Bio-Inspired Surface Modification of 3-Dimensional Polycaprolactone Scaffold for Enhanced Cellular Behaviors

  • Jo, Seon-Ae;Gang, Seong-Min;Park, Su-A;Lee, Hae-Shin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.202-202
    • /
    • 2011
  • The research of 3-dimensional (3-D) scaffold for tissue engineering has been widely investigated as the importance of the 3-D scaffold increased. 3-D scaffold is needed to support for cells to proliferate and maintain their biological functions. Furthermore, its architecture defines the shape of the new bone and cartilage growth. Polycaprolactone (PCL) has been one of the most promising materials for fabricating 3-D scaffold owing to its excellent mechanical property and biocompatibility. However, there are practical problems for using it, in vitro and in vivo; extracellular matrix components and nutrients cannot penetrate into the inner space of scaffold, due to its hydrophobic property, and thus cell seeding and attachment onto the inner surface remain as a challenge. Thus, the surface modification strategy of 3-D PCL scaffold is prerequisite for successful tissue engineering. Herein, we utilized a mussel-inspired approach for surface modification of 3-D PCL scaffold. Modification of 3-D PCL scaffolds was carried out by simple immersion of scaffolds into the dopamine solution and stimulated body fluid, and as a result, hydroxyapatite-immobilized 3-D PCL scaffolds were obtained. After surface modification, the wettability of 3-D PCL scaffold was considerably changed, and infiltration of the pre-osteoblastic cells into the 3-D scaffold followed by the attachment onto the surface was successfully achieved.

  • PDF

Effect of Biodegradable Polymer Coating on the Corrosion Rates and Mechanical Properties of Biliary Magnesium Alloy Stents (생분해성 고분자 코팅이 담관용 마그네슘 합금 스텐트의 분해 속도와 기계적 물성에 미치는 영향)

  • Kim, Hyun Wook;Lee, Woo-Yiel;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.36-43
    • /
    • 2020
  • A biliant stent was fabricated using a magnesium alloy wire, a biodegradable metal. In order to control the fast decomposition and corrosion of magnesium alloys in vivo, magnesium alloy wires were coated with biodegradable polymers such as polycaprolactone (PCL), poly(propylene carbonate) (PPC), poly (L-lactic acid) (PLLA), and poly (D, L-lactide-co-glycolide) (PLGA). In the case of PPC, which is a surface erosion polymer, there is no crack or peeling compared to other polymers (PCL, PLLA, and PLGA) that exhibit bulk erosion behavior. Also, the effect of biodegradable polymer coating on the axial force, which is the mechanical property of magnesium alloy stents, was investigated. Stents coated with most biodegradable polymers (PCL, PLLA, PLGA) increased axial forces compared to the uncoated stent, reducing the flexibility of the stent. However, the stent coated with PPC showed the axial force similar to uncoated stent, which did not reduce the flexibility. From the above results, PPC is considered to be the most efficient biodegradable polymer.

Development of Conductive Polycaprolactone (PCL)-resin based on Reduced Graphene Oxide(rGO)/Polypyrrole (Ppy) composite for 3D-printing application (3D 프린팅 응용을 위한 환원그래핀/폴리피롤 복합체 기반의 전도성 폴리카프로락톤 레진의 개발)

  • Jeong, Hyeon Taek;Jung, Hwa Yong;Cho, Young Kwang;Kim, Chang Hyeon;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.935-939
    • /
    • 2018
  • 3D Printing technology is developing in various prototypes for medical treatment, food, fashion as well as machinery and equipment parts production. 3D printing technology is also able to fully be utilized to other industries in terms of developing its technology which has been reported in many field of areas. 3D printing technology is expected to be used in various applications related to $4^{th}$ industrial revolution such as finished products and parts even it is still carried out in the prototype model. In this study, we have investigated and developed conductive resin for 3d printing application based on reduced graphene oxide(rGO)/Polypyrrole(Ppy) composite and polycaprolactone(PCL) as a biodegradable polymer. The electrical properties and surface morphology of the conductive PCL resin based on therGO/Ppy composite were analyzed by 4point-probe and scanning electron microscope(SEM). The conductive PCL resin based on rGO/Ppy composite is expected to be applicable not only 3D printing, but also electronic materials in other industrial fields.

Effects of three-dimensionally printed polycaprolactone/β-tricalcium phosphate scaffold on osteogenic differentiation of adipose tissue- and bone marrow-derived stem cells

