• Title/Summary/Keyword: P-P bonding

Search Result 891, Processing Time 0.029 seconds

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.

Dislocations as native nanostructures - electronic properties

  • Reiche, Manfred;Kittler, Martin;Uebensee, Hartmut;Pippel, Eckhard;Hopfe, Sigrid
    • Advances in nano research
    • /
    • v.2 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • Dislocations are basic crystal defects and represent one-dimensional native nanostructures embedded in a perfect crystalline matrix. Their structure is predefined by crystal symmetry. Two-dimensional, self-organized arrays of such nanostructures are realized reproducibly using specific preparation conditions (semiconductor wafer direct bonding). This technique allows separating dislocations up to a few hundred nanometers which enables electrical measurements of only a few, or, in the ideal case, of an individual dislocation. Electrical properties of dislocations in silicon were measured using MOSFETs as test structures. It is shown that an increase of the drain current results for nMOSFETs which is caused by a high concentration of electrons on dislocations in p-type material. The number of electrons on a dislocation is estimated from device simulations. This leads to the conclusion that metallic-like conduction exists along dislocations in this material caused by a one-dimensional carrier confinement. On the other hand, measurements of pMOSFETs prepared in n-type silicon proved the dominant transport of holes along dislocations. The experimentally measured increase of the drain current, however, is here not only caused by an higher hole concentration on these defects but also by an increasing hole mobility along dislocations. All the data proved for the first time the ambipolar behavior of dislocations in silicon. Dislocations in p-type Si form efficient one-dimensional channels for electrons, while dislocations in n-type material cause one-dimensional channels for holes.

TOXIC EFFECT OF ADHESIVE RESINS ON THE DOG'S PULP TISSUE (접착성(接着性) 레진이 가견치수조직(家犬齒髓組織)에 미치는 독성(毒性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.31-42
    • /
    • 1984
  • The toxic effect of adhesive resins on the dog's pulp tissue was studied with 70 teeth from 5 dogs. The experimental materials were Clearfil, a mixture of Clearfil with calcium hydroxide powder, Panavia-EX, and a mixture of Panavia-EX with calcium hydroxide powder. As a control group, calcium hydroxide powder was used. Each material was placed on the pulpotomized tissue surface. After 3 days, 1, 2,4, and 6 weeks, the teeth and apical tissue were processed routinly and stained with hematoxylin and eosin. Pathological tissue changes due to the toxicity of adhesive resins were observed by light microscope, and the pH of Panavia-EX and the Bonding agent of Clearfil were measured. Following were the results; 1. In the group of calcium hydroxide powder, slight inflammatory change was observed in the pulpotomized surface and adjacent pulp tissue on 3 day. 1 week case showed incomplete dentin bridge. The remaining pulp tissue was normalized according to the days elapsed. 2. In the group of Clearfil, early inflammatory change revealed in the superificial portion of the remaining pulp tissue on 3 day. The inflammation spreaded over the total pulp tissue and partial necrosis was observed in 1 week and 2 week cases. Total necrosis of pulp tissue and moderate inflammatory change at the apical tissue was noticed in 4 week and 6 week cases. 3. In the group of Panavia-EX, moderate inflammatory change appeared in the superficial pulp tissue on 3 day, and severe inflammatory change over all pulp tissue found in 1 week case. Pulp necrosis was obvious in 2 week case. 4 week and 6 week cases were totally necrotized up to the periapical tissue. 4. In the groups of mixtures with calcium hydroxide powder, the pulp tissue destruction was retarded, compared with the groups of Clearfil and Panavia-EX. 5. Panavia-EX was more destructive than Clearfil. 6. The acidity of freshly mixed Bonding agent of Cleafil was pH 4.0, and that of Panavia-EX was pH 2.0.

