• 제목/요약/키워드: P-graph.

검색결과 298건 처리시간 0.025초

A comparative study of pine rosin and glutaraldehyde cross linker on mechanical properties of jute corn starch based biocomposite

  • Karishma M. Sakhare;Suraj R. Bamane;Shashikant P. Borkar
    • Advances in materials Research
    • /
    • 제13권4호
    • /
    • pp.269-283
    • /
    • 2024
  • Biocompositesmade up of starch and jute fibres are biodegradable and environmentally friendly materials for sustainable development. In this study, corn starch has been separately modified with 15% pine rosin and 40% glutaraldehyde, and 30% glycerol is used as a plasticizer. The composites have been prepared for three different volume proportions of matrix and jute fibre such as 60:40, 70:30 and 80:20 by using a hot compression moulding machine. The effects of pine rosin and glutaraldehyde on mechanical properties have been studied. Pine rosin modified starch jute composites have shown higher tensile and flexural properties as compared with glutaraldehyde modified starch jute composite. The highest tensile strength and modulus are found at 60:40 matrix and jute fibre volume proportion of pine rosin modified starch jute composite which are 13.97 MPa and 782.94 MPa respectively. Similar trends were found in flexural strength and modulus for pine rosin modified starch jute composite having matrix to jute fibre proportion 60:40 which are 29.18 MPa and 1107.76 MPa respectively. But, in case of impact strength, glutaraldehyde modified starch jute composite having matrix to jute fibre proportion 80:20 have shown highest impact strength that is 59.05 KJ/m2. Starch-jute composite with glutaraldehyde shows 33% more water absorbency as compared to composite having pine rosin as cross linker. Highest FTIR graph indicates that the number of -OH group is much lower in case of pine rosin modified starch than glutatraldehyde modified starch which indicates that bonds formed by pine rosin are much stronger than the bonds formed by glutaraldehyde. The surface morphology of the composite was influenced by pine rosin and glutaraldehyde which is shown in the SEM image.

소아 신증후군 환자에서 Plasminogen Activator Inhibitor Type 1 유전자 다형성 (Plasminogen Activator Inhibitor Type 1 Gene Polymorphism in Patients with Minimal Change Nephrotic Syndrome)

  • 김영민;홍현기;김성도;조병수
    • Childhood Kidney Diseases
    • /
    • 제8권1호
    • /
    • pp.26-32
    • /
    • 2004
  • 목 적 : 소아 신증후군 환자에서 과응고성 경향을 가지고 있으며 Plasminogen activator inhibitor-1(PAI-1)은 강력하게 섬유소의 용해를 감소시키는 당단백으로 최근 몇몇 연구에 의하면 신증후군에서 증가된 PAI-1과 사구체내의 섬유소원이나 섬유소와 관련된 항체의 침착이 연관되어 있음을 시사하고 있다. 저자는 PAI-1 유전자 다형성 중에서 A-844 G 대립유전자 다형성의 빈도와 유전형을 소아의 신증후군에서 임상경과와의 연관성을 비교 평가하였다. 방 법 : 2001년 10월부터 2003년 1월까지 경희대학교 부속병원 동서신장병연구소에 방문한 146명의 신증후군 환아와 249명의 대조군을 대상으로 하였고 신증훈군 환아는 infrequent relapser(IR)와 frequent relapser(FR)로 다시 나누었다. 이들에 대해 PAI-1 promoter gene의 A-844 G에 대한 중합효소 연쇄반응-제한효소절편길이 다형현상(PCR-RFLP)을 이용하여 유전자형을 A/A, A/G, G/G로 분류하여 비교 분석하였다. 통계는 Graph Pad Prism 통계분석 소프트웨어 version 2.0을 사용하였고 95% 신뢰구간과 P value는 0.05보다 작은 것을 의미 있게 보았다. 결 과 : PAI-1 promoter gene의 A- 844G 다형성의 분포는 대조군애서 G/G 81(32.5%), A/A 42(16.9%), G/A 126(50.6%)이였고 신증후군 그룹 중 IR 그룹은 G/G 29(34.1%), A/A 15(17.7%), G/A 41(48.2%)이였으며 FR 그룹에서는 G/G 17(27.9%), A/A 18(29.5%), G/A 26(42.6%)이었다. 단지 PAI-1 gene의 A-844G의 다형성중 A/A 유전자형이 신증후군 환아 중 FR군에서만 대조군에 비하여 유의하게 증가하였다(16.9% vs 29.5%, OR=2.06, P=0.0251). 반면 A/G 유전자형(OR=0.73, P=0.2639)이나 G/G 유전자형(OR=0.80, P=0.4828)은 통계학적인 의의가 없었고 IR군에서 대조군에 비하여 A/A(OR=1.06, P=0.8690), A/G(OR=0.91, P=0.7063), G/G(OR=1.07, P=0.7880)으로 모두 통계학적으로 유의하지 않았다. 결 론 : A-844G AA 유전자형을 가진 신증후군 환자와 FR와 통계적인 상관관계가 있음을 알수 있었다. 이는 향후 PAI-1 유전자와 과응고성과 관련된 생화학적 검사와의 연관성에 대한 추가적인 조사와 특히, 신증후군의 과응고성과 신증후군 재발과의 연관성이 있는지에 관한 연구가 더 필요할 것으로 사료된다.

