• Title/Summary/Keyword: PC room

Search Result 232, Processing Time 0.023 seconds

A Study on the Development of Building Control and management System -Focusing on the Lighting Control and Monitoring system- (빌딩 제어 및 관리 시스템 개발에 관한 연구 -조명 제어 관리 시스템 구축을 중심으로-)

  • Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.110-118
    • /
    • 2007
  • Technology has been viewed at various stages of civilization as leading to future progress. The building, its services systems and management of the work process all contribute to the well-being of people within an organization. Productivity relies on there being a general sense of high morale and satisfaction with the workplace. Now buildings are considered as providing a milieu for human creativity. Flexibility, adaptability, service integration and high standards of finishes offer an intelligence threshold. Building Automation System(BAS) - controlled lighting systems may offer incremental energy saving. Conventional Lighting control systems often control equipment in a single room or over the limited area, because they are centralized control systems, which means that all the controlled circuits must be wired to a single control panel. The computers used by these systems are typically dedicated microprocess that perform only lighting control functions. By comparison, modern Building automation systems are distributed control system, which means that their computing hardware and software are distributed as a network that microprocessor-based control modules and standard PC. PLC(Programmable Logic controller) is extensible virtually without limits, so that all the lighting in a facility can be controlled by single, unified system - the same system that also can control and monitor the building's HVAC, security, and manufacturing processed, elevators, and more. A Building automation system can control light using schedules, manual controls, occupancy sensors, and photosensors, either singly or in combination. Building Lighting control and monitoring system will be for a energy saving and efficient building management system.

Growth and photocurrent properties for the $AgInS_{2}$ epilayers by hot wall ep itaxy (Hot wall epitaxy 방법에 의한 $AgInS_{2}$ 박막의 성장과 광전류특성)

  • Hong, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.92-96
    • /
    • 2002
  • A silver indium sulfide $(AgInS_{2})$ epilayer was grown by the hot wall epitaxy method, which has not been reported in the literature. The grown $AgInS_{2}$ epilayer has found to be a chalcopyrite structure and evaluated to be high quality crystal. From the photocurrent measurement in the temperature range from 30 K to 300 K, the two peaks of A and B were only observed, whereas the three peaks of A, B, and C were seen in the PC spectrum of 10 K. These peaks are ascribed to the band-ta-band transition. The valence band splitting of $AgInS_{2}$ was investigated by means of the photocurrent measurement. The crystal field splitting, $\Delta_{cr}$, and the spin orbit splitting, $\Delta_{so.}$ have been obtained to be 0.150 eV and 0.009 eV at 10 K, respectively. And, the energy band gap at room temperature has been determined to be 1.868 eV. Also, the temperature dependence of the energy band gap, $E_{g}(T)$, was determined.

  • PDF

Growth and Photocurrent Properties for the AgInS2 Epilayers by Hot Wall Epitaxy (Hot wall epitaxy방법에 의한 AgInS2 박막의 성장과 광전류 특성)

  • Kim, H.S.;Hong, K.J.;Jeong, J.W.;Bang, J.J.;Kim, S.H.;Jeong, T.S.;Park, J.S.
    • Korean Journal of Materials Research
    • /
    • v.12 no.7
    • /
    • pp.587-590
    • /
    • 2002
  • A silver indium sulfide ($AgInS_2$) epilayer was grown by the hot wall epitaxy method, which has not been reported in the literature. The grown $AgInS_2$ epilayer has found to be a chalcopyrite structure and evaluated to be high quality crystal. From the photocurrent measurement in the temperature range from 30 K to 300 K, the two peaks of A and B were only observed, whereas the three peaks of A, B, and C were seen in the PC spectrum of 10 K. These peaks are ascribed to the band-to-band transition. The valence band splitting of $AgInS_2$ was investigated by means of the photocurrent measurement. The crystal field splitting, $\Delta_{cr}$ , and the spin orbit splitting, $\Delta_{so}$ , have been obtained to be 0.150 eV and 0.009 eV at 10 K, respectively. And, the energy band gap at room temperature has been determined to be 1.868 eV. Also, the temperature dependence of the energy band gap, $E_{g}$(T), was determined.d.