  • PDF

A Comparative Evaluation of Mechanical Properties of Orthodontic Wire Joints according to Soldering Methods (납착 방법에 따른 교정용 와이어의 기계적 특성 비교)

  • Lee, Hye-Jin;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the tensile strength and mechanical properties of orthodontic wire joints made by gas soldering and laser welding, with and without filling material, to identify the effectiveness and potential clinical application of laser welded orthodontic wires. Methods: Three joint configurations of orthodontic wire were used: diameter 0.9 to 0.9 mm wire, diameter 0.9 to 0.5 wire and diameter 0.9 mm wire to band. The joints were made using three different methods: gas soldering, laser welding with and without filling material. For each kind of joint configuration or connecting method 7 specimens were carefully produced. The tensile strengths were measured with a universal testing machine (Zwick/Roell, Instron, USA). The hardness measurements were carried out with a hardness tester(Future-Tech Co. Tokyo, Japan). Data were analyzed by AVOVA(p= .05) and Turkey HD test(p= .05). Results: In all cases, gas soldering joints were ruptured on a low level on tensile bonding strength. Significant differences between laser welding and gas soldering(p< .05) were found in each joint configuration. The highest tensile strength means were observed for laser welding, with filling material, of 0.9 to 0.9 mm wire joint. Conclusion: In conclusion, the elastic modulus and tensile strength means of laser soldering with filling material were the highest, and the tensile strength means of laser soldering were higher than those of gas soldering.

Evaluation of surface treatment methods on the bond strength of veneer ceramic to the zirconia core (지르코니아 코어와 전장용 세라믹의 결합 강도에 대한 표면 처리 방법 평가)

  • Lee, Gwang-Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.213-219
    • /
    • 2020
  • Purpose: This study aimed to identify the impact of physical surface roughing with a polishing tool onto the pre-sintering yttria-stabilized tetragonal zirconia polycrystals (TZP) core and liner treatment for chemical bonding on the bond strength of TZP core and veneering ceramic. Methods: Overall, 80 specimens were classified into two groups (non-liner, NL; and usingliner, UL ) depending on the use of liner, and these two groups were then subclassified into four groups depending on the polishing tool used. (1) Non-liner groups: NS, non-liner+stone point; NC, non-liner+carbide bur; NP, non-liner+paper cone point; NT, non-liner+silicon point. (2) Using-liner groups: US, using-liner+stone point; UC, using-liner+carbide bur; UP, usingliner+paper cone point; UT, using-liner+silicon point. The pre-sintering surface roughing values and shapes were observed, and after burning up the veneering ceramic, the shear bond strength was measured using a universal testing machine. For significance testing, a one-way analysis of variance and Tukey's multiple comparison test were conducted. An optical microscope was used to observe the fracture plane, and the following results were obtained. Results: Surface roughness NP (4.09±0.51 ㎛) represented a higher value than other groups (p<0.001). In shear bond strength, NS (35.21±1.44 MPa) of the NL group showed the highest bond strength (p<0.001). The UL group did not show a statistically significant difference between groups (p=0.612). Conclusion: Our study findings reveal that the bond strength of TZP core and veneering ceramic was improved by pre-sintering physical surface treatment than by chemical bonding with liner surface treatment.

THE MICROLEAKAGE OF LIGHT-CURED GLASS LONOMER RESTORATIVE MATERIALS IN CLASS V CAVITIES (제 5급와동에서 광중합 그래스 아이오노머 수복물의 미세변연누출에 관한 연구)

