• 제목/요약/키워드: Ozone variation

검색결과 189건 처리시간 0.026초

김해지방의 대기오염 특성 (Characteristics of Air Pollution at Kimhae)

  • 박종길;김종필;김지형
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.33-43
    • /
    • 1999
  • This paper aims to describe the characteristics of air pollution using air pollutants concentration and meteorological data observed at Kimhae from December 1996 to November, 1997. The results are as follows : The concentration distribution of sulfur dioxide($SO_2$), carbon monoxide(CO), particulate matter(PM-10), and nitrogen dioxide($NO_2$) is high during the late fall and winter and low during the summer, but ozone concentration is low during the winter season and high during summer season except Jangma period and these distributions appear to be closely connected with insolation and the number of clear day. Diurnal variation of concentrations for sulfur dioxide, particulate matter, and carbon monoxide are high during the rush hours and nighttime and low during the daytime and these variations are distinct toward the winter season. And diurnal variation of nitrogen dioxide concentration has also same pattern and these patterns are closely related to the increasing traffic volume at rush hours. Diurnal variation of ozone concentration is generally increase for daytime and decrease for the late afternoon and are closely related to the insolation and photochemical reaction. The 24 hour average concentrations of air pollutant observed at Kimhae represented a positive correlation and a negative correlation for $O_3$ and also a negative correlation for the meteorological elements such as wind speed and cloud cover.

  • PDF

OZIPR 모델링 결과의 민감도 분석 (A Sensitivity Analysis of the OZIPR Modeling Result for the Seoul Metropolitan Area)

  • 이선화;;김용표
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.99-108
    • /
    • 2011
  • To establish area specific control strategies for the reduction of the ozone concentration, the Ozone Isopleth Plotting Package for Research(OZIPR) model has been widely used. However, the model results tend to changed by various input parameters such as the background concentration, emission amount of NOx and volatile organic compounds (VOCs), and meteorological condition. Thus, sensitivity analysis should be required to ensure the reliability of the result. The OZIPR modeling results for five local government districts in the Seoul Metropolitan Area (SMA) in June 2000 were used for the sensitivity analysis. The sensitivity analysis result showed that the modeling result of the SMA being VOC-limited region be still valid for a wide range of input parameters' variation. The estimated ozone concentrations were positively related with the initial VOCs concentrations while were negatively related with the initial NOx concentrations. But, the degree of the variations at each local district was different suggesting area specific characteristics being also important. Among the five local governments, Suwon was chosen to identify other variance through the period from April to September in 2000. The monthly modeling results show different ozone values, but still showing the characteristics of VOCs-limited region. Limitations due to not considering long range transport and transfer from neighbor area, limitation of input data, error between observed data and estimated data are all discussed.

네온방전관형 오존발생기의 방전특성 및 오존생성특성에 관한 연구 (A Study on the Characteristics of Discharge and Ozone Generation for Ozonizer of Neon Discharge Tube Type)

  • 송현직;우성훈;김상구;김기채;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1857-1860
    • /
    • 1996
  • In this paper, ozonizer of neon discharge tube type( Neolamp ) by using silent discharge has been designed and manufactured. The discharge and ozone generation characteristics of Neolamp have been studied with variation of turn-on number( N ) of Neolamp, quality( Q ) and shape of external electrode. The discharge voltage is proportional to gap spacing of spiral external electrode( G ) for constant applied volatge. The discharge current is inversely proportional to G for constant applied volatge. The ozone concentration is inversely proportional to Q and G. Also, ozone concentration and generation are proportional to N. The sterilization characteristics of Escherichia coil have been obtained more than 97[%] at $1.30[mg/{\ell}]$ of liquid ozone concentration.

  • PDF

과거 30년 우리나라 광화학 오염과 연구 현황 (Photochemical Air Pollution of Seoul in the Last Three Decades)

  • 한지현;김학영;이미혜;김소영;김세웅
    • 한국대기환경학회지
    • /
    • 제29권4호
    • /
    • pp.390-406
    • /
    • 2013
  • In Korea, photochemical air pollution has drawn public attention as one of the major environmental issues since 1990s. To abate ozone and air pollution, new legislation was enacted and regulation was reinforced in conjunction with basic researches. As a result, the air quality has been much improved in terms of primary pollutant such as CO and the occurrence of extremely high ozone concentration. In Seoul, on the other hand, concentrations of ozone and exeedance hours of its national standard have increased since 2005, which is intimately coupled with $NO_2$ variations. It indicates the need for further research at long-term bases to improve our understanding on complex processes determining ozone concentrations. In this paper, the characteristics of ozone variation was analyzed with 13-year measurement data obtained in Seoul. In addition, the previous studies and their main results were summarized that have been performed in association with photochemical air pollution in Korea over the last three decades.