  • PDF

2-DDG가 FSa II 종양의 성장속도와 증식 능력, 신진대사에 미치는 영향 ; $^{31}P$-자기공명 분광기와 유세포 분석기를 이용한 연구 (Effects of 2-Deoxy-D-Glucose on Metabolic Status, Proliferative Capacity and Growth Rate of FSall Tumor: Observations made by In Vivo $^{31}P$-Nuclear Magnetic Resonance Spectroscopy and Flow Cytometry)

  • 장혜숙;최은경;조정길;임태환;이대근;이윤;조영주;김곤섭
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.1-6
    • /
    • 1991
  • 2-ODG가 쥐의 섬유육종(FSall)에 미치는 영향에 대한 연구로 에너지 신진대사는 체내에서의 $^{31}P$-자기공명 분광기를 이용하여 관찰하였고 세포 증식 능력은 유세포 분석기를 사용하여 연구하였다. 성장속도는 10개의 세포를 $C_3Hf/Sed$ 쥐의 발등에 이식한 후 3차원적으로 측정하여 관찰하였다. 2-DDG를 투여한 경우에는 이식후 12일에 복강내로 주사하였다. 이식후 12일의 종양의 평균 크기는 $250mm^3$이었다. Fsall종양의 성장속도는 semilog graph의 기울기와 종양의 doubling time으로 측정하였다. 2-DDG를 투여한 후 성장속도가 감속되었다. 5~12일 사이의 성장속도의 기울기가 0.828, 종양의 Idubling time이 0.84일이고 대조군에서는 13~28일 사이의 기울기가 0.218, doubling time이 3.2일인 반면 2-DOG 투여군에서는 성장속도의 기울기가 0.135이고 doubling time이 5.1일이었다. $^{31}P$-자기공명 분광기를 이용하여 2-DDG의 영향을 분석해 본 결과 2-DDG 투여후 종양증식 속도의 감속과 더불어 phosphornonester (PME)와 inorganic phosphate (Pi)의증가속도가 감소하였다. 이것은 2-DDG투여후 세포의 괴사가 감소하였다는 의미가 있다. 유세포 분석기를 이용하여 종양의 증식 능력을 분석한 결과는 2-DDG 투여후 5-phase와 G2+M phase의 DNA분포가 크게 증가하였다. 이것은 2-DDG투여후 세포가 좀더 방사선에 민감한 cycle로 진행함을 의미하는 것으로 해석할 수 있다. 이에 저자들은 2-DDG가 Fsall 종양세포에 미치는 흥미있는 결과를 토대로 방사선 치료에 미치는 영향과실제 이용 가능성에 대하여 더 연구하고자 한다.

