• Title/Summary/Keyword: P axis

Search Result 966, Processing Time 0.041 seconds

Analysis on the source characteristics of three earthquakes nearby the Gyeongju area of the South Korea in 1999 (1999년 경주 인근에서 3차례 발생한 지진들의 지진원 특성 분석)

  • Choi, Ho-Seon;Shim, Taek-Mo
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.509-515
    • /
    • 2009
  • Three earthquakes with local magnitude ($M_L$) greater than 3.0 occurred on April 24, June 2 and September 12 in 1999 nearby the Gyeongju area. Redetermined epicenters were located within the radius of 1 km. We carried out waveform inversion analysis to estimate focal mechanism of June 2 event, and P and S wave polarity and their amplitude ratio analysis to estimate focal mechanisms of April 24 and September 12 events. June 2 and September 12 events had similar fault plane solutions each other. The fault plane solution of April 24 event included those of other 2 events, but its distribution range was relatively broad. Focal mechanisms of those events had a strike slip faulting with a small normal component. P-axes of those events were ENE-WSW which were similar to previous studies on the P-axis of the Korean Peninsula. Considering distances between epicenters, similarities of seismic waves and sameness of polarities of seismic data recorded at common seismic stations, these events might occurred at the same fault. The seismic moment of June 2 event was estimated to be $3.9\;{\times}\;10^{14}\;N{\cdot}m$ and this value corresponded to the moment magnitude ($M_W$) 3.7. The moment magnitude estimated by spectral analysis was 3.8, which was similar to that estimated by waveform inversion analysis. The average stress drop was estimated to be 7.5 MPa. Moment magnitudes of April 24 and September 12 events were estimated to be 3.2 and 3.4 by comparing the spectrum of those events recorded at common single seismic station.

Effect of Short Term Treatment with Different Dosage of Inhaled Flucatisone Propionate on Basal Cortisol Concentration (단기간 Fluticasone Propionate 투여 용량에 따른 가저 코르티솔 농도의 변화)

  • Kim, Hyun-Jung;Kim, Hyoung-Sik;Lee, Hong;Moon, Sung-Gi;Lim, Seok-Tae;Park, Ji-Hyun;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1063-1071
    • /
    • 1997
  • Backgroung : The efficacy of oral corticosteroids in the treatment of chronic asthma is undisputed, but their long-term use is associated with adverse side-effects, including supression of the hypothalamic-pituitary adrenal axis function, osteoporosis, weight gain, hypertension and impaired glucose tolerance. The introduction of inhaled corticosteroids in the early 1970's represented a significant therapeutic advance in the management of asthma, since these compounds combined high topical potency with low systemic activity. Fluticasone propionate is a new topically active synthetic glucocorticosteroid that combinds a high degree of efficacy with negligible systemic bioavailability. This study was perfomed to determine the effect of inhaled fluticasone propionate on the adreocortical supression in patients with bronchial asthma or chronic obstructive pulmonary disease. Method : The adrenocortical function was assessed by measurement of plasma cortisol concentration at 8 o'clock in morning and free cortisol in 24 hour urine collection at interval. Absolutely, no steroid was taken during pretreatment period of 10days. There after each subject inhaled fluticasone aerosol, in daily doses of 500 or 1000micrograms for 12days. The dose was delivered by metered dose inhaler(MDI). Results : The serum cortisol and 24hour urinary free cortisol were not decreased during the treatment period in patients with inhaled fluticasone propionate in daily doses of 500 micrograms. In contrast, serum cortisol was significantly decreased on 9th and 12th day(p less than 0.05). And, 24hour urinary free cortisol was also significantly decreased on 3rd and 12th day of treatement period(p less than 0.05) in patients with inhaled fluticasone in daily doses of 1000 micrograms. Conclusion : These results suggested that endogenous cortisol secretion was not supressed after short-term inhalation of fluticasone in daily dose of 500 micrograms, but in daily dose of 1000 micrograms, the endogenous cortisol secretion was supressed.

  • PDF

Toxicity Test of butachlor to Medaka (뷰타클로르의 송사리에 대한 독성시험)