  • Park, Hannara;Kim, Jin Soo;Oh, Eun Jung;Kim, Tae Jung;Kim, Hyun Mi;Shim, Jin Hyung;Yoon, Won Soo;Huh, Jung Bo;Moon, Sung Hwan;Kang, Seong Soo;Chung, Ho Yun
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.181-189
    • /
    • 2018
  • Background: Autogenous bone grafts have several limitations including donor-site problems and insufficient bone volume. To address these limitations, research on bone regeneration is being conducted actively. In this study, we investigate the effects of a three-dimensionally (3D) printed polycaprolactone (PCL)/tricalcium phosphate (TCP) scaffold on the osteogenic differentiation potential of adipose tissue-derived stem cells (ADSCs) and bone marrow-derived stem cells (BMSCs). Methods: We investigated the extent of osteogenic differentiation on the first and tenth day and fourth week after cell culture. Cytotoxicity of the 3D printed $PCL/{\beta}-TCP$ scaffold was evaluated by 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium assay, prior to osteogenic differentiation analysis. ADSCs and BMSCs were divided into three groups: C, only cultured cells; M, cells cultured in the 3D printed $PCL/{\beta}-TCP$ scaffold; D, cells cultured in the 3D printed $PCL/{\beta}-TCP$ scaffold with a bone differentiation medium. Alkaline phosphatase (ALP) activity assay, von Kossa staining, reverse transcription-polymerase chain reaction (RT-PCR), and Western blotting were performed for comparative analysis. Results: ALP assay and von Kossa staining revealed that group M had higher levels of osteogenic differentiation compared to group C. RT-PCR showed that gene expression was higher in group M than in group C, indicating that, compared to group C, osteogenic differentiation was more extensive in group M. Expression levels of proteins involved in ossification were higher in group M, as per the Western blotting results. Conclusion: Osteogenic differentiation was increased in mesenchymal stromal cells (MSCs) cultured in the 3D printed PCL/TCP scaffold compared to the control group. Osteogenic differentiation activity of MSCs cultured in the 3D printed PCL/TCP scaffold was lower than that of cells cultured on the scaffold in bone differentiation medium. Collectively, these results indicate that the 3D printed PCL/TCP scaffold promoted osteogenic differentiation of MSCs and may be widely used for bone tissue engineering.

The Effect of BSA on the Release of Cefadroxil from a Polycaprolactone Matrix (폴리카프로락톤 매트릭스로부터 세파드록실의 방출에 미치는 BSA의 영향)

  • Kim, Seung-Ryul;Jung, Yun-Jin;Kim, Young-Mi;Lee, Chi-Ho;Kim, Dae-Duk
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.363-368
    • /
    • 2004
  • In order to investigate the effect of bovine serum albumin (BSA), as a pore former, on the controlled release of an antibiotic from a biodegradable polymeric device, polycaprolactone (PCL)-cefadroxil matrices were prepared by the solvent casting method. The amount of cefadroxil released from various formulations at $37^{\circ}C$ was measured by HPLC. The duration of antimicrobial activity of matrices against S. aureus was evaluated by measuring the diameters of the inhibition zone. The morphology of the matrices was investigated by scanning electron microscopy (SEM). The release rate and extent of cefadroxil from PCL matrix increased as the loading dose and particle size of BSA/cefadroxil mixture powder increased. Cefadroxil released from the matrix exhibited antibacterial activity for up to 4 days. SEM of the cross-section of matrix showed the typical channel formation after 3 days of release study. Thus, a biodegradable polymeric matrix loaded with antibiotic/BSA mixture can effectively prevent bacterial infection on its surface, thereby bringing about an enhancement of biocompatibility of biomaterials.

Assembly of Gold Nanoparticles on Electrospun Polymer Nanofiber Film for SERS Applications

  • Wang, Li;Sun, Yujing;Wang, Jiku;Li, Zhuang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.30-34
    • /
    • 2014
  • We report a novel approach for fabricating active surface-enhanced Raman scattering (SERS) substrate for sensitive detection. This approach is based on the assembling of gold nanoparticles (AuNPs) onto the electrospun polycaprolactone (PCL) nanofiber film. The hydrophobic surface of PCL nanofiber film was pretreated using UV-inducing graft polymerization with acrylic acid. Afterwards this PCL nanofiber film was incubated with the AuNP solution to promote the assembly of AuNPs onto the PCL nanofibers and the formation of SERS active substrate. 4-aminothiophenol (4-ATP) molecule was used as a test probe for SERS experiments, indicating that the substrate has high sensitivity to SERS response. Our method has great advantage in term of environment-friendly synthesis, large-scale, high stability and good reproducibility. This highly active SERS substrate can be employed to detect the drug molecule, 2-thiouracil.

Evaluation of Bilayer Polycaprolactone Scaffold for Osteochondral Regeneration in Rabbits

  • Park, Min-hyeok;Hwang, Ya-won;Jeong, Do-Sun;Kim, Gon-hyung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.332-339
    • /
    • 2016
  • Polycaprolactone (PCL) scaffold have been developed as an alternative to natural donor tissue to repair a large osteochondral defect. The objective of this study is to evaluate efficacy and biocompatibility of bilayer PCL scaffold implanted for osteochondral repair in rabbit. Twenty-two male New Zealand White rabbits were used in this animal experiment. Rabbits were divided into three groups. Experimental surgery was carried out under general anesthesia. Osteochondral defects (5 mm diameter and 5 mm deep) were made in the center of the patellar groove using a 5 mm diameter biopsy punch. In group I (3D plotting) and group II (salt-leaching), the scaffold was implanted using the press-fitted technique into the defect. In control group, after osteochondral defect was created, the defect was left without implant. After four and eight weeks, rabbits were sacrificed and the defects were evaluated by macro -and microscopical methods. There were not found animal death and severe inflammatory evidence during the experimental periods. There were no significant differences between the experimental groups in gross evaluation. However the group I scored significantly higher than group II at 8 weeks in histological evaluation (P < 0.05). The 3-D plotting PCL scaffold was more suitable method for reconstruction of osteochondral defect than a salt-leaching PCL scaffold.