  • PDF

"감자에 대한 항생제(抗生劑) 피마리신의 통계적(統計的) 효과(效果) 분석(分析)" (INVESTIGATION OF THE EFFECT OF AN ANTIBIOTIC "P" ON POTATOES)

  • 김종훈
    • 품질경영학회지
    • /
    • 제5권2호
    • /
    • pp.59-120
    • /
    • 1977
  • An antibiotic 'P', which is one of the products of the Gist Brocades N. V. is being tested by its research department as fungicide on seed-potatoes. For this testing they designed experiments, with two control groups, one competitor's product, eight formulations of the antibiotic to be tested in different concentrations and one mercury treatment which can not be used in practice. The treated potatoes were planted in three different regions, where bifferent conditions prevail. After several months the harvested potatoes are divided in groups according to their diameter, potato illness is analysed and counted. These data were summarised in percentage and given to us for Analysis. We approached and analysed the data by following methods: a. Computation of the mean and standard deviation of the percenage of good results in each size group and treatment. b. Computation of the experimental errors by substraction of each treatment mean from observed data. c. Description of the frequency table, plotting of a histogram and a normal curve on same graph to check normality. d. Test of normality paper and chi-sqeare test to check the goodness of fit to a normal curve. e. Test for homogeneity of variance in each treatment with the Cochran's test and Hartley's test. f. Analysis of Variance for testing the means by one way classifications. g. Drawing of graphs with upper and lower confidence limits to show the effect of different treatments. h. T-test and F-test to two Control mean and variance for making one control of Dunnett's test. i. Dunnett's Test and calculations for numerical comarision of different treatments wth one control. In region R, where the potatoes were planted, it was this year very dry and rather bad conditions to grow potatoes prevailed during the experimental period. The results of this investigation show us that treatment No.2, 3 and 4 are significantly different from other treatments and control groups (none treated, just like natural state). Treatment no.2 is the useless mercury formulation. So only No. 3 and 4, which have high concentrations of antibiotic 'P', gave a good effect to the potatoes. As well as the competitors product, middle and low concentrated formulations are not significantly different from control gro-ups of every size. In region w, where the potatoes got the same treatments as in region R, prevailed better weather conditions and was enough water obtainable from the lake. The results in this region showed that treatment No. 2, 3, 4, and 5 are Significantly different from other treatments and the control groups. Again No.2 is the mercury treatmentin this investigation. Not only high concentrated formulation of antibiotic 'P', but also the competitor's poroduct gave good results. But, the effect of 'P', was better than the competitors porduct. In region G, where the potatoes got the same treatments as in the regions R and w. and the climate conditions were equal to region R, the results showed that most of the treatments are not significantly different from the control groups. Only treatment no. 3 was a little bit different from the others. but not Significantly different. It seems to us that the difference between the results in the three regions was caused by certain conditions like, the nature of the soil the degres of moisture and hours of sunshine, but we are not sure of that. As a conclusion, we can say that antibiotic 'P' has a good effect on potatoes, but in most investigations a rather high concentration of 'P' was required in formulations.

  • PDF

래버린스 위어를 이용한 침사지 내 침전효율 개선 (Improvement of Sedimentation Rate in the Settling Basin by Labyrinth Weir)

  • 조훈식;여창건;임장혁;이승오
    • 대한토목학회논문집
    • /
    • 제32권3B호
    • /
    • pp.153-159
    • /
    • 2012
  • 본 연구에서는 기존의 침사지 내부 수공구조물(격벽)로 사용되고 있는 둔턱을 대체하여 일반형 사다리꼴 래버린스 위어 (generic labyrinth weir)와 변형된 형태인 경사형 마루 래버린스 위어(inclined crest labyrinth weir)를 제시하였으며, 래버린스 위어 적용시 발생하는 수리학적 흐름특성을 이용하여 침사지에서 침전율을 개선하고자 하였다. 본 연구에서는 전수두비 (headwater ratio) $H_t/P$, 와 확폭비(magnification ratio) L/W, 그리고 총 마루길이 당 유입유량 $q_L$을 침전효율의 주요 분석지표로 제시하였으며, 기존의 침사지 형상과 래버린스 위어를 적용한 래버린스 침사지 형상을 제작하여 실험을 수행하였다. 실험결과 래버린스 위어를 적용한 침사지는 확폭비 변화에 따른 전수두비의 변동이 침전효율(%)에 크게 영향을 미치는 것으로 분석되었으며, 래버린스 위어 반복배열수(N)가 2~4개 일 때 침전효율이 개선되는 것으로 분석되었다. 또한 회기분석을 통해 침전효율이 개선되는 유입조건 및 형상은 총 마루길이 당 유입유량이 $q_L{\geq}3.5cm^2/s$인 조건과 확폭비가 $L/W{\leq}3.5$ 인 경우 로 나타났으며, 이러한 침전효율이 개선되는 구간을 도표상으로 표현 및 분석하였다. 본 연구에서 제시한 분석지표를 통해 오탁수 유입량 및 침사지 소요면적 등 설계조건에 따른 적합한 침전효율을 갖는 구조적으로 최적화된 래버린스 침사지의 기초 설계에 활용될 수 있을 것이다.

