• Title/Summary/Keyword: PC room

Search Result 232, Processing Time 0.023 seconds

Urinary cotinine concentration by passive smoking in the PC game room (PC방에서의 간접흡연에 따른 요중 코티닌의 농도)

  • Park Yong Sun;Roh Youngman;Kim Chi Nyon
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.11-20
    • /
    • 2002
  • Tobacco smoke was confirmed as a human carcinogen by many research results. Because many adolescents stay long time in the PC game room, they are exposed to much of tobacco smoke. To evaluate the effect of passive smoking in the PC game room, airborne nicotine concentrations in 2 PC game rooms in Sung-nam city and urinary cotinine concentrations were measured for 20 adolescents. And the subjects were interviewed for duration and time in PC game room and smoking pattern. Subjects are composed of each of 10 smokers(5 males and 5 females) and 10 nonsmokers(5 males and 5 females). They stayed for three hours in the PC game room without smoking. Concentrations of nicotine in smokers and nonsmokers were 129.72 $\mu$g/$^3$ and 99.99 $\mu$g/m$^3$, respectively. Urinary cotinine concentrations were increased as time goes on after exposure to nicotine and showed maximum value at 9.45 hours after nicotine exposure and were 32.21 and 110.66 $\mu$g/L for nonsmoker and smokers. The more using time and frequency in PC game room, the higher urinary cotinine maximum concentration and the longer using duration, also the more increase urinary cotinine concentration. Urinary cotinine has a tendency to increase by passive smoking. Therefore, it is recommended that the effective control for indoor air quality and extensive research be needed to reduce nicotine concentration by passive smoking in the PC game room.

A Study on the Indoor Air Pollution of Singing Room and PC Room (노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구)

  • 이주상;원정일;이철민;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.67-74
    • /
    • 2002
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. Since most people spend a large majority of their time indoors, indoor air may affect human health more than outdoor air. This outline survey was carried out to investigate the extent of indoor air pollution in singing room and PC room. The concentrations of major indoor air pollutants(carbon dioxide, total suspended particulate, airborne microbes) and Thermocircumstance(temperature, relative humidity, intensity of illumination) were observed from October 1 to 31, 2001. As results of the survey, the mom values of thermocircumstance in singing room and PC room were $22.1^{\circ}C$ of temperature, 37.1% of humidity, 75 Lux of intensity of illumination and $22.0^{\circ}C$ of temperature, 52.6% of humidity, 135 Lux of intensity of illumination, respectively. The mean concentrations of carbon dioxide were 1589 ppm in singing room and 615 ppm in PC room, respectively The concentrations of carbon dioxide in singing room were higher than the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs. The mean concentrations of total suspended particulate were $0.33{\;}mg/\textrm{m}^3$ in singing room and $0.57{\;}mg/\textrm{m}^3$ in PC room respectively. The mean concentrations of airborne microbe were $16{\;}CFU/\textrm{m}^3$ in singing room and $12{\;}CFU/\textrm{m}^3$ in PC room, respectively.

A Study on PC using State and Demand of User's at Home (주거 내 PC사용공간의 사용실태 및 사용자의식에 관한 연구)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.143-146
    • /
    • 2005
  • The objective of this study is to provide new direction on house design in consideration of the user's life pattern. To this end, pc usage status at home, demand for pc using space, and requirements for pc room interior were analyzed. A survey was taken by parents and the SPSS win.10 was applied for analysis. The survey was conducted for 2 months, starting May 2004 to see the computer usage at home, demand and satisfaction for the computer's room. The results of this study were as follows; The oldest son or daughter in a family was the main user of the computer, posting 71%. 42percent of respondents said they used the pc in their son's and daughter's room while 36% answered living room. It reflects that the whole family want to use the pc in their sharing room, or for their children's convenience. Currently, inconvenience of space-related constraints for using the pc was not that high, which possibly stems from a lack of awareness of inconvenience in using the pc. However, the need for furniture and space for refreshment was suggested. Through this study, it is expected that new housing designs need to be made to reflect these requirements into interior design and building plan for user's convenience.