  • Park, Yeon-Ki;Kim, Byung-Seok;Shin, Jin-Sup;Bae, Chul-Han;Park, Kyung-Hun;Lee, Jea-Bong;Hong, Soon-Sung;Cho, Kyung-Won;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.4
    • /
    • pp.254-260
    • /
    • 2007
  • In order to evaluate the toxic effects of butachlor, a herbicide widely used for control of weeds in paddy field, on medaka (Oryzias latipes), acute toxicity tests for five developmental stages and early life stage toxicity test of were conducted. As the results of acute toxicity test, $96h-LC_{50}s$ for 1 day, 1 week, 2 weeks, 2 months and 5 months after hatching of O. latipes were 0.68, 0.52, 0.38, 1.09 and $0.45\;mg\;L^{-1}$, respectively. This indicated that the most sensitive stage was 2 weeks after hatching. The early life stage toxicity test showed that no statistically significant hatching period and hatching success of embryo was observed at all concentrations of butaclor. However, 0.05 and $0.1\;mg\;L^{-1}$ of butachlor showed statistically significant post hatching survival with p<0.1. Abnormalities of larva were 2.1, 2.3 and 10% at 0.025, 0.05 and $0.1\;mg\;L^{-1}$ of concentration, respectively. They showed abnormal vertebral axis, craniofacial alteration and retarded yolk-sac resorption. The total length and weight were decreased depending on butachlor concentration the end of test. Weight of larva was showed more sensitive toxic indicator than total length. The toxicological responses of O. latipes to butachlor expressed as LOEC(lowest observed effect concentration), NOEC(no observed effect concentration) and MATC(maximum acceptable toxicant concentration) values were 0.025, 0.013 and $0.018\;mg\;L^{-1}$, respectively.

Growth promoting effect of short-term gonadotropin releasing hormone agonist with or without growth hormone in girls with early puberty (조기 사춘기 여아에서 단기간 성선자극호르몬 방출호르몬 효능약제와 성장호르몬 병합투여의 성장촉진 효과)

  • Lee, Eun-Ju;Han, Heon-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.2
    • /
    • pp.198-204
    • /
    • 2007
  • Purpose : The hope that arresting pubertal developement might increase final adult height has led to an attempt to use GnRH agonist (GnRHa) in children with early puberty and poor growth prognosis. We investigated the growth-promoting effect of GnRH agonists with or without growth hormone (GH) in girls with early puberty and decreased predicted adult height (PAH). Methods : Thirty five girls with advanced bone age and early pubertal signs were randomized for treatment for about 1 year with monthly GnRHa in group 1 (n=18), or with a combination of GH and GnRHa in group 2 (n=17). The following growth parameters were compared between groups, and the difference ($\Delta$) before and after treatment : chronological age (CA), bone age (BA), $\Delta$(BA-CA), height (HT), target height (TH), predicted adult height (PAH), $\Delta$ (TH-PAH), serum insulin-like growth factor (IGF-1) and insulin-like growth factor binding protein (IGFBP-3). Results : Before treatment, BA, TH, PAH Standard deviation scores (SDS), $\Delta$(TH-PAH) were not different between the two groups, but CA was higher in group 2 and $\Delta$(BA-CA) were higher in group 1 (P<0.05). After $1.06{\pm}0.93$ year of treatment, $\Delta$ (BA-CA) decreased and there were significant changes in PAH and $\Delta$ (TH-PAH), especially in group 2 (P<0.05 in group 1, and P<0.001 in group 2). In both groups, IGF-1 and IGFBP-3 were not different before and after treatment, but after treatment, IGF-1 level in group 2 was marginally higher than IGF-1 in group 1 (P<0.1). Conclusion : Compromised predicted adult height in girls with early puberty and advanced bone age was significantly improved with GnRH with/without GH treatment in the short-term period. The addition of GH to GnRHa results in a significant increase in PAH compared to GnRHa alone because GnRHa suppressed growth hormone-IGF-1 axis. For comparison of final adult height, further longitudinal follow-up will be needed.

Studies on- Electrocardiogram of the Normal Korean Native Goat 1. Standard Limb Leads and Unipolar Limb Leads (정상적인 한국 흑염소의 심전도에 관한 연구 1. 표전지유도와 단극지유도)