밭토양에서 옥살릭산과 희석요인에 의한 자체 인산의 이동 특성 (Mobilization Characteristics of Indigenous Phosphate by Oxalic Acid and Dilution Factors in Upland Soils)

  • 정덕영;이교석
    • 한국토양비료학회지
    • /
    • 제39권1호
    • /
    • pp.46-51
    • /
    • 2006
  • 토양내에서 인의 축적은 농업과 환경에 심각한 문제로 대두되고 있다. 본 연구에서는 토양입자표면에 흡착된 인산이온의 치환방법을 조사하기 위하여 실험실 규모의 연구를 수행하였다. 토양시료는 충남 논산에 위치한 구릉지 밭토양 4개 지점에서 0-10 cm와 10-20 cm 깊이의 토양시료를 채취하였다. 인의 가용화를 조사하기 위하여 $10^{-5}$ to $10^{-1}cmol\;L^{-1}$의 옥살릭산을 1:1, 1:2.5, 1:5, 1:10 및 1:20의 희석비율로 처리하여 조사하였다. 인 가용화는 희석비율이 1:5 이하의 경우 옥살릭산의 농도가 $5{\times}10^{-4}cmol\;L^{-1}$ 이상으로 처리될 때 증가가 시작되었다. 그리고 희석비율이 1:10과 1:20 일 때 인가용화 시작점은 1:5 이하와 비교 시 $10^{-4}cmol\;L^{-1}$에서 $5{\times}10^{-5}cmol\;L^{-1}$로 낮아짐을 알 수 있었다. 본 연구에서 얻는 그래프의 곡선적정 결과 희석배수가 1:5 이하에서는 지수증가의 형태이나 1:10 이상의 경우 S자 만곡형으로 인의 가용화는 희석배수에 의해 많은 영향을 받는 것으로 조사되었다.

정상월경주기를 가진 20-30대 여성의 난소주기에 따른 피부저항변이도 연구 (A Study on Skin Resistance Variability(SRV) over the Period of Ovarian Cycle of Women in their 20's and 30's with Normal and Regular Menstrual Cycles)

  • 이재은;조현주
    • 대한한방부인과학회지
    • /
    • 제21권4호
    • /
    • pp.183-193
    • /
    • 2008
  • Purpose: To research the changes of Skin Resistance Variability(SRV) over the period of ovarian cycle of healthy young women with normal and regular menstrual cycles using Oriental Medical Diagnose Autonomic system-3000 (OMD-3000). Methods: We measured SRV of 15 women who were working at O O Oriental Hospital from July to Oct. 2008. Each woman took the OMD-3000 test 8 times during 2 menstrual cycles. Each cycle consists of 4 phases-follicular phase, ovulation, luteal phase and menstruation. We analyse the data by SPSS 12.0 for windows. the one-way ANOVA by Repeated Measure(p<0.05). Results: 1. (1) The Factor AA means at zone 1 were 0.77$\pm$0.40, at zone 2 were 1.07$\pm$0.68, at zone 3 were 0.77$\pm$0.35, at zone 4 were 0.68$\pm$0.32, at zone 5 were 0.74$\pm$0.29, at zone 6 were 0.85$\pm$0.30, and at zone 7 were 0.74$\pm$0.29. The Factor AA means were lower than normal range at zone 1,3,4,5,6 and 7. The graph pattern of M shape was caused by the Factor AA means at zone 2 and zone 6 were higher than others. (2) The Factor AA means at zone 1 and zone 3 show abnormal regulation state. 2. During the menstruation. the Factor AA means were higher at zone 1,2 and 3 than other zones. During the ovulation, the Factor AA means were higher at zone 4,5,6 and 7 than other zones. Especially at the menstruation phase in zone 2 and at the ovulation phase in zone 6 tend to be highest means than other phases respectively. 3. However there were no significant difference of means during 4 ovarian phases in 7 zones except ovulation phase to luteal phase at zone 4(p = 0.013). Conclusion: The results suggest that changes of SRV during 4 menstrual cycles are not variables in reading 7-zone-diagnostic system. Further study will be needed.