  • Cho, In-Sik;Park, Joon-Il;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.304-315
    • /
    • 1998
  • The purpose of this study was to evaluate the microleakage of light cured glass ionomer restorative materials in class 5 cavities. In this in vitro study, class 5 cavities were prepared on buccal and lingual surfaces of forty extracted human premolars and molars on cementum margin. These specimen were randomly divided into four groups of 10 each : Group 1 was Fugi II (control), Group 2 was Fugi II LC, Group 3 was Vitremer, and Group 4 was Dyract. Group 2 was also divided once more into 2 groups of 5 each : Group 2-1 was pretreated with dentin conditioner and Group 2-2 was not. All teeth were restored according to the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 40 teeth were placed in 2 % Methylene blue dye for 24hr, then rinsed with tab water. The specimen were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen were then observed with a stereomicroscope at 20. The results of the study were statistically analyzed using the Student-Newman-Keuls Methods and the Mann-Whitney Rank Sum Test. Tooth restorative interfaces were evaluated using SEM analysis. Results were as follows, 1. Compared to conventional glass ionomer restoratioqs, all light cured glass ionomer restorations were fairly resistant to microleakage (P<0.05). 2. Groups 3 (Vitremer) and Group 4 (Dyract) were found to be the most resistant, Group 2 (Fugi II LC) fairly resistant, and Group 1 (Fugi II) least resistant to microleakage(P<0.05). 3. No significant differences were found between Group 2-1 and Group 2-2 (P>0.08). 4. With the backscattered SEM analysis, the degrees to which tight bonding occurred were also observed in all the groups except for Group 1. Group 4 showed the highest degree of tight bonding than any other materials used in this study.

  • PDF

Coronal tooth discoloration induced by regenerative endodontic treatment using different scaffolds and intracanal coronal barriers: a 6-month ex vivo study

  • Shokouhinejad, Noushin;Razmi, Hassan;Farbod, Maryam;Alikhasi, Marzieh;Camilleri, Josette
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.25.1-25.10
    • /
    • 2019
  • Objective: The aim of this study was to evaluate discoloration of teeth undergoing regenerative endodontic procedures (REPs) using blood clot or platelet-rich fibrin (PRF) as the scaffolds and different calcium silicate-based materials as the intracanal coronal barriers in an ex vivo model. Materials and Methods: Forty-eight bovine incisors were prepared and disinfected using 1 mg/mL double antibiotic paste (DAP). The specimens were then randomly divided into 2 groups (n = 24) according to the scaffolds (blood or PRF). After placement of scaffolds each group was divided into 2 subgroups (n = 12) according to the intracanal coronal barriers (ProRoot MTA or Biodentine). The pulp chamber walls were sealed with dentin bonding agent before placement of DAP and before placement of scaffolds. The color changes (${\Delta}E$) were measured at different steps. The data were analyzed using 2-way analysis of variance. Results: Coronal discoloration induced by DAP was not clinically perceptible (${\Delta}E{\leq}3.3$). Regarding the type of the scaffold, coronal discoloration was significantly higher in blood groups compared with PRF groups at the end of REP and after 1 month (p < 0.05). However, no significant difference was found between PRF and blood clot after 6 months (p > 0.05). Considering the type of intracanal coronal barrier, no significant difference existed between ProRoot MTA and Biodentine (p > 0.05). Conclusions: With sealing the dentinal tubules of pulp chamber with a dentin bonding agent and application of DAP as an intracanal medicament, coronal color change of the teeth following the use of PRF and blood sealed with either ProRoot MTA or Biodentine was not different at 6-month follow-up.

Silver Colloidal Effects on Excited-State Structure and Intramolecular Charge Transfer of p-N,N-dimethylaminobenzoic Acid Aqueous Cyclodextrin Solutions

  • Choe, Jeong Gwan;Kim, Yang Hui;Yun, Min Jung;Lee, Seung Jun;Kim, Gwan;Jeong, Sae Chae
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.219-227
    • /
    • 2001
  • The silver colloidal effects on the excited-state structure and intramolecular charge transfer (ICT) of p-N,N-dimethylaminobenzoic acid (DMABA) in aqueous cyclodextrin (CD) solutions have been investigated by UV-VIS absorption, steady-state and time-resolved fluorescence, and transient Raman spectroscopy. As the concentration of silver colloids increases, the ratio of the ICT emission to the normal emission (Ia /Ib) of DMABA in the aqueous $\alpha-CD$ solutions are greatly decreased while the Ia /Ib values in the aqueous B-CD solutions are significantly enhanced. It is also noteworthy that the ICT emission maxima are red-shifted by 15-40 nm upon addition of silver colloids, implying that DMABA encapsulated in $\alpha-CD$ or B-CD cavity is exposed to more polar environment. The transient resonance Raman spectra of DMABA in silver colloidal solutions demonstrate that DMABA in the excited-state is desorbed from silver colloidal surfaces as demonstrated by the disappearance of νs (CO2-)(1380 cm-1 ) with appearance of ν(C-OH)(1280 cm -1) band, respectively. Thus, in the aqueous B-CD solutions the carboxylic acid group of DMABA in the excited-state can be readily hydrogen-bonded with the secondary hydroxyl group of B-CD while in aqueous and $\alpha-CD$ solutions the carboxylic acid group of DMABA has the hydrogen-bonding interaction with water. Consequently, in the aqueous B-CD solutions the enhancement of the Ia /Ia value arises from the intermolecular hydrogen-bonding interaction between DMABA and the secondary hydroxyl group of B-CD as well as the lower polarity of the rim of the B-CD cavity compared to bulk water. This is also supported by the increase of the association constant for DMABA/ B-CD complex in the presence of silver colloids.