Biotin-Conjugated Block Copolymeric Nanoparticles as Tumor-Targeted Drug Delivery Systems

  • Kim, So-Yeon;Cho, Seung-Hea;Lee, Young-Moo
    • Macromolecular Research
    • /
    • v.15 no.7
    • /
    • pp.646-655
    • /
    • 2007
  • To achieve targeted drug delivery for chemotherapy, a ligand-mediated nanoparticulate drug carrier was designed, which could identity a specific receptor on the surfaces of tumor cells. Biodegradable poly(ethylene oxide)/poly$({\varepsilon}-caprolactone)$ (PEG/PCL) amphiphilic block copolymers coupled to biotin ligands were synthesized with a variety of PEG/PCL compositions. Block copolymeric nanoparticles harboring the anticancer drug paclitaxel were prepared via micelle formation in aqueous solution. The size of the biotin-conjugated PEG/PCL nanoparticles was determined by light scattering measurements to be 88-118 nm, depending on the molecular weight of the block copolymer, and remained less than 120 nm even after paclitaxel loading. From an in vitro release study, biotin-conjugated PEG/PCL nanoparticles containing paclitaxel evidenced sustained release profiles of the drug with no initial burst effect. The biotin-conjugated PEG/PCL block copolymer itself evidenced no significant adverse effects on cell viability at $0.005-1.0{\mu}g/mL$ of nanoparticle suspension regardless of cell type (normal human fibroblasts and HeLa cells). However, biotin-conjugated PEG/PCL harboring paclitaxel evidenced a much higher cytotoxicity for cancer cells than was observed in the PEG/PCL nanoparticles without the biotin group. These results showed that the biotin-conjugated nanoparticles could improve the selective delivery of paclitaxel into cancer cells via interactions with over-expressed biotin receptors on the surfaces of cancer cells.

Fabrication of Nanofiber-Combined 3D Scaffolds using Dual-Head Deposition Technology (듀얼헤드 적층 기술을 이용한 나노섬유로 결합된 3D 인공지지체 제작)

  • Sa, Min-Woo;Lee, Chang-Hee;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.108-115
    • /
    • 2018
  • In bone tissue engineering, polycaprolactone (PCL) is one of the most widely used biomaterials to manufacture scaffolds as a synthetic polymer with biodegradability and biocompatibility. The polymer deposition system (PDS) with four axis heads, which can dispense bio-polymers, has been used in scaffold fabrication for tissue engineering applications. A dual-head deposition technology of PDS is an effective technique to fabricate 3D scaffolds. The electrospinning technology has been widely used to fabricate porous and highly interconnected polymer fibers. Thus, PDS can fabricate nanofiber-combined hybrid scaffolds using fused deposition modeling (FDM) and electrospinning methods. This study aims to fabricate nanofiber-combined scaffolds with uniform nanofibers using PDS. The PCL nanofibers were fabricated and evaluated according to the fabrication process parameters. PCL nanofibers were successfully fabricated when the applied voltage, tip-to-collector distance, flow rate, and solution concentration were 5 kV, 1 cm, 0.1 ml/h, and 8 wt%, respectively. The cell proliferation was evaluated according to the electrospinning time. Scanning electron microscopy was used to acquire images of the cross-sectioned hybrid scaffolds. The cell proliferation test of the PCL and nanofiber-combined hybrid scaffolds was performed using a CCK-8 assay according to the electrospinning time. The result of in-vitro cell proliferation using osteosarcoma MG-63 cells shows that the hybrid scaffold has good potential for bone regeneration.

Biodegradable implants for orbital wall fracture reconstruction

  • Jang, Hyeon Uk;Kim, So Young
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2020
  • Background: Due to the different handling properties of unsintered hydroxyapatite particles/poly-L-lactic acid (uHA/PLLA) and polycaprolactone (PCL), we compared the surgical outcomes and the postoperative implantation accuracy between uHA/PLLA and PCL meshes in orbital fracture repair. Methods: Patients undergoing orbital wall reconstruction with PCL and uHA/PLLA mesh, between 2017 and 2019, were investigated retrospectively. The anatomical accuracy of the implant in bony defect replacement and the functional outcomes such as diplopia, ocular motility, and enophthalmos were evaluated. Results: No restriction of eye movement was reported in any patient (n= 30 for each group), 6 months postoperatively. In the PCL group, no patient showed diplopia or enophthalmos, while the uHA/PLLA group showed two patients with diplopia and one with enophthalmos. Excellent anatomical accuracy of implants was observed in 27 and 22 patients of the PCL and uHA/PLLA groups, respectively. However, this study showed that there were neither any significant differences in the surgical outcomes like diplopia and enophthalmos nor any complications with the two well-known implants. Conclusion: PCL implants and uHA/PLLA implants are safe and have similar levels of complications and surgical outcomes in orbital wall reconstruction.