  • 최인혁;김선기;김추철;최인방;김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.319-337
    • /
    • 1997
  • The electrocardiographic (ECG) parameters in the normal Korean black goat have been measured with a 3-channel Electrocardiograph and computed, analyzed. ECG in 243 black goats were made with the limb leads (I, II, III, aVR, aVL, aVF), that were recorded conduction parameters of wave and interval, and were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate were recorded by the ECG which were a mean of 106.1$\pm $21.8 beats/min. Average conduction times in the PR, the QRS complex and the QTc interval were recorded 103.9$\pm $34.9 msec., 58.3$\pm $23.2 msec. and 302.6$\pm $67.8 msec., in the P and T wave duration recorded 24.8$\pm $6.4 msec. and 51.7$\pm $10.8 msec. respectively. The shape of wave in each leads were observed various types, and any spacial wave type appeared the highest frequency in each lead that ware shown less than 60%, and these frequent rate and average amplitudes as fallow: 1. In P waver the frequent rate and average amplitudes of the positive type showed in leads I, II and aVL that were 54.8% (93.0$\pm $ 33.2 $\mu $V), 50.5% (90.1$\pm $30.5 $\mu $V) and 41.7% (58.5$\pm $ 31.1 $\mu $V). Average amplitude of the negative type showed the frequent rate of 49.8% in lead aVE which was -77.6$\pm$ 25.2 $\mu $V. Biphasic type in leads III and aVF were 46.1% (108.4 $\mu $V, -90.2 $\mu $V.) and 45.7% (137.4 $\mu $V, -105.4 $\mu $V.), and amplitudes between positive and negative of it were significant difference. 2. The highest amplitudes of the QRS complex in all leads were 534.8$\pm $ 232.3 $\mu $V of lead II. The frequent rate and amplitudes of the R wave type in the I, II, III and aVF were 30.2% (277.8 $\pm $131.3 $\mu $V), 45.1% (393.1$\pm $114.2 $\mu $V), 48.5% (349.3$\pm $178.3 $\mu $V) and 54.9% (334.4$\pm $129.7 $\mu $V), and QS ways type in the lead aVL was 49.5% (359.2$\pm $195.5$\mu $V), and RS and QS wave types in the lead a VR were 43.3% (312.4 $\mu $V, -212.7 $\mu $V.) and 41.1% (399.2$\pm $92.2 $\mu $V), respectively. 3. In T wave, the frequent rata and amplitudes of the positive type in the leads I, II, III and aVF were 44.6% (207.9$\pm $ 97.1 $\mu $V), 41.6% (245.1$\pm $92.1 $\mu $V), 46.9% (189.8$\pm $ 82.7 $\mu $V) and 53.0% (195.4197.8 $\mu $V), and the negative in the lead aVR was 41.2% (-230.7$\pm$ 103.1 $\mu $V), respectively. The positive and negative types in the lead aVe appeared with same frequent rate of 43.2%.4. Frontal plane vectors for P, QRS, and T were found to lie at 38.1$\pm $ 21.5, 142.0$\pm $ 57.2, and 117.2$\pm $ 63.9 degrees, respectively. These results in ECG of goats may be served to the limited purposes as to conduction parameters, arrhythmias except abnormal ECG because of waveforms, amplitudes and electrical axis of it were variability.

  • PDF

A STUDY ABOUT ALVEOLAR CREST BONE HEIGHT BEFORE AND AFTER ORTHODONTIC TREATMENT BY USING BITEWING FILM (교익사진을 이용한 교정치료 전후의 치조골 높이 변화에 관한 연구)

  • Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.421-430
    • /
    • 1997
  • Alveolar bone grows with development of tooth germs and roots; bone deposition occurs with tooth eruption. Bone components undergoes processes of resorption and deposition, and when the balance between them is disrupted, decrease in alveolar bone height or excessive bone deposition result. It has been hon that repositioning of teeth through orthodontic treatment can cause alveolar bone resorption which result in decreased alveolar bone height, and there have been many studies to evaluate such effects. X-ray films that could be replicated and standardized were chosen in clinical studies, and among them, bitewing films were used for objective evaluation of changes in alveolar bone level. Twenty subjects, 10 to 13-year- old (average 12.2) children with Cl I molar key, healthy oral condition, no congenital missing, no periodontal disease, and pre-and post-orthodontic bitewing films, were randomly selected for comparison of alveolar bone heights. Amounts of tooth and changes in alveolar bone heights were analyzed. The following results were obtained: 1. Amount of tooth movement in canine, premolar, and molar regions, changes in tooth axis, and changes in alveolar bone heights were measured, and the mean and median values were obtained. 2. When pre-and post-orthodontic alveolar bone levels were compared, larger changes were noticed in maxilla than mandible. 3. When mesio-distally compared, larger changes were observed in the distal sides of 3D3 and 4M3, mesial sides of 4M3 and 4D3, distal sides of 4D3 and 5M3, mesial sides of 5M3 and 5D3, md distal sides of 5D3 and 6M3. 4. When the amounts of tooth movements(TX, TY)and changes in tooth axis(A) were compared,34TX, 34TY, 34A of both sides in maxilla were greater, iud changes in alveolar bone level were greater than any other region.

  • PDF

Properties of Yttrium Manganates with MFS Structure Fabricated on Various Substates (MFS 구조로 적층된 Yttrium Manganates의 기판 변화에 따른 특성 연구)