  • PDF

CRT를 이용한 하이래딕스 RSA 모듈로 멱승 처리기의 구현 (Implementation of High-radix Modular Exponentiator for RSA using CRT)

  • 이석용;김성두;정용진
    • 정보보호학회논문지
    • /
    • 제10권4호
    • /
    • pp.81-93
    • /
    • 2000
  • 본 논문에서는 RSA 암호 시스템의 핵심 연산인 모듈로 멱승의 처리속도를 향상시키기 위한 방법으로 하이래딕스 (High-Radix) 연산 방식과 CRT(Chinese Remainder Theorem)를 적용한 새로운 하드웨어 구조를 제안한다. 모듈로 멱승의 기본 연산인 모듈로 곱셈은 16진 연산 방법을 사용하여 PE(Processing Element)의 개수를 1/4고 줄임으로써, 기존의 이 진 연산 방식에 비해 클럭 수차 파이프라이닝 플립플롭의 지연시간을 1/4로 줄였다. 복호화시에는 합성수인 계수 N 의 인수, p, q를 알고 있는 점을 이용하여 속도를 향상시키는 일반적인 방법인 CRT 알고리즘을 적용하였다. 즉, s비트 의 키에 대해, s/2비트 모듈로 곱셈기 두 개를 병렬로 동시 수행함으로써 처리 속도를 CRT를 사용하지 않을 때보다 4 배정도 향상시켰다. 암호화의 경우는 두 개의 s/2비트 모듈로 곱셈기를 직렬로 연결하여 s/비트에 대한 연산이 가능하도록 하였으며 공개키는 E는 17비트까지의 지수를 허용하여 빠른 속도를 유지하였다. 모듈로 곱셈은 몽고메리 알고리즘을 변형하여 사용하였으며, 그 내부 계산 구조를 보여주는 데이터 종속 그래프(Dependence Graph)를 수평으로 매핑하여 1차원 선형 어레이 구조로 구성하였다. 그 결과 삼성 0.5um CMOS 스탠다드 셀 라이브러리를 근거로 산출한 때, 1024 비트 RSA 연산에 대해서 160Mhz의 클럭 주파수로 암호화 시에 15Mbps, 복호화 시에 1.22Mbs의 성능을 가질 것으로 예측되며, 이러한 성능은 지금가지 발표된 국내의의 어느 논문보다도 빠른 RSA 처리 시간이다.

물리실험에서 선개념과 불일치한 실험 데이터에 대한 학생들의 해석 유형 (The Types of Explanation about Different Experimental Data with Students' Preconceptions on Physical Experiment)

  • 변영찬;김지나
    • 한국과학교육학회지
    • /
    • 제27권5호
    • /
    • pp.404-411
    • /
    • 2007
  • 이 연구는 학생들에게 예상과 불일치한 실험 데이터를 제시한 뒤, 학생들이 이 데이터를 어떻게 해석하는가를 알아보는 것이다. P 대학교 대학생을 대상으로, 진자의 주기에 대해서 과학적 개념을 가지고 있는 학생 중, 깡통진자에 물을 넣어가면서 깡통진자의 주기를 측정할 때, 주기가 일정할 것이라고 예상한 학생 45명을 선발하였다. 학생들에게 깡통진자에 물을 넣어가면서 주기를 측정한 데이터를 제시하고, 표에 기록하게하고 그것을 그래프로 그려 자료변환을 하도록 하였다. 검사문항지를 통해 불일치 인식, 데이터에 대한 선뢰, 인지갈등, 개념 변화 및 실험 결과에 대한 가설 등을 조사하였다. 인지 갈등정도를 측정하기 위해 CCLT(Cognitive Conflict Levels Test) 검사문항지를 사용하였다. 일부 학생들은 선개념에 의존하여, 데이터를 실제 데이터가 아니라고 간주하거나 실험 오류로 간주하였다. 불일치 상황을 인식 한 학생들은 그렇지 않은 학생들에 비해 인지갈등 정도가 높았다. 선개념에 대한 신념이 변한 학생들은 불일치 상황을 인식하였고, 신념이 변하지 않은 학생들에 비해 인지갈등 정도가 높았다. 선개념에 대한 신념이 변하지 않은 학생들은 데이터를 실험 오류로 간주하였다.

