• 제목/요약/키워드: P-P bonding

검색결과 887건 처리시간 0.028초

인산염계 수용성 유리의 용출 및 구조 분석 (Dissolution and Structure Analysis of Phosphate Water Soluble glasses)

  • 윤영진;윤태민;이용수;강원호
    • 한국재료학회지
    • /
    • 제12권7호
    • /
    • pp.545-549
    • /
    • 2002
  • Potassium-Calcium-Phosphate glasses in range $XCaO\cdot(50-X)K_2O$ \cdot $50P_2$$O^{5}$were investigated. Glass transition temperature(Tg) of prepared glasses were below $520^{\circ}C$, thermal expansion coefficient from $270.3$\times$10^{7}$ to $604.5$\times$10^{7}$/$^{\circ}C$. The structure of XCaO.(50-X)$K_2$O\cdot$50P_2$$O^{5}$ glasses were examined by FT-IR spectroscopy indirectly. As CaO was increased, Ts, Tg, P-O-P bonding strength and chemical durability were increased. Glass surface change was observed with increasing dissolution time using bulk specimen, weight loss and pH change were measured as function of the dissolution time.

Acidities of Benzyltetrahydrothiophenium Halides in Water. A Simple Method of Estimation

  • 조봉래;김용관;한만소;오광진
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권12호
    • /
    • pp.1218-1222
    • /
    • 1995
  • The pKa values of benzyltetrahydrothiophenium halides 1a-f in water have been estimated by measuring the absorbances of the solution in aqueous hydroxide ion solution. Assuming that the ratios of the activity coefficients remains close to unity, the absorbance of the solution can be expressed as A/[SH]o=(εSH+εS-K[OH-])/(1+K[OH-]), where A, [SH]o, K, εSH, and εS- are the absorbance of solution, the initial concentration of 1a-f, the equilibrium constant, and the extinction coefficients for SH and S-, respectively. The εS- and K values that best fit with this equation were calculated by a nonlinear regression analysis with a large number of absorbance data determined at different [OH-] and [SH]o. The pKa values of the SH were then calculated with the relationship Ka=-log K+14. The validity of this method has been demonstrated by the excellent agreements between the experimental and literature pKa values of three organic acids. The pKa values of 1a-f estimated by this method are in the range of 12.5-15.3 and correlate well with the Hammett equation. The large negative deviation for the pKa values of 1e and 1f from the Hammett plot has been attributed to the extra hydrogen bonding between the phenyl group and water molecules attracted by the hydrophilic substituents.

Factors Influencing Physical Activity in Adolescents with Complex Congenital Heart Disease

  • Kwon, Su Jin;Choi, Eun Kyoung;Lee, Kyung Hee;Im, Yu-Mi
    • Child Health Nursing Research
    • /
    • 제25권3호
    • /
    • pp.262-272
    • /
    • 2019
  • Purpose: We aimed to identify factors influencing physical activity in adolescents with complex congenital heart disease. Methods: We recruited 92 adolescents with complex congenital heart disease from a tertiary medical center in Seoul, measured their levels of physical activity, and identified factors that influenced their physical activity levels using the Global Physical Activity Questionnaire, the New York Heart Association classification, congenital heart disease complexity, the Self-Efficacy Scale, and the Parental Bonding Instrument scale. Stepwise multiple linear regression was used to determine factors influencing physical activity. Results: Total physical activity was higher in males than in females (t=4.46, p<.001). Adolescents who participated in school physical education classes engaged in more physical activity than those who did not (t=6.77, p<.001). Higher self-efficacy (${\beta}=.41$, p<.001), male gender (${\beta}=.37$, p<.001) and participation in school physical education classes (${\beta}=.19$, p=.042) were associated with a higher likelihood of engagement in physical activity. Conclusion: It is necessary to develop nursing interventions that enhance self-efficacy in order to promote physical activity in adolescents with complex congenital heart disease. Physical activity should also be promoted in an individualized manner, taking into account gender, disease severity, and parental attitude.