  • PDF

PC방에서의 간접흡연에 따른 요중 코티닌의 농도

  • 박용선;노영만;김치년
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.6-8
    • /
    • 2002
  • Many adolescents stay long time in the PC game room and are exposed to much of tobacco smoke. To evaluate the effect of passive smoking in the PC game room, airborne nicotine concentrations and urinary cotinine concentrations were measured for 20 adolescents at 2 PC game rooms in Sung-nam city. And the subjects were interviewed for duration and time in PC game room and smoking pattern. Subjects are composed of each of 10 smokers(5 males and 5 females) and 10 non-smokers(5 males and 5 females). They stayed for three hours in the PC game room without smoking. Concentrations of nicotine in smokers and non-smokers were 129.72 $\mu\textrm{g}$/㎥ and 99.99 $\mu\textrm{g}$/㎥, respectively. Urinary cotinine concentrations were increased as time goes on after exposure to nicotine and showed maximum value at 9.45 hours after nicotine exposure and were 32.21 and 110.66 $\mu\textrm{g}$/L for non-smoker and smokers. Urinary cotinine has a tendency to be increased by passive smoking. Therefore, it is recommended that the effective control for indoor air quality and extensive research be needed to reduce nicotine concentration by passive smoking in the PC game room.

  • PDF

Monitoring and Controlling of Systems in PC room using SNMP (SNMP를 이용한 PC 실습실 시스템의 모니터링과 제어)

  • Ahn, Seong-Jin;Chung, Jin-Wook
    • The Journal of Korean Association of Computer Education
    • /
    • v.3 no.1
    • /
    • pp.109-115
    • /
    • 2000
  • In this paper, we have designed the management System to monitor and control computers running on MS Windows in the PC room using SNMP. The proposed system has controlling capability to control the status of PC and monitoring functions to have real-time monitoring and process control. In the controlling system, it supports update and setting of the configuration information of PC and backup/restore the information when it happens to be some faults. In the monitoring system, it has monitoring the PC of students, controlling the process on PC, and invoking a new job. This system contributes to enhance the effectiveness of teacher's educational activities in PC room by controlling and monitoring the program running on student's computer.

  • PDF

PC-based Controller for Industrial Solid Freeform Fabrication System (산업용 SFFS (Solid Freeform Fabrication System)을 위한 PC 기반 제어기)

  • 박남수;황면중;이두용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.73-77
    • /
    • 2004
  • This paper presents a PC-based controller of industrial SFFS(Solid Freeform Fabrication System). The SFFS has multiple sub-controllers for the building room, the powder room, the temperature, and the density of oxygen in the chambers. Hence the main PC-based controller should effectively and timely send commands to the sub-controllers, and monitor the overall SLS process. The required actuators and sensors are selected to optimize the overall performance of the SFFS.

  • PDF

The Concentration of TSP and Heavy Metals in the Indoor Air of Local PC Rooms (지방 일개도시 PC방에서의 실내공기중 TSP농도와 TSP내 중금속 농도)

  • Cha Hyun Su
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.190-200
    • /
    • 2002
  • This study was carried out to investigate and analyze TSP of the PC rooms. The concentration of the total suspended particulate and heavy metals contained in the total suspended particulate of the 15 PC rooms located in one local city were measured. The statistical correlation coefficients between the total suspended particulate and factors of the indoor condition (number of fan or size of pc room, illumination), between the heavy metals and factors of the indoor condition were studied. The results are as follows: 1. The factors of the indoor condition of the 15 PC rooms are as follows. Average illumination was 24 luxes. Average number of computers installed were 37. Average number of the fans was 7. and the size of investigated PC rooms was $139.94m^2$. 2. The mean age of the subjects was 21.8 years old. they $(51.5\%)$ used the 15 pc rooms for fewer than 2 hours per one day. 3. The mean concentration of total suspended particulate (TSP) is lower in the evening ${139.085\;(2.462)\;{\mu}g/m^3}$ than the night ${166.216(2.609){\mu}g/m^3}$. 4. The mean concentration of total suspended particulate was industrial work area) residential area) commercial area. 5. The distribution of heavy metals were indicated as Zn>Cr>Pb>Cd in the indoor air at PC rooms. and the concentration rate of Zn was the highest among heavy metals. but this increase didn't show any relationship with many factors of indoor condition (number of fan or size of pc room, lighting) 6. The concentration of TSP & heavy metals didn't have any relationship between the factors of indoor environment (number of fans, size of pc room, lighting).

