• Title/Summary/Keyword: P-Grid

Search Result 383, Processing Time 0.023 seconds

MULTIDIMENSIONAL INTERPOLATIONS FOR THE HIGH ORDER SCHEMES IN ADAPTIVE GRIDS (적응 격자 고차 해상도 해법을 위한 다차원 내삽법)

  • Chang, S.M.;Morris, P.J.
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.39-47
    • /
    • 2006
  • In this paper, the authors developed a multidimensional interpolation method inside a finite volume cell in the computation of high-order accurate numerical flux such as the fifth order WEND (weighted essentially non-oscillatory) scheme. This numerical method starts from a simple Taylor series expansion in a proper spatial order of accuracy, and the WEND filter is used for the reconstruction of sharp nonlinear waves like shocks in the compressible flow. Two kinds of interpolations are developed: one is for the cell-averaged values of conservative variables divided in one mother cell (Type 1), and the other is for the vertex values in the individual cells (Type 2). The result of the present study can be directly used to the cell refinement as well as the convective flux between finer and coarser cells in the Cartesian adaptive grid system (Type 1) and to the post-processing as well as the viscous flux in the Navier-Stokes equations on any types of structured and unstructured grids (Type 2).

DEVELOPMENT OF A HIGH-ORDER NUMERICAL METHOD IN THE QUADRILATERAL ADAPTIVE GRIDS (사각형 적응 격자 고차 해상도 수치 기법의 개발)

  • Chang, S.M.;Morris, P.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.47-50
    • /
    • 2006
  • In the aeroacoustic application of computational fluid dynamics, the physical phenomena like the crackle in the unsteady compressible jets should be based on very time-accurate numerical solution. The accuracy of the present numerical scheme is extended to the fifth order, using the WENO filter to the sixth-order central difference computation. However, the computational capacity is very restricted by the environment of computational power, so therefore the quadrilateral adaptive grids technique is introduced for this high-order accuracy scheme. The first problem is the multi-dimensional interpolation between fine and coarse grids. Some general benchmark problems are solved to show the effectiveness of this method.

  • PDF

Experimental and Computational Investigation of the Flow around a Circular Cylinder (실험 및 중첩격자를 이용한 수치해석에 의한 원형단면체 주위의 유동고찰)

  • ;Yim, Geun-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.130-140
    • /
    • 1997
  • 원형주상체 주위의 유동을 규명하기 위해 회류수조에서 원주방향으로 24개의 위치에 대하여 압력을 계측하였으며, laser sheet을 이용하여 유동을 가시화 하였다. Reynolds수가 4800에서 40000인 범위에 대하여 실험을 수행하였다. 또한, 원형단면체 주위의 비정상 층류유동에 대한 Navier-Stokes방정식의 해를 구하는 수치해석기법을 개발하였다. 효과적인 격자배치를 위하여 H와 O-type의 중첩격자를 사용하였고, 이산화 방법으로는 정규격자시스템에서 유한차분법을 적용하였다. 실험과 수치해석결과에서 뚜렷한 와류박리현상을 볼 수 있었으며, 압력계수 (C$_{p}$ ), 항력계수(C$_{D}$), 스트로얼수(St)를 정량적으로 비교하였을 때, 비교적 잘 일치하는 것을 확인하였다.다.

  • PDF

Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR) (DVR의 특성을 고려한 매칭변압기의 자속포화 해석)

  • Shon, Jin-Geun;Kim, Dong-Joon;Kang, Min-Gu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

Development of Black Box for EV Charging Infra based on Solar Power Generation and ESS (태양광발전 및 ESS 기반 전기차 충전인프라용 블랙박스 개발)

  • Kim, Dong-Wan;Park, Ji-Ho;An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.160-167
    • /
    • 2018
  • In this paper, a black box, which is provided the reliability and user safety of home battery energy storage system connected with solar energy generation, is developed. In the developed scheme, a status and diagnosis data of battery management system, power conditioning system, solar energy generation and grid is measured. This status and diagnosis data is stored and displayed in the developed black box. In addition, this status and diagnosis data is stored and displayed in a monitoring system and a smart phone of user. A performance evaluation of the developed black box is carried out using emulator of home battery energy storage system connected with solar energy generation. Consequently, the developed black box is proved its superiority of the reliability and user safety.

