• Title/Summary/Keyword: P loading

Search Result 1,471, Processing Time 0.024 seconds

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

Effect of Taping Therapy for Increasing the weight loading on Affected Leg of Hemiparesis (테이핑요법을 통한 중풍 편마비환자의 환측 하지체중부하율 변화에 대한 임상연구)

  • Han, Soon-Hyun;Kim, Sung-Soo;Ryu, Han-Jin
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.4 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • Objective: In order to study the effect of Taping Therapy for Increasing the weight loading on Affected Leg of Hemiparesis, a clinical study was performed. Method: Tapes were applied on gluteus medius and quadriceps femoris muscle. Weight loading on the Affected Leg of Hemiparesis was measured by two digital scales at before and after, after 30 minites, after 1 hour of treatment. From each score of two scales, we calculate the percentage of Weight loading on the Affected Leg of hemiparesis. Result: (1)Case 1: Only the percentage of Weight loading measured after treatment is effectively increased(from $47.38{\pm}0.99$ to $46.36{\pm}1.2$(p<0.05)) (2)Case 2: The percentage of Weight loading measured both after treatment and after 30 minute is effectively increased(the one is increased from $10.75{\pm}0.476$ to $12.04{\pm}1.717$ and the other is increased from $10.75{\pm}0.476$ to $15.09{\pm}2.454(p<0.05)$) (3)Case 3: The percentage of Weight loading measured at all times is effectively increased. (the one after treatment is increased from $31.59{\pm}0.606$ to $29.55{\pm}2.296$. the one after 30 minutes. is increased from $31.59{\pm}0.606$ to $45.40{\pm}0.86$, from the one after 1 hour is increased from $31.59{\pm}0.606$ to $52.70{\pm}0.541$(p<0.05)) Conclusion: (1)The percentage of Weight loading measured after treatment is effectively increased (2)The percentage of Weight loading measured after 30 minutes and 1 hour is effectively increased, so it means Taping Therapy is continueously effective. (3)The percentage of Weight loading is especialy increased when the Percentage of weight loading is near 30%

  • PDF

ASSESSMENT OF IMPLANT STABILITY AFTER IMMEDIATE LOADING IN DOGS : CLINICAL AND RADIOGRAPHIC STUDY (성견에서 즉시 부하 후 임프란트 안정성 평가 : 임상적, 방사선학적 연구)

  • Lee, Joo-Young;Kim, Su-Gwan;Kim, Sang-Ho;Kim, Wan-Bae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.131-139
    • /
    • 2005
  • The therapeutic goal of implant dentistry is not merely tooth replacement but total oral rehabilitation. Considering dental implants as a treatment option can be provided patients with positive, long-term results. Implant dentistry has gone through many phases over the years. Modern technology and design allows us to predictably place our dental implants often load the implants at the time of placement. The purpose of this study is to evaluate the implant stability after immediate loading in dogs. The control group was performed delay loading and experimental group was immediate loading. Each group was measured periotest value(PTV) to evaluate clinical mobility and performed radiographic examination to evaluate marginal bone loss. Statistically significant difference was not founded in control group between experimental group in PTV(P>0.05) and marginal bone loss(P>0.05). Finally, implant stability after immediate loading was similar to delay loading implant.

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING (임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향)

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).

Prediction of Nutrient Loading from Paddy Fields (II) - Model Application - (논에서의 영양물질 배출량 추정 (II) - 모형의 적용 -)

  • 김현수;정상옥;김진수;오승영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.106-115
    • /
    • 2002
  • The objective of this study was to evaluate the GLEAMS-PADDY model by applying it to estimate nutrients loading from paddy-field areas. Field data from Soro region of Chungbuk province during May to September 1999 were used for model application. Field data collected include the amounts of rainfall, irrigation water, drainage water, ET, and Percolation in hydrology Part. T-N and T-P concentrations in the rain water, irrigation water, ponded water, drainage water and percolated water were measured. The comparisons of observed and simulated water balance components and nutrient concentrations showed reasonably good agreements and the GLEAMS-PADDY model may be used to simulate nutrients loading from paddy fields. Futher research was suggested to include the erosion submodel in the GLEAMS-PADDY model to better simulate the nutrient behavior. In addition, the pesticide submodel also recommended to be included in order to simulate the various pesticide applied in paddy fields.