Evaluation of Shear Bond Strength and Microleakage of Self-adhesive Giomer

  • Gwangsuk Kim;Juhyun Lee;Haeni Kim;Howon Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.4
    • /
    • pp.434-442
    • /
    • 2023
  • This study was aimed to evaluate the bonding performance of a self-adhesive giomer and compare it to a conventional flowable composite resin with regard to shear bond strength and microleakage in enamel and dentin. Healthy human premolars extracted for orthodontic treatments were used in the study. For shear bond strength tests, enamel and dentin specimens were prepared for the study group with self-adhesive giomer and for the control group with conventional flowable composite resin with a 5th-generation adhesive system. A universal testing machine was used to measure the shear bond strength. For the microleakage tests, specimens were immersed in a 2% methylene blue solution for 24 hours, cut into sections, and evaluated with a stereomicroscope for the extent of dye penetration. The results of the study showed no statistically significant difference in shear bond strength between the self-adhesive giomer and the conventional flowable composite resin in enamel (p = 0.091). On the contrary, in dentin, the self-adhesive giomer showed significantly lower shear bond strength (p < 0.0001). The microleakage of the self-adhesive giomer was significantly higher than that of the conventional flowable composite resin (p = 0.002). Self-adhesive giomer is considered useful for restoring small cavities at the enamel level of pediatric patients by reducing chair time with the advantage of a simple bonding process. However, as the study was conducted in a laboratory setting, further research in a clinical environment is deemed necessary.

Effects of Molecular Weight of Poly(4-vinylpyridine) on the Order-Disorder Transition of Molecular Bottle-brush Composed of Poly(4-vinylpyridine) and 3-Pentadecylphenol (P4VP과 PDP로 이루어진 Molecular Bottle-brush의 Order-Disorder Transition에 미치는 P4VP 분자량의 영향에 관한 연구)

  • 최종렬;조항규;전현애;노시태
    • Polymer(Korea)
    • /
    • v.24 no.4
    • /
    • pp.488-498
    • /
    • 2000
  • Molecular bottle-brush was prepared by hydrogen-bonding between poly(4-vinylpyridine)(P4VP) as main chain and 3-pentadecylphenol (PDP) as amphiphilic side chain. Variation of long period ( $L_{p}$), order-disorder transition temperature ( $T_{ODT}$) and mesomorphic structure of bottle-brush were investigated by changing various mole ratio (x) of pyridine group in P4VP and PDP and molecular weight of P4VP. Upper critical solution temperature (UCST) behaviour was observed. For x 0.8-0.9, maximum critical temperature was found. As molecular weight of P4VP was increased, phase transition occurred at higher temperature. It was found that phase behaviour of the bottle-brush was affected by mobility of P4VP as well as size and regularity of lamellar structure. The $L_{p}$ determined from analysis of crystal structure was in the range of 35 $\AA$ and 40 $\AA$ and was more affected by the molecular weight of P4VP than by mole ratio (x). However, if the molecular weight of P4VP was high, LP value was little affected.ted.d.

  • PDF