A study on Medical servicer satisfaction of Emergency Department patient (응급실 내원자의 의료서비스 만족에 관한 연구)

  • Kwon, Seon Suk;Yoo, In Soo;Jung, Ha Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.1 no.1
    • /
    • pp.42-53
    • /
    • 1997
  • To offer basic data about the influential factors on patient's Satisfaction level for emergency medical services the authors were performed this study in 60 patients visited to emergency room of third stage general hospital in Taejeon city. Data were collected through interview with patients by using a 15 items' questionaire according to care subscale, teaching subscale of Likert's five stage quantitative scale and the tools developed by Barbara Davis. The data were analyzed by using the SPSS/PC computerized program for mean, standard deviation, percentage, ANOVA, t-test, and pearson correlation. The results are as followings ; 1. Satisfaction of emergency medical service were showed in care area, but not showed in teaching and total area 2. Satisfaction of sociodemographic characteristics were a statistically significant difference only marriage, that were the higher in marriaged than single(P<.0.05). 3. In the emergency situation characteristics the satisfaction accordings to the visit cause were lower in accident than disease group, the reason of hospital selection were in order trust, introduction group, distance, traffic, kinds, and score of satisfaction were showed each of 43.47, 51.27(P<.001), the transportation vehicle was the 119, hospital ambulance group. but were not a satistically significant difference. 4. The negative correlation was observed between satisfaction and the length of stay at ER and the longer length of stay at ER was showed the lower satisfaction. But the positive correlation was observed between satisfacton and the arrival time, patients who arrived ER from 6:00P.M. to midnight were more satisfied than patients who arrived other time. 5. The length of stay at ER was significantly different according to the reason of hospital selection, the reason of ER selection, the visitant cause and hopital decisioner. Especially the length of stay was much longer in accident group and unconscious group.

  • PDF

Design of Electrostatic Monitoring System (정전기 모니터링 시스템 설계)

  • Kim, Kang-Chul;Byon, Chi-Nam;Lim, Chang-Gyoon;Han, Seok-Bung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2069-2076
    • /
    • 2008
  • In this paper, we develop an electrostatic monitoring system which is composed of an electrostatic prediction system and a warning message transmission system. The electrostatic prediction system in a factory receives the value of electrostatic charge from the electrostatic sensor and predicts the next value by using past data and sends the value to the warning message transmission system through the bluetooth communication. The warning message transmission system gets a warning signal and transmits the warning message to the worker's cellphone through a commercial SMS web by a socket program running on Windows PC in a control room. We propose electrostatic forecasting algorithms based on LSR(least square regression) using weight factors in an electrostatic prediction system. Simulation results show that the algorithm with dynamically variable weight factors is best with 64.69V standard deviation and a warning message transmitted by the warning message transmission system is displayed on cellphone after about 5 seconds.

Synthesis and electrochemical performance of transition metal-coated carbon nanofibers as anode materials for lithium secondary batteries

  • Choi, Jin-Yeong;Hyun, Yura;Park, Heai-Ku;Lee, Chang-Seop
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.161-167
    • /
    • 2018
  • In this study, transition metal coated carbon nanofibers (CNFs) were synthesized and applied as anode materials of Li secondary batteries. CNFs/Ni foam was immersed into 0.01 M transition metal solutions after growing CNFs on Ni foam via chemical vapor deposition (CVD) method. Transition metal coated CNFs/Ni foam was dried in an oven at $80^{\circ}C$. Morphologies, compositions, and crystal quality of CNFs-transition metal composites were characterized by scanning electron microscopy (SEM), Raman spectroscopy (Raman), and X-ray photoelectron spectroscopy (XPS), respectively. Electrochemical characteristics of CNFs-transition metal composites as anodes of Li secondary batteries were investigated using a three-electrode cell. Transition metal/CNFs/Ni foam was directly employed as a working electrode without any binder. Lithium foil was used as both counter and reference electrodes while 1 M $LiClO_4$ was employed as the electrolyte after it was dissolved in a mixture of propylene carbonate:ethylene carbonate (PC:EC) at 1:1 volume ratio. Galvanostatic charge/discharge cycling and cyclic voltammetry measurements were taken at room temperature using a battery tester. In particular, the capacity of the synthesized CNFs-Fe was improved compared to that of CNFs. After 30 cycles, the capacity of CNFs-Fe was increased by 78%. Among four transition metals of Fe, Cu, Co and Ni coated on carbon nanofibers, the retention rate of CNFs-Fe was the highest at 41%. The initial capacity of CNFs-Fe with 670 mAh/g was reduced to 275 mAh/g after 30 cycles.

