053
    • /
    • 1999
  • In this work, PD patterns and electrical trees are observed by use of the XLPE cable insulation. and the tree initiation voltage related to the contamination are also measured in order to calculate the electric stress necessary for the design of cable insulation. Throughout these works, correlation between the PD pattern and the shape of electrical tree has been observed that there may exist three distinct pattern of PD dependence on the stage of tree propagation, Such correlation could bring a basic information in connection with the partial discharge of cable system. It was also found that the electrical stress necessary for the initiation of electrical tree was measured to the 290kV/mm for the 154kV XLPE cables manufactured in KOREA.

  • PDF

반도전 입자를 갖는 PET film내에서의 PD Pattern 분석 (Analysis PD Pattern in PET film with semiconductor particle)

  • 최필문;정병선;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2399-2401
    • /
    • 1999
  • This paper indicate that phase resolved partial discharge pattern are investigated on PET films with semiconductor particle. In this study, we measured phase-resolved PD pattern and statistical parameter from PET specimens according to containing semiconductor particle. Measurement system is the conventional PD detector using digital signal processing technique. The relationship of semiconductor particle in PET film was discussed through the difference of $\psi$-q-n distribution and statistical analysis.

  • PDF

A Study on the Partial Discharge Patterns from Multi-Defect Insulating Systems

  • Lee, June-Ho;Tatsuki Okamoto
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.170-173
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produced from these defects simultaneously. Regarding these situations, we have to discriminate the type of defect as well as determine whether the PD occurs or not. In this paper, some analysis results of the PD signals from multi-defects insulating system were presented. We measure the PD signals by using three kind of electrode system, IEC(b), Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combined to electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods were tried, and the possibilities and limitations of each method were clarified.

  • PDF

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

가스절연기기에서 외장형 PD 센서를 이용한 부분방전 검출 (Detection of Partial Discharge in $SF_6$ Gas-insulated Switchgear Using External UHF PD sensors)

  • 이창용;홍철용;최병화;윤자홍;남극채;정재기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.125-127
    • /
    • 2004
  • We have developed the external-type PD sensors for detecting of the ultra high frequency (UHF) signals in various type of GIS. Sufficiently high sensitivity and accuracy for practical use were achieved for the PD sensor. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

고온 초전도 레이블의 절연 특성 (Insulation Characteristics of High Temperature Superconducting Cable)

  • 김해준;김재호;심기덕;김해종;조전욱;성기철;곽동순;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF

UHF 부분방전 진단법에 의한 가스절연 개폐장치의 성능검증 (Performance Verification of the Gas Insulated Switchgear using UHF Partial Discharge Diagnosis Method)

  • 김정배;정재룡;김민수;송원표;김맹현;고희석;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.132-135
    • /
    • 2004
  • In generally, compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise. We can detect the real abnormality with several pC in GIS using UHF method. Recently, it has applied to use the external UHF sensor attached on spacer to GIS of existing substation. In this paper, we firstly described the technique of the partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity, the relationship of dBm-pC and diagnosis of the reason of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on 800kV GIS in domestic substation. rge diagnosis of GIS.

  • PDF