  • PDF

Transmission modes of Pneumocystis carinii among rats observed by karyotype analysis (핵형 추적에 의한 카리니주폐포자충의 전파 양상 확인)

  • 홍성태;류진숙
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.4
    • /
    • pp.283-288
    • /
    • 1992
  • To observe the transmission patterns of karyotype of Pneumocystis carinii (Pc) by rat colonies, three strains of rats, Sprague-Dawlcy(SD), Wistar(W) and Fisher (F) from various animal vendors, were suppressed of their immunity by injection of methyl prednisolone. They were kept for 5 to 13 weeks in 3 different animal rooms, A, B, and C. The purified organisms were prepared in low melting point agarose gel by embedded Iysis method for pulsed field gel electrophoresis. Field inversion gel electrophoresis showed 2 patterns of the kart·otype of Pc. The rooms A and C contained SD rats from the source p, and also the room A was used for F and W rats. However, Pc from all of the SD and F rats in the room A showed same karyotypes, the pattern I. The SD rats from difFerent vendors, M and 5, were reared in the room B, and shared the same Pc karyotypes, the pattern II . The rats of W strain were from the vendor M, and immune-suppressed in the animal room A. Five weeks after the expe- riment, the Pc showed the karyotype pattern II but the pattern became mixed with the type I after 7 to 8 weeks. The Bindings revealed that the animals born and reared in the same animal quarter harbored Pc with same karyotypes. If the animals were kept under immune-suppression in the same room with heavily infected hosts, they could be infected by Pc from their neighbors. The present experimental findings suggest that Pc is transmitted among rats through the air.

  • PDF

A Study on the Characteristics of PC Use Space and Users' Consciousness at Residences (주거 내 PC 사용공간의 특성 및 사용자 의식에 관한 조사연구)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.55-65
    • /
    • 2006
  • The objective of this study is to provide new direction on house design in consideration of the PC users' life pattern. This study found that PC use present conditions at home, demand for PC using space, and requirements for PC using area were analyzed. A survey was taken by 1108 residences, and the SPSS win.10 was applied for analysis. The survey was conducted to see the computer usage at home, demand and satisfaction for the PC using space. The results of this study were as follows; forty-seven percent of respondents said they used the PC in son's and daughter's room while 36.8% answered living room. It reflects that the whole family want to use the PC in the same area, or for their children's convenience. Users' consciousness was analyzed four factor, which were 'physical inconvenience:'satisfactions in PC position', 'inconvenience caused by narrowness', 'notion of privacy'. PC users' consciousness had significant differences in the satisfaction by PC users' characteristic and housing characteristic. It was to be classified that the PC use space into several pattern according to furniture arrangement, and channel pattern had the highest satisfaction among those pattern. Through this study, it is expected that new housing designs need to be made to reflect lese requirements into interior design and house plan for PC user's needs.

Room Temperature Fabrication of Organic Flexible Displays using Amorphous IZO Anode Film (비정질 IZO 애노드 박막을 이용한 유기물 플렉서블 디스플레이의 상온 제작)

  • Moon, Jong-Min;Bae, Jung-Hyeok;Jeong, Soon-Wook;Park, No-Jin;Kang, Jae-Wook;Kim, Han-Ki
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.687-694
    • /
    • 2006
  • We report on the fabrication of organic-based flexible displays using an amorphous IZO anode grown at room temperature. The IZO anode films were grown by a conventional DC reactive sputtering on the polycarbonate (PC) substrate at room temperature using a synthesized IZO target in a $Ar/O_2$ ambient. Both x-ray diffraction (XRD) and high resolution electron microscope (HREM) examination results show that the IZO anode film grown at room temperature Is complete amorphous structure due to low substrate temperature. A sheet resistance of $35.6\Omega/\Box$, average transmittance above 90 % in visible range, and root mean spare roughness of $6\sim10.5\AA$ were obtained even in the IZO anode film grown on PC substrate at room temperature. It is shown that the $Ir(ppy)_3$ doped flexible organic light emitting diode (OLED) fabricated on the IZO anode exhibit comparable current-voltage-luminance characteristics as well as external quantum efficiency and power efficiency to OLED fabricated on conventional ITO/Glass substrate. These findings indicate that the IZO anode film grown on PC substrate is a promising anode materials for the fabrication of organic based flexible displays.