Runoff Loading of Nutrients from a Paddy Field during Non-Cropping Season (비영농기간 단일필지 논으로부터 영양물질의 유출량)

  • 조재영;한강완;최진규;구자웅;손재권
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.759-764
    • /
    • 1999
  • In intensive agriculture, exceeded chemical fertilizer application would increase the concentration of nitrate nitrogen in groundwater. Consequently, it could bring the eutrophication in lakes and streams. The present study examined runoff loading of nitrogen and phosphorus from the paddy field during non-cropping season. The runoff loading of total-N, ammonia-N, nitrate-N and total-P were 12.96kg/ha, 5.42kg/ha, 1.52kg/ha and 1.41kg/ha. When the runoff loading of nutrients was compared by runoff water and sediments. About 70-80% of total-N by runoff water and the rest 20-30% by runoff sediments were flowed into streams. But 60-70% of total-P by runoff sediments and the rest 30-40% by runoff water were flowed into streams. The phosphorus compounds, which were flowed into streams by runoff sediments and then sedimented, keep exchanging with water at water body in undelivered condition. And it moves gradually into water layer. This process can cause eutrophication continually and repeatedly in water environment. So, a sound program is needed to reduce soil erosion from farmlands.

  • PDF

Runoff Loading on Nutrients from a Paddy Field during Non-Cropping Season (비영농기간 단일필지 논으로부터 영양물질의 유출부하량)

  • 조재영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.2
    • /
    • pp.63-70
    • /
    • 2000
  • The present study was carried out for 7-months (from October 1.1997 to April 30. 1998) at a rice cultivation area blocked from livestock farming, farmstead and industrial complex to investigate the runoff loading of nitrogen and phosphorus in a plot(5,000$m^2$) paddy field areas. The runoff loading of total-N, amminia-N nitrate-N and total-P were 12.96kg/ha, 5.42kg/ha, 1.52kg/ha and 1.41kg/ha , respectively. When the runoff loading of nutrients was compared by dissolved and adsorbed forms, about 66% of total-N by dissolved form and the rest 34% by adsorbed form were flowed into streams. But 56% of total-P by adsorbed form and the rest 44% by dissolved form were flowed into streams. The phosphrous compounds , which were flowed into streams by runoff sediments and then sedimented, keep exchanging with water at water body in undelivered condition. And it moves gradually into water layer. This process can cause eutrophication continually and repeatedly in water environment . So, a sound program is needed to reduce soil erosion from farmlands.

  • PDF

Analysis of Dynamic Behavior of a Single Pile in Dry Sand by 1g Shaking Table Tests (1g 진동대 실험을 통한 건조사질토에 근입된 단독말뚝의 동적 거동 분석)

  • Lim, Hyun-Sung;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.7
    • /
    • pp.17-28
    • /
    • 2017
  • This paper presents the investigation of dynamic behavior of a single pile in dry sand based on 1g shaking table tests. The natural frequency of soil-pile system was measured, and then a range of loading frequency was determined based on the natural frequency. Additionally, the studies were performed by controlling loading accelerations, pile head mass and connectivity conditions between pile and cap. Based on the results obtained, relatively larger pile head displacement and bending moment occur when the loading frequency is larger than the natural frequency of soil-pile system. However, the slope of the p-y curve is smaller in the similar loading frequency. Also, it was found that inertia force like input acceleration and pile head mass, and relation of the natural frequency of soil-pile system and input frequency have a great influence on the slope of dynamic p-y curve, while pile head conditions don't.

CPT-based p-y analysis for mono-piles in sands under static and cyclic loading conditions

  • Kim, Garam;Kyung, Doohyun;Park, Donggyu;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.9 no.3
    • /
    • pp.313-328
    • /
    • 2015
  • In the present study, a CPT-based p-y analysis method was proposed for offshore mono-piles embedded in sands. Static and cyclic loading conditions were both taken into account for the proposed method. The continuous soil profiling capability of CPT was an important consideration for the proposed method, where detailed soil profile condition with depth can be readily incorporated into the analysis. The hyperbolic function was adopted to describe the non-linear p-y curves. For the proposed hyperbolic p-y relationship, the ultimate lateral soil resistance $p_u$ was given as a function of the cone resistance, which is directly introduced into the analysis as an input data. For cyclic loading condition, two different cyclic modification factors were considered and compared. Case examples were selected to check the validity of the proposed CPT-based method. Calculated lateral displacements and bending moments from the proposed method were in good agreement with measured results for lateral displacement and bending moment profiles. It was observed the accuracy of calculated results for the conventional approach was largely dependent on the selection of friction angle that is to be adopted into the analysis.