고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화 (Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation)

  • 이진국;이효영;임인철;유윤식
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.171-180
    • /
    • 2016
  • 본 연구는 고 에너지 방사선 조사에 기인된 방사선치료실 내 오존 농도의 변화를 비교 분석하고자 하였다. 이를 위하여 치료실 주변 대기 중 오존 농도와 치료실 내 배경 오존 농도를 분석하여 고 에너지 방사선 조사에 기인된 치료실 내 평균 오존 농도를 비교하였다. 치료실 내 배경 오존 농도는 평균 $17.4{\pm}7.9ppb$로 방사선치료실 주변의 대기 중 오존 농도(평균 $36.8{\pm}22.3ppb$)보다 약 50% 정도 통계적으로 유의하게 낮게 나타났다(p<0.05). 고 에너지 방사선 조사에 기인된 치료실 내 오존 농도는 방사선이 조사됨과 동시에 배경 오존 농도의 약 2배 수준으로 급격하게 증가되었으며 조사시간이 증가함에 따라 기울기가 일정한 증가 추이를 보이다가 약 130초에서 180초 부근에서 최대 오존 농도를 이루고 점차 포화되는 경향을 보였으며 배경 오존 농도로 감소하는데 소요되는 시간은 약 10분 이상이었다. 본 연구 결과를 토대로 고 에너지 방사선 조사에 기인된 방사선치료실 내 오존 농도는 후각을 자극하는 오존의 특이한 냄새를 맡거나 순간적인 호흡 곤란과 마른기침으로 가슴 통증 등의 신체적 증상이 나타날 수 있는 수준으로 밀폐된 방사선치료실에서 고농도 오존에 장시간 노출될 경우 폐 질환을 악화시킬 수 있기 때문에 각별한 주의가 요구된다.

서울시 대기중 오존오염도의 연도별 변화와 그 영향인자 분석: 광화문 지역을 중심으로 (Yearly Variation and Influencing Factors of Ozone Concentration in the Ambient Air of Seoul)

  • 이기원;권숙표;정용
    • 한국대기환경학회지
    • /
    • 제9권1호
    • /
    • pp.107-115
    • /
    • 1993
  • This study was carried out to find the characteristics of surface ozone concentration data obtained during 1988-1991 by the Korea Ministry of Environment. Seasonal data (spring, summer, autumn and winter) wre obtained in May, August, November and February respectively at Kwanghwamun in Seoul. The pollutants analyzed in this study are $SO_2, TSP, CO, NO, NO_2 and NO_2/NO$. Atmospheric factors such as solar radiation, wind speed, relative humidity, cloud amount and atmospheric temperature are also analyzed. The influence of pollutants and atmospheric factors that affect ozone concentration were analyzed by statistical method. The results are summarized as follows : 1. The ozone concentration varied seasonally. The maximum values were 23 ppb in spring, 33 ppb in summer, 16 ppb in autumn and 13 ppb in winter. So the seasonal ozone value was highest in Summer. 2. Te diurnal concentration of ozone was highest during 2-4 P. M. and was very low in the morning and evening. 3. The maximal correlation coefficients of each season between ozone concentration and the influencing pollutants or atmospheric factors asr as follows ; a. spring, r = 0.44(solar radiation) b. summer, r = -0.59(relative humidity) c. autumn, r = -0.55(relative humidity) d. winter, r = -0.58($NO_2$) 4. The major factor affecting the ozone concentration in spring was solar radiation, Relative humidity was the first affecting factor in summer, autumn and $NO_2$ concentration was dominant in winter.

  • PDF

이어도 해양과학기지의 오존농도의 계절변화와 일변화 특징 (Seasonal and Diurnal Variations of Surface Ozone at Ieodo in the East China Sea)

  • 신범철;이미혜;이재학;심재설
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.631-639
    • /
    • 2007
  • We examined diurnal and seasonal variations of ozone ($O_3$) concentrations and its relation to meteorological parameters observed at the Ieodo Ocean Research Station ($32.07^{\circ}N$, $125.10^{\circ}E$, 36 m above sea level) during June 2003 and May 2005. Over the 2-year period, the mean ozone concentration was $49.5{\pm}15.5\;ppbv$. Ozone concentrations show great variability with a monthly mean up to 68.2 ppbv in May 2005 and seasonal variations with being highest in spring and fall, and lowest in summer. However, the amplitude of diurnal variation was less than ${\sim}4\;ppbv$ with a maximum at $3{\sim}4\;p.m.$ and minimum at $7{\sim}8\;a.m.$ HYSPLIT backward air trajectory indicated that the air masses with higher ozone came from the north or northwest and those with lower ozone arrived mainly via southerly or southeasterly. Ozone distributions at Ieodo Ocean Research Station were observed to be significantly impacted by long-range transport and regional scale air circulation.