컴포머 충전과정에 따른 상아질 투과도의 변화 (DENTIN PERMEABILITY CHANCE ACCORDING TO THE PROCESS OF COMPOMER RESTORATION)

  • 조혜진;이경하;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.382-388
    • /
    • 2002
  • Compomer is composed of matrix and filler : matrix is made of the combination of resins and polycarboxylic molecules that are light-cured, and a filler is a glass component which is capable of ion-release. The resin content of compomers produces polymerization shrinkage which can adversely affect marginal adaptation. Pretreatment is a fundamental step which is treated with conditioner or primer in the use of these materials. Microleakage of restorative materials has been investigated mostly by dye penetration method. Dye penetration method was not quantitative and not measured repeatedly. Fluid filtration method, introduced and developed by Pashley's group, has been extensively used for 20 years for research purpose to understand the physiology of dentin, as well as the effects of various restorative treatments on dentin permeability. It permits quantitative, nondestructive measurment of microleakage in a longitudinal manner. The purpose of this study was to evaluate the change of dentin permeability according to the process of compomer restoration. In this study. Cl V cavities were prepared on buccal surface of thirty extracted human molars. The prepared cavities were etched by 37% phosphoric acid. The experimental teeth were randomly divided into three groups. Each group was treated with following materials Group 1 : Prime & Bond NT/Dyract AP, Group2: Single Bond/F2000 compomer, Group 3 : Syntac Single Component/Compoglass. The bonding agent and compomer were applied for each group following manufacturers information. Dentin permeability of each group was measured at each process by fluid filtration method; Step 1 : preparation(smear layer). Step 2 : etching(smear layer removal), Step 3 : applying the bonding agent, Step 4 : filling the compomer. Dentin permeability was expressed by hydraulic conductance ($\mu\textrm{l}$ min$^{-1}$cm$H_2O$$^{-1}$). The data were analysed statistically using One-way ANOVA and Sheffe's method. The results were as follows : 1. Dentin permeability differences between each process were significant except between step 1 and step 2(p<0.01). 2. Dentin permeability after removal of smear layer was highly increased(p<0.01). 3. In most case, decrease of dentin permeability was obtained by applying bonding agent(p<0.01). 4. Dentin permeability differences among the experimental groups were not significant(p>0.05). 5. None of compomers used in this study showed perfect seal at the interface.

브라켓 부착 시 실런트 레진이 법랑질 탈회에 미치는 영향 (The effects of a sealant resin on enamel demineralization in orthodontic bracket bonding)

  • 윤영아;조진형;이기헌
    • 대한치과교정학회지
    • /
    • 제35권1호
    • /
    • pp.43-50
    • /
    • 2005
  • 본 연구는 교정용 브라켓 부착 시 사용되는 접착제 중 two paste type의 실런트 레진 적용이 법랑질 탈회에 미치는 영향을 알아보고자 시행되었다. 건전한 표면을 가진 발치된 소의 상악절치 48개를 실험재료로 하여 법랑질 처리 방법에 따라 4개 군으로 분류하고 각 군을 Phase II (Reliance, Itasca III)를 이용하여 치면처리 하였다. 대조군으로서 아무런 처리를 하지 않은 Group 1.37% 인산으로 30초간 산부식을 시행한 Group 2, 산부식 후 실런트 A와 B를 동량으로 혼합하여 도포한 Group 3과 산부식 후 실런트를 도포하고 레진 페이스트 A와 B를 동량으로 혼합하여 도포한 Group 4로 분류하여 각 군을 인공탈회용액에서 탈회시킨 다음 공초점 레이저 주사현미경을 이용하여 각각의 탈회된 깊이를 측정한 후 비교한 결과, 탈회된 법랑질의 평균 깊이는 $47.4{\mu}m$ (Group 1). $61.8{\mu}m$ (Group 2). $13.9{\mu}M$(Group 3) $8.2{\mu}n$ (Group 4) 로 나타났다. 산부식 후 인공탈회용액에 노출되는 군 (Group 2) 은 산부식 없이 노출도는 군 (Group 1) 센 비해 탈회된 깊이가 더 깊은 것으로 나타났으며 (p<0.05) 실런트 레진을 도포한 군 (Group 3: 은 산부식 없이 노출되는 군 (Group 1)이나 산부식 후 노출되는 군 (Group 2) 에 비해 탈회된 법랑질 깊이가 유의성 있게 감소하였다. (p<0.05). 접착레진으로 부착된 군 (Group 4)은 법랑질 탈회가 거의 나타나지 않았다. 이상의 연구결과는 교정치료 시 법랑질 탈회 가능성을 줄이기 위해서 브라켓 부착 시 실런트 레진의 도포가 유용함을 시사하였다.

복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구 (THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS)

  • 전철민;권혁춘;이정식;이명종;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA : PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA : QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도(Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mW/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490 nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.00).

  • PDF

타액 오염하에서 수복방법에 따른 컴포머의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE ACCORDING TO RESTORATION METHOD OF COMPOMER UNDER SALIVA CONTAMINATION)

  • 공석배;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.73-80
    • /
    • 2007
  • 소아 환자의 인접면 우식을 치료할 때 컴포머는 불소를 방출하는 재료로 유용하게 사용될 수 있다. 하지만 구강내 환경은 항상 습윤한 상태로 타액은 컴포머와 치질 사이의 접착을 방해할 수 있다. 수복시에 타액이 게재하게 되면 미세누출이 발생할 가능성이 높아지게 되며 그로 인해서 수복의 실패가 일어날 수 있다. 이에 본 연구에서는 컴포머를 수복할 시에 타액의 영향과 수복 방법에 따른 미세누출 정도를 평가하기 위해서 시행하였다. 컴포머로서 Dyract $AP^{(R)}$(Dentsply, Germany)를 사용하였으며 Dentin bonding agent로는 Prime and $Bond^{(R)}$ NT (Dentsply, Germany)를 사용하였고, 광중합을 위해서 Elipar Trilight (3M ESPE, USA)를 사용하였다. 구강내 환경을 재현하기 위해서 saliva pool을 제작하였다. 소구치 2개를 인접하여 시편을 제작한 후에 2급 와동을 형성하여 수복 환경을 다르게 하여 컴포머를 충전한 후에 500회 thermocycling하였다. 그 후 0.5% methylene blue 용액에 24 시간 동안 담근 후에 실체 현미경을 통해서 교합면과 치은면에서의 미세누출 정도를 측정하였다. Kruskal-Wallis Test와 Mann-Whitney Test를 이용하여 각 군간 유의성을 검정하여 다음과 같은 결과를 얻었다. 1. 교합면에서의 각 군간 통계학적 차이는 없었다(p>0.05). 2. 치은면에서 $Oraseal^{(R)}$을 이용하여 수복한 3군이 타액 오염을 시키지 않은 4군과 통계학적 차이가 없었다(p>0.05). 3. 치은면에서 1군과 2군 사이에는 통계학적 차이가 없었다(p>0.05). 4. 치은면에서 $Oraseal^{(R)}$을 이용하여 수복한 3군이 1, 2군보다 통계학적으로 더 낮은 미세누출 정도를 보였다(p<0.05).

  • PDF

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA; PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA; QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도 (Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mw/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.001).

수열합성법을 이용한 NiCrAl 합금 폼 위에 합성된 NiO 촉매 형상 제어 (Morphology Control of NiO Catalysts on NiCrAl Alloy Foam Using a Hydrothermal Method)

  • 신동요;이은환;박만호;안효진
    • 한국재료학회지
    • /
    • 제26권7호
    • /
    • pp.393-399
    • /
    • 2016
  • Flower-like nickel oxide (NiO) catalysts were coated on NiCrAl alloy foam using a hydrothermal method. The structural, morphological, and chemical bonding properties of the NiO catalysts coated on the NiCrAl alloy foam were investigated by field-emission scanning electron microscopy, scanning electron microscopy-energy dispersive spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, respectively. To obtain flower-like morphology of NiO catalysts on the NiCrAl alloy foam, we prepared three different levels of pH of the hydrothermal solution: pH-7.0, pH-10.0, and pH-11.5. The NiO morphology of the pH-7.0 and pH-10.0 samples exhibited a large size plate owing to the slow reaction of the hydroxide ($OH^-$) and nickel ions ($Ni^+$) in lower pH than pH-11.5. Flower-like NiO catalysts (${\sim}4.7{\mu}m-6.6{\mu}m$) were formed owing to the fast reaction of $OH^-$ and $Ni^{2+}$ by increased $OH^-$ concentration at high pH. Thus, the flower-like morphology of NiO catalysts on NiCrAl alloy foam depends strongly on the pH of the hydrothermal solution.