골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로- (A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry)

  • 동경래;김호성;정운관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.17-23
    • /
    • 2008
  • 목적 : 골밀도검사의 중요한 부분을 차지하고 있는 검사장비 및 검사자의 정밀도와 정확도는 환경에 따라 차이가 있기 때문에 질 관리가 체계적으로 이루어져야 한다. 골밀도 검사장비의 노화 및 잦은 고장에 의하여 장비의 교체 및 추가 구입으로 인하여, 추적검사를 하는 환자들의 호환성에 문제가 있다. 따라서 장비 교체 및 증설 후 동일한 장비처럼 호환하여 시용해도 환자의 임상적인 골밀도 변화를 정확하고 정밀하게 반영할수 있는지 알아보고자 한다. 재료 및 방법 : 장비 정밀도는 GE Lunar Prodigy Advance 2 대의 장비 (P1, P2)와 HOLOGIC Spine Phantom(HSP)을 이용하여 각 장비에서 20 번씩 스캔하여 팬텀을 이용한 정밀도 데이터를 획득하였고 (Group 1), 여성 120명 (평균나이 48.78, $20{\sim}60$세)을 대상으로 각 장비에서 15명씩, 같은 환자가 두 번 촬영을 하여 각 검사자의 정밀도를 측정했다(Group 2), 또한 검사자의 정밀도는 팬텀(ASP)을 이용하여 매일 아침마다 질 관리 시행후 얻은은 데이터를 기준으로, 각각의 장비에서 HSP를 이용하여 각 장비에서 20번씩 스캔 후 데�歷� 획득하여 검사자정밀도 및교차 보정 데이터를 산출하였고(Group 3), 여성 120명(평균나이 48.78, $20{\sim}60$세)의 동일 환자를 대상으로 한 장비에서 한 번씩 교차로 측정하여 검사자 정밀도 및 교차보정 데이터를 산추라였다(Group 4). 결과 : Daily Q.C Data는 $0.996\;g/cm^2$, 변동계수(%CV) 0.08로 안정된 장비로서 Group 1에서 Mean${\pm}$SD 및 %CV값은 ALP(P1: $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2: $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). Group 2에서 Mean${\pm}$SD 및 %CV값은 P1: $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2: $1.198{\pm}0.002\;g/cm^2$, %CV=0.163, Group 3에서의 Mean${\pm}$2SD 및 %CV는 P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48), Group 4에서 Mean${\pm}$2SD 및 %CV는, r값은 spine: $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998이였다. 결론 : HOLOGIC Spine Phantom과 LUNAR ASP %CV는 ISCD에서 규정한 정상오차 범위인 ${\pm}2%$안에 모두 포함되었고 BMD가 비교적 일정한 값을 유지하면 측정되어 뛰어난 재현성을 보였다. 하지만 Phantom은 환자의 체중이나 체지방 조성의 변화 등 임상적인 부분을 반영하는 데는 한계성을 갖고 있어 mis-calibration을 check하는데 유용할 것으로 판단된다. Group 3과 Group 4의 결과에서 환자를 하나의 장비로 두 번 측정한 값을 보았을 때와 두 대의 장비를 교차하여 측정한 값 모두 2SD값 이내에 포함되었고 선형회귀분석(Regression Analysis) r값이 0.99 이상으로 높은 정밀도와 상관도를 나타냄으로써 두 장비를 호환하여 추적검사를 시행하여도 영향이 없었다. 신뢰있는 BMD 산출을 위해서는 정기적으로 장비 및 검사자의 기능테스트와 이에 대한 적절한 교정행위가 이루어져야 할 것이다.

  • PDF