한국의 시골지역에서의 오존농도의 특성 (Characteristics of Ozone Concentration in the Rural Area of Korea)

  • 정용승
    • 한국환경과학회지
    • /
    • 제4권1호
    • /
    • pp.63-70
    • /
    • 1995
  • 1993년 7월부터 1994년 6월까지 1년간 시골지역에서 지면 부근의 오존을 연속적으로 측정하여 5분 평균치를 연구에 이용하였다. 이 관측은 북위 $37.4{\circ}$, 동경 $127.6{\circ}$ 에 위치한 충북 청원군 강내에서 실시되었으며, 1년 평균값은 17ppbㅠ이고 월평균은6-47ppb이다. 여름에 최대값이 발생하고 겨울에 최소값이 나타나며, 이들은 인위적인 배출물 및 광화학 반응과 관련이 있따. 오존으 일변화는 15:00~16:00시에 최대치와 07:00~08:00시에 최소치가 발생한다. 오존이 80ppb이상 발생하는 기간에는 북-북서풍의 안정한 기류가 유입할때 발생하는 반면, 여름에 오존이 매우 낮게 발생하는 기간에는 북태평양에서 유입되는 기류와 함꼐 발생하였다. 그러므로 장거리에 근원을 둔 인위적인 대기오염의 이동(LRTAP)이 시골지역의 국지적인 오존의 발생보다 더 큰 기여를 하고 있음을 시사한다.

  • PDF

한반도를 포함한 동아시아 영역에서 오존전량과 유해자외선의 특성과 예측 (Characteristics and Prediction of Total Ozone and UV-B Irradiance in East Asia Including the Korean Peninsula)

  • 문윤섭;민우석;김유근
    • 한국환경과학회지
    • /
    • 제15권8호
    • /
    • pp.701-718
    • /
    • 2006
  • The average ratio of the daily UV-B to total solar (75) irradiance at Busan (35.23$^{\circ}$N, 129.07$^{\circ}$E) in Korea is found as 0.11%. There is also a high exponential relationship between hourly UV-B and total solar irradiance: UV-B=exp (a$\times$(75-b))(R$^2$=0.93). The daily variation of total ozone is compared with the UV-B irradiance at Pohang (36.03$^{\circ}$N, 129.40$^{\circ}$E) in Korea using the Total Ozone Mapping Spectrometer (TOMS) data during the period of May to July in 2005. The total ozone (TO) has been maintained to a decreasing trend since 1979, which leading to a negative correlation with the ground-level UV-B irradiance doting the given period of cloudless day: UV-B=239.23-0.056 TO (R$^2$=0.52). The statistical predictions of daily total ozone are analyzed by using the data of the Brewer spectrophotometer and TOMS in East Asia including the Korean peninsula. The long-term monthly averages of total ozone using the multiplicative seasonal AutoRegressive Integrated Moving Average (ARIMA) model are used to predict the hourly mean UV-B irradiance by interpolating the daily mean total ozone far the predicting period. We also can predict the next day's total ozone by using regression models based on the present day's total ozone by TOMS and the next day's predicted maximum air temperature by the Meteorological Mesoscale Model 5 (MM5). These predicted and observed total ozone amounts are used to input data of the parameterization model (PM) of hourly UV-B irradiance. The PM of UV-B irradiance is based on the main parameters such as cloudiness, solar zenith angle, total ozone, opacity of aerosols, altitude, and surface albedo. The input data for the model requires daily total ozone, hourly amount and type of cloud, visibility and air pressure. To simplify cloud effects in the model, the constant cloud transmittance are used. For example, the correlation coefficient of the PM using these cloud transmissivities is shown high in more than 0.91 for cloudy days in Busan, and the relative mean bias error (RMBE) and the relative root mean square error (RRMSE) are less than 21% and 27%, respectively. In this study, the daily variations of calculated and predicted UV-B irradiance are presented in high correlation coefficients of more than 0.86 at each monitoring site of the Korean peninsula as well as East Asia. The RMBE is within 10% of the mean measured hourly irradiance, and the RRMSE is within 15% for hourly irradiance, respectively. Although errors are present in cloud amounts and total ozone, the results are still acceptable.

중첩방전형 오존방생기의 특성(III) (Characteristics of a Superposed Discharge Type Ozonizer(III))

  • 송현직;이광식;이동인;김기채;이동헌;김금영;이춘하;전영주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1815-1817
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer(IESDO) has been designed and manufactured. IESDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quantity of supplied gas and discharge voltage (2) the characteristics of ozone generation with variation of quantity of supplied gas, discharge power, operating number of IESDO.

  • PDF