  • 강승구
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.2
    • /
    • pp.206-211
    • /
    • 2003
  • Effects of substrates and buffer layer upon the formation of crystalline phases and ferroelectricity of $YMnO_3$ thin films were investigated. The hexagonal $YMnO_3$ was easily formed on Si(100) while the mixed phases, hexagonal and orthorhombic $YMnO_3$, on $Pt(111)/TiO_2/SiO_2/Si$ substrate. When the $Y_2O_3$ buffer layer of 70 nm thick was inserted between the substrates and the $YMnO_3,$ the c-axis oriented hexagonal single phase formed on both substrates, Si(100) and $Pt(111)/TiO_2/SiO_2/Si$. The leakage current density of the hexagonal $YMnO_3$ thin films was lower than that consisting of mixed phases, hexagonal and orthorhombic. Furthermore the hexagonal $YMnO_3$ with c-axis preferred orientation showed the lowest leakage current density. The remnant polarization from a P-E hysteresis curve for the $YMnO_3$ formed on Si(100) was 0.14 without buffer layer and $0.24_{mu}C/cm^2$ for that with buffer layer. For the $Pt(111)/TiO_3/SiO_3/Si$ substrates, the specimen without $Y_2O_3$buffer layer did not show the hysteresis curve, while the buffer-layered has the remnant polarization of $1.14_{mu}C/cm^2$. It was concluded that the leakage current density and the ferroelectricity for the $YMnO_3$ thin films could be controlled by varying crystalline phases and their preferred orientation which depend on the kind of substrates and whether the $Y_2O_3$buffer layer exist or not.

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

SEMI-LONGITUDINAL STUDY ON GROWTH AND DEVELOPMENT OF CHILDREN AGED 6 TO 17 -Part III : GROWTH CHANGE OF CRANIOFACIAL HARD TISSUE (한국인 6-17세 아동의 성장과 발육에 관한 준종단적 연구 -제 3 세부 과제 : 두개 및 안면 경조직의 성장변화)

  • Hwang, Chung-Ju;Kil, Jea-Kyoung;Lim, Seon-A
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.469-485
    • /
    • 1996
  • Orthodontic patients are individuals that grow and develop ; therefore selection of the proper time for orthodontic treatment is considered to be one of most difficult and yet difficult factor. Since the development of cephalometric X-ray, amount and Pattern of craniofacial growth change with aging could be predicted and be came useful in the process of orthodontic treatment. The relationship between the mean values of cephalometric measurements and body height and weight was studied among the groups(boys and girls) of Korean children from the ages 6-years to 17-years. 409 boys and 437 girls with no abnormality in growth and development and no history of orthodontic treatment from the ages of 6 years to 17 years were chosen as subjects Cephaloment X-ray were taken for 3 years and hard tissue analysis based on Burstone's COGS, which was devided into measurements of 6 parts(Cranial base, Maxillar and Mandible, Dental measurements). The relationship between craniofacial growth and height & weight was studied. The following conclusions were obtained : 1. The maximum growth in the measurements of cranial base, N-Ar(FH), N-Ba(FH) corresponded with the age with the maximum increase in body height & weight in both boys and girls. 2. Genial angle gradually decreased with aging in both boys and girls. 3. N-ANS(L) showed greater amount of growth than ANS-Ne(L), and this had greater influence on facial profile. 4. N-A-$Pog^{\circ}$ decreased with aging, and mandibular growth exceeded maxillary growth in amount and rate. 5. Length of Y-axis Increased, but Y-axis to FH plane remained constant. This show that mandible grows at a constant angulation to cranial base. 6. As permanent teeth erupt, interincisal angle deceased.

  • PDF

Adrenal and Testicular Androgens in Serum of Men after Physical Endurance Training (격심한 운동후 남성 혈청 내 부신 및 정소 Androgen 변화)

  • Yoon, Yong-Dal;Lee, Chang-Joo;Lee, Joon-Yeong
    • Development and Reproduction
    • /
    • v.5 no.1
    • /
    • pp.73-79
    • /
    • 2001
  • Recently many studies have reported that total and bioavailable androgens reduced in male and female athletes and that physical exercise reduces the body weight and increases the reproductive abnormalities such as oligomenorrhea, anovulation, inadequate luteal phase, and delayed puberty in women by the inhibition of the hypothalamic-pituitary-gonadal (HPG) axis . In addition, high mileage endurance 겨nning, psychological stress, and military endurance training in men also reduce the secretion of reproductive hormones. To investigate the efffcts of physical endurance exercise on the secretion of reproductive hormones in men, androgenic hormones from adrenal glands and testis were measured in serum by the conventional radioimmunoassays after long-term (more than3 months), short-term (1 week), and acute (1${sim}$2 hours) physical exercises. Androgenic hormones from adrenal glands and testis such as total testosterone (TT), free testosterone (fT), dehydroepiandrosterone (DHEA), and androstenedione (A) decreased after thesestrenuous endurance trainings, whereas ACTH, cortisol, and dehydroepiandrosterone sulfetes (DHEAS) increased. Conadotropins (LH and FSH) were not idluenced by the physical exercises. Based upon the present results, we assume that the decrease in adrenal and testicular androgens by physical endurance exercises might be associated with the reproductive abnormalities in athletes by unknown factor(s) in addition to the HPG axis disturbance.

  • PDF