Development of the 4kW Photovoltaic Power Conditioning System (4kW 태양광 발전용 PCS 개발)

  • Lee, H.D.;Park, Y.H.;Jeon, S.B.;Kim, J.G.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.291-292
    • /
    • 2010
  • The main purpose of this study is to design and develop the grid connected 4kW photovoltatic PCS(Power Conditioning System) targeting for Japanese market. To make this task, the development of DC to DC converter, one phase inverter and EMI filters, and the research on connection between inverter and utility line are made. The developed 4kW PCS has fully carried out performance verifications and evaluation works and acquired the JET(Japan Electrical Safety & Environment Technology Laboratories) certification for safety and performance.

  • PDF

The effect of the injection molding conditions on the shrinkage of HIPS (사출성형조건이 HIPS 수축율에 미치는 영향)

  • Cha B. S.;Rhee B. O.;Choi K. I.;Koo B. H.;Park H. P.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.259-264
    • /
    • 2005
  • The shrinkage of the product in injection molded part occurs due to the volume change with variation of temperature and pressure and is influenced by the processing conditions of injection molding. Mold designers greatly concerns the shrinkage of parts for a high dimensional accuracy. In this study, bar type HIPS specimen with 15x19 grid on the surface was tested. The amount of shrinkage of flow and transverse directions was examined with respect to the injection molding conditions such as melt temperature, injection speed, holding pressure, mold temperature and cooling time. As the packing pressure increased, the difference of shrinkage of both directions is decreased and the absolute shrinkage value also decreased.

  • PDF

An Optimal Thresholding Technique for Anti-scatter Grid Artifact Detection (비산란 그리드 결함 검출을 위한 최적 임계치결정 기법)

  • Park, Daul;Chung, Woohyun;Kang, Yoonseok;Jung, Joongeun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.954-956
    • /
    • 2017
  • 본 연구에서는 X-선 영상을 이용한 비산란 그리드의 검사 자동화 시스템에서, 결함후보 ROI에 대한 판단정확도를 향상시킬 수 있는 최적영상 획득을 위한 임계치결정 기법을 제안한다. 주파수 도메인에서 영상히스토그램을 분석 및 재구성한 후 최적임계치의 결정에 필요한 요소를 추출하며, 재구성 히스토그램으로부터 영상패턴을 판단하여 각 유형에 따른 최적 임계치를 결정한다. 50개의 영상에 적용한 실험 결과 제안된 방법은 4.8/5.0의 성능 (Inter-class correlation, ICC: 0.985, 95% CI, p-value<0.05)을 보였다.

A Study on Combination Technology of a Transformer and a Superconducting Fault Current Limiter (변압기와 초전도한류기의 결합기술 연구)

  • Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.330-334
    • /
    • 2010
  • We tried to combine a transformer with a superconducting element and investigated the current limiting characteristics. When a superconducting element was connected to third winding of the transformer, the fault current was limited to about 90 % effectively. The fault current and consumption power were able to be controlled by the turn's ratio of secondary and third windings. It gives flexibility of the rating of a transformer in the power grid. As a result, power burden of a superconducting element was reduced by the decrease of turn's ratio in third winding of a transformer. It was because the voltage behavior of a superconducting element was dependent on turn's ratio of a transformer while the current characteristic was independent.

Application of Threat Modeling for Security Risk Analysis in Smart Home Service Environment (스마트홈 서비스 환경에서의 보안 위험 분석을 위한 위협 모델링 적용 방안)

  • Lee, Yun-Hwan;Park, Sang-Gun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.76-81
    • /
    • 2017
  • In this paper, the risk analysis of smart home services was implemented by applying threat modeling. Identified possible threats for safe deployment of smart home services and identified threats through the STRIDE model. Through the creation of the Attack Tree, the attackable risk was analyzed and the risk was measured by applying the DREAD model. The derived results can be used to protect assets and mitigate risk by preventing security vulnerabilities from compromising and identifying threats from adversely affecting services. In addition, the modeled result of the derived threat can be utilized as a basis for performing the security check of the smart home service.