VR Theme Park Regulatory Improvement Plan (VR 테마파크 규제개선방안)

  • Song, Seung-Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.12
    • /
    • pp.1653-1658
    • /
    • 2018
  • This study aims to analyze the cases of VR space to improve the regulations. The space is divided according to the multi-use business act when the VR simulator and the VR game are simultaneously installed in a single space. It is necessary to amend the rules of the Tourism Promotion Act so that it can operate at a certain area of the youth game room subject to the Game Industry Law. Amendments that do not compartmentalize a space partition in the Multi-use Business Act should be carried out simultaneously. This is safer alternative by collective management rather than by the safety applied within a limited space by eliminating the compartment by industry. This is a legal amendment that allows VR simulator and VR game to be operated in the same space even in small sized amusement facilities such as other amusement facilities. This regulatory improvement plan is expected to help the activation of small sized VR theme parks.

A Study on Implications and Planning Directions for the Development of a Modular Airborne Infection Isolation Ward (모듈러 음압병동 개발을 위한 시사점 및 계획방향에 관한 연구)

  • Choi, Kwangseok;Yun, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.3
    • /
    • pp.7-16
    • /
    • 2022
  • Purpose: This study aims to establish the basic directions of the modular airborne infection isolation(AII) ward. Considering a specific function and purposed use as a modular AII ward, it is a chance to derive an address of current modular technology by overview the limitation and improvement of the existing modular architecture. Methods: In addition to the literature analysis on the configuration system of mobile hospitals, research cases on the operational effectiveness of the domestic and foreign mobile construction systems are analyzed. Results: In order to meet the various and strict space guidelines of the AII ward and a chance to improve limitations of uniformed existing modulars, AII modular the negative pressurized care setting should be minimized a structural restriction for reflecting its system on a architectural plan. For this unique requirements, it could be possible to apply various space boxes called infill box which needs to secure a large-scale space. So, a rahmen structure system could be adaptable for this purpose. A dead space between beams of the rahmen structure is to be used for MEP installation. Partial separation, dismantling, and repair should be possible by separating the MEP and infill box from the structure. The infill box must keep 3.5m width under the current Road Traffic Act. Implications: It is necessary to utilize and develop an improved construction method that can reduce the problems of existing steel modular and PC modular.

Growth and electro-optical characteristics of CdSe/GaAs epilayers prepared by electron beam epitaxy (전자빔 증착법에 의한 CdSe/GaAs epilayer의 성장과 그 전기-광학적 특성)

  • Yang, D.I.;Shin, Y.J.;Lee, C.H.;Choi, Y.D.;Yu, P.R.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.1
    • /
    • pp.70-75
    • /
    • 1997
  • An improved technique based upon an electron beam evaporation system has been developed to prepare cubic thin films In crystalline semiconductors. Zinc blonde CdSe epilayers were grown on GaAs(100) substrate by an e-beam evaporation method. The lattice parameter obtained from (400) reflection is $6.077\AA$, which is in excellent agreement with the value reported in the literature for zinc blonde CdSe. The orientation of the as-grown CdSe epilayer is determined by electron channeling patterns. The crystallinity of epitaxial CdSe layers were investigated on the double crystal X-ray rocking curve. The carrier concentration and mobility of epilayers deduced by Hall effect measurement are about $10^{18}{\textrm}{cm}^{-3}$, $10^2\textrm{cm}^2/V{\cdot}sec$ at room temperature, respectively. The photocurrent spectrum peak of the epilayer at 30 K exhibits a sharp change at 1.746 eV due to the free exciton of cubic CdSe.

  • PDF

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF